ACT20M Presentation - Weidmuller B2B Portal
Download
Report
Transcript ACT20M Presentation - Weidmuller B2B Portal
ACT20M
6mm Signal Isolators and Converters
ACT20M – 1 & 2 channels in 6mm width !
Phase 1…..10 models – isolators & converters
Power rail option – minimizes cabling time
Hazardous approvals (Class 1 Div 2, Zone 2 ATEX)
Includes 2 channel options – in 6mm width !
DIP switch settable - except UI (computer configurable)
Wide ambient -25 to 70C
part no.
1176070000
1176080000
1176040000
1176050000
1176030000
1175980000
1176000000
1176010000
1175990000
1176020000
Description
ACT20M-CI-CO-ILP-S
ACT20M-2CI-2CO-ILP-S
ACT20M-CI-CO-OLP-S
ACT20M-2CI-2CO-OLP-S
ACT20M-UI-AO-S
ACT20M-CI-CO-S
ACT20M-AI-AO-S
ACT20M-AI-AO-E-S
ACT20M-CI-2CO-S
ACT20M-AI-2AO-S
ACT20M training
Function
1 channel passive current isolator
2 channel passive current isolator
1 channel OLP isolator
2 channel OLP isolator
Universal input converter/isolator
1 channel current isolator
1 channel convertor/isolator - DIP selectable
Economy Convertor/isolator - DIP selectable
Current Splitter/isolator
Current/voltage Splitter/isolator
Power
Input loop
Input loop
Output loop
Output loop
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Auxiliary
Page 2
From MAS to ACT20M….
Questions and Answers
What does the name mean?
ACT20M
Analog Conditioner Transmitter IP20 Micro
Why a new product family?
ACT20M replaces and expands the existing
MICROANALOG series – the functionality of which is
limited by having only 6 terminals. ACT20M has 8.
Will MAS range be replaced?
Some overlap exists - but probably not, as ACT20M is for
process customers, whereas MAS has been mainly for
factory / machinery customers.
When will ACT20M products be available?
There are 10 variants. End November 2011 we have 6
variants in Richmond stock.
Seite 3
ACT20M training
More performance in 6mm !
Expansion with 3 new functions
Dual OLP Isolators,
Universal Converter in 6mm,
Aux powered Splitters
Replacement and Improvement
of the existing MAS DC/DC select
Splitter with sensor supply
- Aux power permits power
for 2-wire transmitter
Wide temperature range:
-25…+70°C operating temperature
High galvanic isolation
300 V rated voltage,
2,5 kV test voltage
Worldwide application
international approvals cULus,
ATEX Zone 2, FM-Div. 2,, GL, DNV
Quick and easy configuration
by DIP-Switches or FDT/DTM
Software
Power supply via DIN-Rail-Bus
24 V supply via DIN-Rail
Seite 4
ACT20M training
High accuracy
of up to 0,05%
Who are the target customers for ACT20M?
Process Industries, e.g….
Oil & Gas (Production and transmission)
Chemicals and Petro-chem
Power, Paper & Pulp
Iron & Steel, Cement
Customers are:
Systems Integrators
Plant end-users (above)
Package plant OEMs (separators, dryers, coolers, effluent
treatment, chemical dosing, pumping)
Page 5
ACT20M training
How does ACT20M compare?
Weidmuller
Phoenix
Red Lion
Omron
WAGO
ACT20M
MINI MCR
AIMA/IAMA/AFCM
K3FP Series
Series 857
10
14
3
10
9
Screw / Tension
Screw
Screw / Tension
Screw
Screw
Tension
Power rail option
Yes
Yes
No
Yes
No
Approvals - Normal
cULus, CE, DNV, GL
cULus, CE, GL
cULus, CE, GL
UL 508
CE, cULus, GL (pending)
Approvals - Hazloc
FM Div2, ATEX Zone 2
Typ. FM Div2
Typ. FM Div2
None
Div 2
-25 to 70C
-20 to 60C
-20 to 60C
-20 to 65C
-20 to 70C (/50C)
2.5kV
1.5kV
1.5kV
1.5kV
2.5kV
No. of models
Ambient temperature
Isolation
ACT20M training
Page 6
Typical application – ACT20M-AI-2AO-S
Hazardous Area
Safe Area
Division 2 or Zone 2 area
Power supply, e.g.
CP T SNT 90W 24V 3.8A
a.c.
Local display DI350
Remote PLC
DC power for tx
P S
+
0–5V output 1
4-20mA input from tx
Level
transmitter
Input
O/P 1
O/P 2
PLC and display
have passive
inputs
4-20mA output 2
ACT20M-AI-2AO-S
Use where the splitter’s
receivers have passive
inputs
ACT20M training
Page 7
Typical application – ACT20M-CI-2CO-S
Hazardous Area
Safe Area
Division 2 or Zone 2 area
Power supplies,
e.g. CP T SNT 90W 24V 3.8A
Local loop-powered
display DI350
Remote PLC
P S
4-20mA output 1
4-20mA input from tx
Level
transmitter
Input
O/P 1
O/P 2
PLC and display
have passive
inputs
4-20mA output 2
ACT20M-CI-2CO-S
Use where all signals are mA,
and the isolator’s receivers
have passive inputs
ACT20M training
Page 8
Typical application.... ACT20M-CI-CO-S
Control room PLC
+24Vdc
+24Vdc
In-head
2-wire tx
DC Power
Supply
DC power for tx
Passive input
P S
4-20mA
4-20mA
Input
O/P
Heat exchanger
ACT20M-CI-CO-S
Use where the field devices are
separately powered and the PLC
has a passive input.
ACT20M training
9
Typical application.... ACT20M-AI-AO-S
Control room PLC
+24Vdc
DC Power
Supply
DC power for tx
In-head
2-wire tx
P S
+17V
4-20mA
0-20mA
Input
O/P
ACT20M-AI-AO-S
Use where the field devices can
be powered from the isolator, and
the PLC has a passive analog
input.
Heat exchanger
ACT20M training
10
Typical application.... ACT20M-AI-AO-E-S
Control room PLC
Level tx
+24Vdc
+24Vdc
DC Power
Supply
P S
4-20mA
0-10V
Input
O/P
ACT20M-AI-AO-E-S
Use where mA/Volts conversion
is needed, the field devices are
separately powered, and the PLC
has a passive analog input.
ACT20M training
11
Typical application - ACT20M-UI-AO-S
Hazardous Area
Division 2 or Zone 2 area
Controller
+24VDC
3-wire
Pt100 probe
P S
Passive input
channel
4-20mA output
Input
O/P
ACT20M-UI-AO-S
Use where a mixture of inputs / converters are
needed (thermocouples, RTDs, Volts, mA) and
the receivers have passive inputs
Heat exchanger
ACT20M training
Page 12
Typical application – ACT20M-CI-CO-OLP-S
+24Vdc
DC Power for
field
instruments
Controller
+24Vdc
Active input cct –
powers the input
device
4-20mA
proportional to
flow
P S
I/P
4-20mA
Input
O/P
ACT20M-CI-CO-OLP-S
Flow Transmitter
2-wire, 4-20mA
Use where the field device is
separately powered and the
isolator is to be powered by it’s
receiver.
Process vessel
ACT20M training
Page 13
Typical application – ACT20M-2CI-2CO-OLP-S
Class 1 Division 2 or Zone 2 Area
Hazardous Area
Safe Area
+24Vdc
DC Power for
field
instruments
Active input ccts
– powers input
devices
4-20mA signals
proportional to
flow &
temperature
Controller
P S
I/P 1
4-20mA
Temperature transmitter
2-wire 4-20mA
Input
I/P 2
O/P 1
O/P 2
4-20mA
ACT20M-2CI-2CO-ILP-S
Flow Transmitter
2-wire 4-20mA
Use where the field devices are
separately powered and the
isolator is to be powered by it’s
receiver.
Process vessel
ACT20M-CI-CO-OLP-S
ACT20M training
Page 14
Typical application – ACT20M-CI-CO-ILP-S
+24Vdc
DC Power for
field
instruments
Controller
4-20mA
proportional to
flow
P S
I/P
Process vessel
Input
O/P
ACT20M-CI-CO-ILP-S
Flow Transmitter
2-wire 4-20mA
ACT20M training
Use where a separate isolator
power supply is not available,
or where the isolator is added
to the loop later.
Page 15
Typical application – ACT20M-2CI-2CO-ILP-S
Class 1 Division 2 or Zone 2 Area
Hazardous Area
Safe Area
+24Vdc
DC Power for
field
instruments
4-20mA signals
proportional to
flow &
temperature
Temperature transmitter
2-wire, 4-20mA
Controller
Passive input ccts
P S
I/P 1
Input
I/P 2
O/P 1
O/P 2
ACT20M-2CI-2CO-ILP-S
Flow Transmitter
2-wire, 4-20mA
Use where a separate isolator
power supply is not available,
or where the isolator is added
to the loop later. Receivers
should have passive inputs.
Process vessel
ACT20M-CI-CO-ILP-S
ACT20M training
Page 16
Seite 17
ACT20M training