Recommended PdMs Prior To Shutdown
Download
Report
Transcript Recommended PdMs Prior To Shutdown
Recommended PdMs Prior To Shutdown
• Visual Inspection
• Vibration
Wear in bearings, gears, belts
Alignment of rotating components
Balance of machines and loads
Lubrication of bearings
Looseness - mounting and wear
Resonances – naturally occurring
• Infrared
MCC electrical components and connections
Rotating machines, loads and mechanical connections
Transformers
• Bearing Discharge
VSD motors
Recommended PdMs Prior To Shutdown
• Power & Current Signature Analysis (CSA)
Motors for SF overloading, rotors, mechanical issues & start up issues
VSDs and Soft Starts
Transformers
Generators
PF measurement
• Ultrasound
MCC electrical components and connections
Air Leaks
• Partial Discharge (≥ 4 kV only)
MCC electrical components and connections
Motors
Generators
Transformers
• Oil Analysis
Transformers
Recommended PdMs During Shutdown
• Visual Inspection
• Electric Circuit Analysis
Motors & motor auxiliary components
Feeder cables
Motor rotors if problem suspected
Generators
Capacitors
• Insulation Assessment (IR, PI, Hipot, Impulse & PD)
MCC electrical components
Motors
Generators
Transformers
Cables
Torq Reliability Services Delivery Methods
1. Train & mentor your staff
2. Data Analysis of data collected by your staff
3. Supplemental Field Services during shutdowns or
extraordinary circumstances
4. Turn Key Field Services including data collection
and analysis per schedule
Torq Technical Expertise – 1 of 3
• Insulation Assessment
Insulation Resistance/Polarization Index
DC High Voltage
AC Line Frequency High Voltage
VLF High Voltage
High Voltage Impulse/Surge
Off-Line Partial Discharge with Hipot and Impulse
On-Line Partial Discharge
Tan δ/Power Factor
• Current Signature Analysis
Rotor Diagnostics
Load Diagnostics – Fans, pumps, conveyors, etc
Start Up Problems – Drives, Soft-Starts, Switchgear, etc.
Mechanical Diagnostics – bearings, gearboxes, etc
Torq Technical Expertise – 2 of 3
• Electric Circuit Analysis
Resistance
Inductance/Impedance
Capacitance
Rotor Influence Check (RIC)
• Power Analysis
Power quality
Voltage transients
Process optimization
• Visual Inspections
• Infrared Thermography
Torq Technical Expertise – 3 of 3
• Ultrasound Surveys
Leaks
Bearing arcing
Electrical discharge
• Efficiency Estimation
• Consulting
Data analysis
Root cause
Training/ Mentoring
•
Partner with other companies to perform
mechanical services: vibration, oil analysis,
alignment and balancing.