Acces Modular Controller

Download Report

Transcript Acces Modular Controller

ACCESS CONTROL
Sistem yang berfungsi untuk mengatur hak akses ke suatu area tertentu pada waktu
tertentu
PT.Danatel Pratama
1
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
Pengenalan Master Control Panel
Sistem pengamanan acces control terdiri dari beberapa komponen antara lain :
Controller devices:
Identification devices:
Output devices:
PT.Danatel Pratama
2
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
 4 Wiegand Interface Include the reader power supply
 Standard 64 MB compact Flas – extendeble to 1 GB
 LCD display for displaying information
 Max 200,000 cardholders with AMC CF-1024 (MB) additional memory
Host Interface
 RS 485 (2 –or 4-Wire): opto-decopled
 RS 232
 Ethernet 10/100BaseT (TCP/IP)with RJ45











Design harmonized with AMC and I/O board
rail mountable
charging unit included
Nominal output power 60 W
Nominal output voltage 12 V and 24 V
Input voltage range 100 Vac to 240 Vac
Battery support up to 14 Ah
Short circuit protection
Over voltage protection for the load
Regulation of battery charging voltage with extern NTC-resistor
Signaling for AC-OK, DC-OK, BAT-OK and BAT-operation
PT.Danatel Pratama
3
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
AMC2 System Components
power
supply with
charging
unit
AMC 2.0
Compact
Flash
Memory
PT.Danatel Pratama
4
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.

I/O module
Proximity Reader
Apa itu acces modular Controller (AMC):
 Compact state of the Acces Controller with intergrated LCD
 Extendedable Wiegand Channel And I/O Wiith compact consoles
 Operator bought standalone as IP-or serial connected to Host PC
 For Low-End Up to High – end solution (dep. On Host software)
PT.Danatel Pratama
5
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
AMC Product family overview
AMC2 4W-Net-CF
AMC2 161-160-EXT
AMC2 81-80-EXT
AMC2 4R4 - CF
AMC2 ENC-UL1
AMC2 ENC-UL2
PBC-60
AEC-AMC-VDS1
PT.Danatel Pratama
6
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
Acces Modular Controller (AMC)
 There are two type of AMC controllers:
• The AMC2 4W – NET-CF whith can cannet up to 4 Wiegant
card redars
• The AMC2 4R4-CF which can connect up to 8 card redars via
RS-485 OSDP/HADP protocol
AMC2 4W-Net-CF
AMC2 4R4 - CF
PT.Danatel Pratama
7
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
Acces Modular Controller (AMC)
 Support up to 4 wegan card reader channel (AMC2 4W-NET-CF)
• Supporting iClass, EM, Mifare and compatible reader with
Wiegant interface
• Auto-assigned to corresponding Door tamplate including the
inputs and outputs
 Support up to 8 card seriar HADP reader (AMC2 4R4-CF)
• Supporting RS – 485 HID HADP readers
PT.Danatel Pratama
8
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
Acces Modular Controller (AMC2)
 Ethernet and serial host interface to server
 Support DHCP
 Password protected acces for setup
 Display with step-though-button for perfect device status
overviem
 Standard DIN rail-mountable
PT.Danatel Pratama
9
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
Acces Modular Controller (AMC2)
 RS485 bus for Wiegand – and/or I/O extension support
 2-and 4-state operation on input with software selectable terminstors
 Compact flash card memory to store cardholders/events
 Default 2GB CF card
 When operating offine you can save up tp 20,000
cardhoders and 992 events per cardholder
 Internal, offine capable
associations ofState and events to
triger outputs,such as trigger
buzer when door open time is
exceeded
 CE approval
PT.Danatel Pratama
10
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
Acces Modular Controller (AMC2)
AMC2 4W-NET-CF (Wiegand reader)
PT.Danatel Pratama
11
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.
AMC 4R4-CF (RS-485 Bus readers)
Connecting the card reader to Controller (AMC2)
AMC2 4W-NET-CF with Weagand readers
 The max. cable length between devices may not axceed 150 meters at
ideal conditions.
 Per divice connection mi. 6 wire are necessary
 The devices are connected/wire 1:1 with the acces control panel (no bus
system)
 Max. 4 devices can be directly connected to an AMC control panel.
PT.Danatel Pratama
12
Office Park LOT18 5 Floor Tower A-SCBD Jl.Jend.Sudirman Kav.52-53 Jakarta 12190
Telp: 021-5152636 Fax 021-5152635 / 021-5151904.