Introduction
• Working on getting summaries and info out of tkLayout for services
• Under development (not debugged, not updated)
• Used as reference among detector, electronics and mechanics designers ,
to assist communication and decision-making
• Not to compare ‘1-1’ now but to trigger conversation for comparison
(offline).
• Code can be used for different pixel geometry configurations w/o
modification
• Contents of the talk:
– First part : introducing the new summary tab added and pointing out what needs
to be updated / discussed
– Second part : some useful plots
• http://sorfanel.web.cern.ch/sorfanel/layouts/OT_Tilted_362_200_Pixel_4
021/Electronics.html
2
Introduction to the tklayout webpage
Geometry (pixel)
tab:
Already existing
Containing info for
layers, disk and
modules but not in
a convenient way
for services
summaries
3
Introduction to the tklayout webpage
Material (pixel)
tab:
Already existing
Containing info for
radiation length
and inetraction
length maps and
services ID map.
4
Services ID map
OptoConversion
L1, L2, L3, L4
OptoConversion
FPIX2_#1-#4
OptoConversion
FPIX1_#1-#7
Barrel Layer 4
Barrel Layer 3
Barrel Layer 2
Barrel Layer 1
FPIX1_#1-#7
FPIX2_#1-#4
5
New entry: tab for pixel electronics
“electronics”:
One csv file with Services
info.
Three identical tables
(one after the other):
Barrel, FPIX1, FPIX2
6
New tab for pixel electronics info:
“electronics”
7
Services{…}.csv file description:
Emphasis on TWP, HV, SP, Cooling
Number from
Service ID
Map
HV, SP,
Cooling or
TWP
(for fibers,
support:
blank)
Barrel
layer or
type of
FPIX disk
for HV,
SP,
Cooling,
Barrel
layer or
ring for
TWP
Length
[mm
ElementName
Mass [g]
Coordinates
Mass per
length
[g/mm]
Radiation
length
Interaction
length
8
Barrel Table Part #1:
geometry description
Reshuffling
information that
was already in the
geometry tab
• 12 rods of 9 modules of 1x2 (L1,L2) or 2x2(L3,L4)
• 25x100 used along all layers
9
Barrel Table Part #2:
Example of powering description
[*] are variables that
will be modified.
Not to be trusted
now.
SP cable Xsection
had been optimized
by for old chip power
numbers
•
•
•
around 10% average digital
power variation standard
trigger and hits vs only clock
Not including power for
readout
RD53A last week: Sara Marconi
https://indico.cern.ch/event/5
67361/
10
Barrel Table Part #2:
Powering description
[X] SP RULES BROKEN
BY GEOMETRY
Incompatible with
chip capabilities
•
Reminder of “SP rules” as summarised by Charles [July’s tracker week,
https://indico.cern.ch/event/548644/]
– Maximum length of SP chain: 8clusters
– BPIX rods/FPIX Dees/FPIX rings/FPIX rings side independent from each other
– SP chains can be made of “clusters” that can be modules 1x4 or 2x2 with chips on
module parallel powered or Two Modules of 1x2 each, parallel powered.
• The reason why is that for the moment there is no protection foreseen and
only the failure scenario of 1 out 4 chips (meaning the rest will need to carry
32%Ichain extra current) has been studied. There is no guarantee that a chip
11
can carry 100% extra current.
E-links info &
Summary of Services weights
[mm]
• Info for GBT/#links/speed etc
• Summary of services weights [gr] per layer (per Z-end)
• Other information that could be useful?
12
FPIX example summary table
[X] Differences on
services info:
• SP, Cooling and
HV are distributed
homogeneously
on disks. No ring
information.
• TWP per ring info
13
Part #2
• Services plots for OT_Tilted_362_200_Pixel4021
• Currently these plots are not generated
automatically
• Working on making another tab with this kind of
plots
14
Length of TWP [mm] per Z end
Twisted Pairs Length distribution
• Although L4 at higher radius, the length till the optoconversion dominates.
• Min ~400cm and max ~550cm BPIX TWPs.
• Very short distances for FPIX TWPs.
15
Total Services radiation length
Cooling
High Voltage
Serial Powering
Twisted pairs
0.06
0.05
0.04
0.03
0.02
0.01
0
0
0.5
1
1.5
2
2.5
3
3.5
4
h
• TWPs dominate 0<η<1, η>3
• Cooling has improved since moving to Titanium
16
TWP radiation length
0.05
Twisted pairs [all]
Twisted pairs FPIX
Twisted pairs L4
Twisted pairs L3
Twisted pairs L2
Twisted pairs L1
0.04
0.03
0.02
0.01
0
0
0.5
1
1.5
2
2.5
3
3.5
4
h
17
Barrel Layer 1 Services
Cooling
High Voltage
Twisted pairs
Serial Powering Lines
0.025
0.02
0.015
0.01
0.005
0
0
0.5
1
1.5
2
2.5
3
3.5
4
h
18
Next steps:
• Call for feedback
• Next steps:
–
–
–
–
Converge on number for power+ chains
Update ROC Power numbers
Fill in FPIX info for services
Add Fiber info in the summary table
• Currently only on the csv summary
– Radiation length plots
• Currently manually
– Debug and release this version of the code
19
Power&Fiber.xlxs by Corenll