Industrial Radiography Supplies and Services Inc. (IR), located in
Edmonton Alberta, Canada, is in its first years of operations and has
become the leading supplier of RT products in Western Canada.
IR’s vision for the future will be to expand into other NDE disciplines
and develop an educational center focusing on radiation safety and
product training. IR will also become a leader in digital technology
working with those companies that are willing to help us develop
products that will perform under Western Canada’s unique climate and
production techniques.
Analog Vs Digital
Displays
Analog
Digital
DMC 2000-SOR/R
PEN Dosimeter
RDS 30
Canadian Admiral
RadEye G
Dosimeter Displays
Different models have Different
Ranges and are displayed using
different scales
Digital models have an easy to read
display that goes from 0.1mR to
1000R and can with the push of a
button can even display the rate as
a double check to a survey meter
Response Time Comparison
Set Up
Dose Rate = 600mR/hr
Distance to Center of Detector = 11.79”
D(inches) = 22.2(mCi/mRhr)ˆ½
Activity of reference Source
Cs-137, s/n S1307
on October 27, 2008
= 168.88 mCi
Analog
Canadian Admiral
Model CCD-100-10
S/N 02085
Display not scaled with
proportional increments,
makes it hard to read
current field strength at a
glance
Jumps between 500mR/hr
and 700mR/hr
Meter set on high scale If
on low, the scale range
would have to be changed
manually by the user
Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity
168.89mCi
Digital
RDS 30
S/N 270700
Scale range is automatic
and requires no user
intervention
Display easily read
Stable Field
Measurement
Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity
168.89mCi
Direct Response Time Comparision
RDS 30
S/N 270700
Canadian
Admiral
Model CCD100-10
S/N 02085
Note:
Canadian
Admiral set
on Low Scale
Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity
168.89mCi
Direct Response Time Comparision
RDS 30
S/N 270700
Canadian
Admiral
Model CCD100-10
S/N 02085
Note:
Canadian
Admiral set
on High Scale
Actually footage taken at IRSS using a Cs-137(NIST Traceable) source with current activity
168.89mCi
Meter Status Screenshot
Dose Rate Alarm Set-Up Screen- Using Wireless
IRDA Connection to Communicate with PC
History Reading Screenshot
Dose Alarm Set-Up Screen- Using Wireless IRDA
Connection to Communicate with PC
PC Interface Screenshot
SOR/R Overview
General Features
•
•
•
•
•
•
•
•
Solid State (silicon diode) detector
Personnel & Area Monitoring capability
Linear response to 1000 R/hr
Energy Range: 50 keV - 6 MeV
Self Testing/Diagnostics (battery, detector)
Internal Memory “Histogram”
Standard Calculator Battery - over 2000 hrs
Multi-Configuration:
- Dose, Rate and Time Alarm/Warning
- Satellite or Autonomous operation
- Hands-Free communication
SOR/R Overview
General Features
•
Alarm Thresholds
- Primary Alarm for Dose and Dose Rate
- Pre-Alarms (warnings) for Dose and Dose Rate
•
Histogram – “Events History”
- 700 intervals
- 10 sec, 1 min, 10 min, 1 hr, 24 hr
- Stamps dose increment, date, time at selected time interval;
records alarm or error indication automatically
SOR/R Overview
General Features
•
Optical Detector Check
- Expose diode to light source every 10 minutes
- Three consecutive failures, detector fault alarm (def det)
Test-to-failure concept!
•
Background Radiation check
- 10 uR/hr: one pulse ~ 10 minutes
- No counts in pre-determined time: det. Fault
•
Battery (voltage)check every 10 minutes
Display Messages – Internal Faults
Defective Detector:
Defective Calibration:
Defective History:
Defective Component
for Pulse Counting:
Remove from service
Return for repair/replacement
Start new histogram using
Reader – Entry/Exit
Defective Battery:
Battery discharged/removed;
Change battery, check for short
Or defective ground wire
Defective EEPROM:
Problem accessing data in
Memory; remove battery for
72 hrs,reinstall
Drained Battery:
Remove battery for 72 hrs;
inspect for damage
Calibration data integrity
problem; re-calibrate
dosimeter
Remove from service; return
For repair/replacement
Defective External
Detector/Initialization:
External detector calibration
value corrupted; Data integrity
suspect or corrupted; reinitialize calibration or system
parameters. Contact
MGPI for help
History
Customizable Alarm/Alarm Warning
Thresholds
Audible Alarms and Warnings Have
Different Tone
Dose and Dose Rate thresholds Have
Different Audible Tones
History
Time Stamp- Can be set to record
down to an interval of every 10
seconds
Detailed Graph- allows user to
display and calculate dose
increments down to an interval of
every 10 seconds
Records can be electronically saved
or printed
In Development
New Designs to meet user
preferences and demands
New Technology can be used in
traditional designs
ALARA and
Safety Advantages
Digital Survey Meters
Digital Survey Meters do not need to be adjusted by the user to change scales
Customizable audible alarm thresholds
Digital Dosimeters
Digital Dosimeters display instantaneous, easy to read and accurate dose levels
Digital Dosimeter History reports can be analyzed, saved electronically, and matched to TLD
reports
Customizable audible alarm thresholds
Have a scale going up too 1000R, Dose will not run meter off scale