Bluetooth Wireless Solution Sales Presentation

Download Report

Transcript Bluetooth Wireless Solution Sales Presentation

Wireless Solutions Overview
January 18, 2017
Douglas Lighting Controls
1
Company Confidential
Channel Notice
• Product Specification (electrical and mechanical) is subject to
change without notice. Information provided is directional
only and does not constitute an offer of sale to the market.
• Patent(s) Pending
• The Bluetooth® word mark and logos are registered
trademarks owned by Bluetooth® SIG, Inc. and any use of
such marks by Panasonic is under license.
2
Company Confidential
Outline
•
•
•
•
•
•
Douglas Lighting Controls Bluetooth® Fixture Controller & Sensor
Douglas Lighting Controls Bluetooth® Controller
Douglas Lighting Controls Bluetooth® Sensor
Douglas Lighting Controls Bluetooth® Switches
Douglas Lighting Controls Bluetooth® Dialog Gateway
Architecture
3
Company Confidential
Douglas Lighting Controls Bluetooth® Fixture Controller & Sensor
• Automated Fixture Control > For Parking Garages, Warehouses….
•
•
•
•
Upgrade existing or add to new fixtures
Meet Energy Code requirements
Reduce energy consumption
No light switches
• 1:1 or 1:Many fixture control
• Limit of fixtures on one controller > dependant on total lighting load, voltage and total 0-10V current
• Occupancy control (PIR) > 20A relay > ON/OFF control > Adjustable time OFF delay
• Safety and energy savings
• Daylighting controls (photo sensor) > 0-10V dimming
• Optimize lighting and maximize energy savings
• Bi-level Lighting
• Safety and energy savings
• Fits common vapor tight fixtures by installing into ½” knock-out
• No need for additional conduit/j-boxes/wiring to implement lighting controls
• Deck Level Configuration
• Bluetooth enabled iOS smartphone devices (or iPod Touch)
• IP65 rated
•
Prevent water ingress in outdoor applications like parking garages
Note: This is a stand-alone system > it does not operate with other Douglas Lighting Controls Bluetooth devices (switches, sensors, controllers, gateways).
4
Company Confidential
Specifications
Functionality
Input Voltage
Occ. Sensor Range
Load Ratings
Dimming
Approvals
Warranty
Occupancy, CLC, Bi-level level light set point, time delay 10 min
Download Douglas Lighting Controls App from Apple App store for configuration
Outdoor Use – Rainproof when installed per instructions
For Installation with field-installed conductors of 60°C (140°F) minimum rating
See Installation Manual for complete details
120/277/347Vac 60Hz
Up to 40 feet
800W @ 120Vac standard ballast
1200W @ 277Vac standard ballast
3300W @ 277Vac electronic ballast
1500W @ 347Vac standard ballast
25mA current sinking
Certified to CAN/CSA Std. C22.2 No. 14
Conforms to UL508
Contains IC: 8254A-B1010SP0
Contains FCC ID: W7Z-B1010SP0
Standard 1-year
Part #: FMS-DLC001
20 ft.
30 ft.
40 ft.
5
Company Confidential
Douglas Lighting Controls Bluetooth® Fixture Controller & Sensor
Spacer
Spacer
Threaded chase nipple
break point for overhangs
less than ½” (12mm).
Fixture rail
Mounting
Use Spacer and full length threaded chase nipple for fixture rail
overhang greater than ½” (12mm).
Wiring
Red – relay/load
Black – hot/line
White - neutral
Grey
Violet
0-10V dimming
6
Company Confidential
Our Bluetooth® Wireless Mesh Architecture
7
Company Confidential
Douglas Lighting Controls Bluetooth® Controller
Converts fixtures into wirelessly controlled luminaires
•
•
•
•
•
Upgrade existing or add to new fixtures
Meet Energy Code requirements
Reduce Energy Consumption
Eliminates the need for control wires between fixtures
Makes design and installation easier
1:1 or 1:Many fixture control
• Limit of fixtures on one controller > dependant on total lighting load, voltage and total 010V current
Functionality
• Powered by Fixture
• 20A relay for ON/OFF control
• 0-10V dimming (Daylight Harvesting when Douglas Lighting Controls Bluetooth Sensor
added)
• Deck level commissioning using iOS smartphone App
• Communicates with other Douglas Lighting Controls Bluetooth enabled system devices
(occupancy sensors, gateways, and wall station switches)
• Easily installed using the ½” chase nipple and the included flying leads
o Red – Load Control
o White – Neutral
o Black – Hot
o Grey & Violet – 0-10V dimming
8
Company Confidential
Dimensions & Specs
Input Voltage
Output
Load Ratings
Dimming
Approvals
Environment
12VDC
output
for
BT-WOR-A
LED Status
Indicator
Factory
Reset
Warranty
120/277/347VAC 60Hz
12VDC, 30mA
800W @ 120Vac standard ballast
1200W @ 277Vac standard ballast
3300W @ 277Vac electronic ballast
1500W @ 347Vac standard ballast
100mA current sinking
Certified to CAN/CSA Std. C22.2 No. 14
Conforms to UL 508 Standard
FCC Class A
Class 2 Power Supply UL1310
Plenum Rated UL2043
ASHRAE 90.1 2010 Compliant
California Energy Commission Title 24 & NYLL48 Compliant
Contains IC: 8254A-B1010SP0
Contains FCC ID: W7Z-B1010SP0
Indoor, stationary, non-vibrating, non-corrosive atmosphere and
non-condensing humidity
Operating Temperature: 32°F to 104°F (0°C to 40°C)
Storage Temperature: 14° to 140°F (-25° to 60°C)
Standard 1-year
Part #: BT-PP20-A
9
Company Confidential
Installation
10
Company Confidential
Douglas Lighting Controls Bluetooth® Sensor
Occupancy and Daylight Sensing
• Meet Energy Code requirements
• Reduce Energy Consumption
Functionality
• Powered by Douglas Lighting Controls Bluetooth
Controller
• Occupancy Sensor for occupancy or vacancy control
• Daylight Sensor for Natural Daylight Harvesting
• Small form factor (1” lens diameter)
• LED indicator within lens
• Deck level configuration using iOS Smartphone App
• Innovative tool-less mounting
• One per Controller
Part #: BT-WOR-A
11
Company Confidential
Dimensions
Fits into a 15/16” hole
29/32”
11/4”
Part #: BT-WOR-A
12
Company Confidential
37/8”
Installation
Retention Flange
Fits into a 15/16” hole
#20AWG (20/2)
~50” length
Cutting head for quick
installation into soft
ceiling tiles
12VDC Output
Screwless Terminal Block
Douglas Lighting Controls
Bluetooth Controller
Part # BT-PP20-A
13
Company Confidential
Rubber Friction-Fit Ribs
14
Company Confidential
Douglas Lighting Controls Bluetooth® Switches
Wireless Control Switches
• To control fixtures using Douglas Lighting
Controls Bluetooth Controller
• 0-10V Dimmer & 1-button Switch
• 4-button Switch
• 8-button Switch
• Power by line voltage (120/277VAC & 347VAC
models)
• Field commission via Smartphone App
• Face plates sold separately
15
Company Confidential
Dimensions & Specifications
347VAC
Power
•
•
Line Voltage: 120/277VAC or 347VAC (device dependent)
Frequency: 60Hz
Operating Environment
• Indoor, stationary, non-vibrating, non-corrosive atmosphere and
non-condensing humidity
Operating Temperature
• 32°F to 104°F (0 to 40°C)
Storage Temperature
• -14°F to 140°F (-25° to 60°C)
120/277VAC
Approvals
• Certified to CAN/CSA Std. C22.2 No. 14
• Conforms to UL 508 Standard
• FCC Class A
• ASHRAE 90.1 2010 Compliant
• California Energy Commission Title 24 & NYLL 48 Compliant
Part #:
16
Company Confidential
120/277VAC
BT-DMSW-U-A
BT-4BTSW-U-A
BT-8BTSW-U-A
347VAC
BT-DMSW-3-A
BT-4BTSW-3-A
BT-8BTSW-#-A
Installation






For Installation with field-installed conductors of
60°C (140°F) minimum rating
Mounts directly into a standard listed single gang
wall station box
Install device into position
Connect wires as shown on diagram (14AWG)
Download free Smartphone Commissioning App
Use Commissioning App to configure system
17
Company Confidential
Douglas Lighting Controls Bluetooth® Dialog® Gateway
Sending and receiving Bluetooth commands into
the Dialog (WLC-3150) network
It is easily installed onto a wall or ceiling or
behind a wall or ceiling tile (not behind metal)
•
•
•
•
•
LED Status
Indicator &
Reset
Dialog 18/2 power and data network
Converts Bluetooth commands into Dialog protocol
Easily installed using mounting holes and screws
Dialog connector plug included
Plug ‘N Control®
Part #: BT-DLC-A
Dialog Network
Plug-in
18
Company Confidential
19
Company Confidential
Wireless Mesh Architecture
Sensor
Fixture Controller
Power to Sensor
Commissioning / User App
Switches
20
Company Confidential
Wireless Mesh Architecture to WLC-3150
Sensor
Fixture Controller
Gateway
Dialog
Central
Controller
Commissioning / User App
Switches
21
Company Confidential