Broadband Communications over Power Lines (BPL)

Download Report

Transcript Broadband Communications over Power Lines (BPL)

Broadband Communications
over Power Lines
(PLC)
By Marc C. Tarplee, Ph.D. N4UFP
ARRL Technical Coordinator
SC Section
What is PLC?
• PLC (also known as BPL) is a technique for
sending high speed data through the medium
voltage power distribution network
• The idea of sending data through the power
distribution network is not new
– Utilities use LF for network control and telemetry
(typically < 0.200 MHz)
– Schools have used carrier current system for “campus
radio” systems that operate in the AM band (0.530 –
1.700 MHz)
• What makes BPL different is that it uses
frequencies between 2 and 80 MHz
2. Types of PLC
• There are three major categories of PLC:
– Access PLC uses electrical distribution lines,
overhead or underground, to provide broadband
Internet access to homes and businesses.
• This is currently in the developmental stage
– In-building PLC uses the electrical wiring within a
building to network computers.
• Most systems use the HomePlug standard which provides
protection for amateur frequencies
– Control PLC operates below 500 kHz, and is used
by electric-utility companies to control their
equipment using the power-lines as transmission
lines.
• These systems are not a problem, although it is interesting to
note that utilities successfully lobbied against an amateur VLF
allocation, claiming that amateur transmissions could disrupt
their communications.
3. PLC Modulation Techniques
Access PLC
• Access PLC systems are presently under
development. Current systems use OFDM
(orthogonal frequency division multiplexing) in
combination with some type of PSK .
• Carrier frequencies can be between 2 and 30
MHz.
• No filtering provisions are made to protect other
users of the HF/VHF spectrum
• Data throughput > 10 Mb/sec
HomePlug
• HomePlug uses a combination of OFDM
(orthogonal frequency division multiplexing) and
DQPSK (differential quadrature phase shift
keying) to send data through power lines within
the home.
• Carrier frequencies are between 4.5 and 21 MHz.
• The modem output has notches at 3.5, 7.0, 10.1,
14.0, and 18.1 MHz to reduce interference to
amateurs.
• Data throughput > 10 Mb/sec
HomePlug
• Software in the receiver continuously determines
the transfer function of the medium and carrier
frequencies are changed to use the best available
spectrum.
• HomePlug signal power is spread over the entire
4.5 – 21 MHz bandwidth as the carrier frequencies
are changed.
• HomePlug signals can pass through a residential
service entry panel with less than 10 dB loss.
HomePlug Spectral Mask
Control/Carrier Current PLC
• These use frequencies below 1.7 MHz.
– Carrier current AM signals 0.53 – 1.70 MHz
– LF telemetry/control signals used by utilities <0.2 MHz
• Signals have narrow bandwidth ( < 10 KHz) and
have carrier frequencies below all amateur bands.
• These signals do not generally present serious
interference problems to amateurs
• Data throughput << 1 Mb/sec
4. RFI from Access Line PLC
• Tests involving PLC systems in Japan and Europe
indicate that PLC can cause significant
interference to other users of the HF spectrum.
• Medium voltage power distribution lines look very
much like antennas at HF wavelengths.
• The next slide shows the far-field pattern of a 328
ft (100 m) segment of a typical MV distibution
line. The conductors are at a height of 10m (32 ft
10 in) and they are spaced 1.5 m (4ft 5in) apart.
The load is assumed to be the primary of a
neighborhood transformer, which is assumed to
have an impedance of 10 – j25 ohms.
Elevation patterns for radiation from MV Power Lines
Perpendicular to Lines
Parallel to Lines
28 MHz
14 MHz
7 MHz
3.5 MHz
0.15 MHz
+5 dBi
28 MHz
14 MHz
7 MHz
3.5 MHz
0.15 MHz
+9 dBi
• As might be expected, the power lines look like long
wire antennas at HF, with some gain and a complex
multi-lobed radiation pattern
• It is interesting to note that the signal transmitted from
the power lines in the LF range (150 kHz) is less than –
70 dbi in any direction.
• Utilities’ RFI experience in the LF range is no predictor
of RFI problems in the HF range.
• Because overhead power lines run in all directions, the
resultant field produced by the entire power
distribution system should be more or less isotropic in
the azimuthal plane.
• ARRL simulations indicate that a fully-deployed access
line PLC system would raise the noise floor by 70 dB
(9 s-units + 16 dB)
Japanese PLC RFI Study
Noise Floor
• These measurements were made at 7 MHz on a 96
km long path in Japan.
• PLC signals raised the noise field strength by 25
dB
Effect of PLC on HF Coverage
> 75%
~ 50%
< 25%
20 m Coverage under
normal conditions
20 m Coverage with access
PLC in neighborhood
ARRL PLC Video
5. RFI from HomePlug PLC
• HomePlug uses a spectral mask that provides 30
dB of filtering in the amateur HF bands.
• At current RF brightness levels of –80 dBm/Hz,
HomePlug signals can cause interference to
antennas (especially indoor) that run within 2 – 3
m of household power lines.
• HomePlug signals can also leak into other
households with < 10 dB of attenuation, causing
problems for all homeowners sharing a common
transformer.
6. What Can Be Done?
• The FCC recently closed off comment on the PLC
docket. Hundreds of amateurs did comment on the
problems with PLC during the comment period.
• Measurements need to be made. If a utility is
deploying PLC in your area, please make
measurements of the noise. We need to show the
FCC what the problems are.
• It is very likely that some form of PLC will be
implemented – the economic potential is to great.
It is important for amateurs to help steer the
implementation so that our frequencies are
protected