Chapter3 : Oscilloscope Measurement Techniques

Download Report

Transcript Chapter3 : Oscilloscope Measurement Techniques

CENG3480_B2
Measurement Techniques
Reference: Chapter 3 Measurement Techniques of
High speed digital design , by Johnson and Graham
High-speed logic: Measurement
(v.9a)
1
Revision: frequency domain processing
and filtering




(1) Low-pass filter
(2) High-pass filter
(3) Band pass filter
(4) Tuned filter (narrow band pass filter)
 See http://www.ee.duke.edu/~cec/final/node1.html
High-speed logic: Measurement (v.9a)
2
Revision: Filtering is in Frequency domain not
time domain
 Filtering is in Frequency domain, don’t mix up with high/low
amplitude levels
Higher amplitude
lower freq.
Lower amplitude
Higher freq.
amplitude
time
High-speed logic: Measurement (v.9a)
3
Examples of filters

0dB
gain
Freq.
R
C
L
R
0dB
R
C
L
Freq.
R
High-speed logic: Measurement (v.9a)
4
Analogies of Low-pass and High pass filters

High pass
Low pass
High-speed logic: Measurement (v.9a)
5
A common example of a low pass filter: An operational
amplifier:
Diagram of gain bandwidth product, from [1]
High-speed logic: Measurement (v.9a)
6
(1) Low pass filter (Frequency low than F-3dB can pass, or has
power gain more than 0.5)
 (1) Low pass (e.g. op.amp)


At low freq, Gain=1=0dB
At -3dB cut off, gain = 0.5, = -3dB
E.g.
Ic(t)
R
C Vc
Vin
analog
system
Vout
Gain in dB = 20 log10(Vout/Vin)
3dB cut off point
0
-3dB
Frequency
B=Bandwidth
High-speed logic: Measurement (v.9a)
Flowpass(-3dB) =1/2RC
7
(2) High pass filtering, (Frequency higher than F-3dB can pass, or
has power gain more than 0.5)
 High pass


At low freq, Gain=0= -dB
At -3dB cut off, gain =0.5, = -3dB
R
L
Vin
analog
system
Vout
Gain in dB = 20 log10(Vout/Vin)
3dB cut off point
0
-3dB
Frequency
F-highpass(-3dB) = 1/2(L/R)
High-speed logic: Measurement (v.9a)
8
(3) Band - Pass Filters (Frequency within a range can pass)
E.g. A band-pass filter by combining a
low pass F low-pass(-3dB) filter ,
an ideal amplifier and
a high pass F high-pass(-3dB) filter.
R
Ideal amplifier
L
gain
0dB
3dB
Band width
High-speed logic: Measurement (v.9a)
9
(4) Tuned filter: special case of a band-pass filter -- only a
narrow band can pass
 When the low pass F low-pass(-3dB), and the a high pass
F high-pass(-3dB)filter are close.

Fc=center frequency,

F=bandwidth (narrow)
R
C
L
gain
0dB
3dB
Fc =1/[2(LC)
1/2 ]
Frequency
Band width F
High-speed logic: Measurement (v.9a)
10
Rise time and bandwidth of CRO probes
 All scientific instruments have limitations
 Limitations of oscilloscope systems

inadequate sensitivity
• Usually no problem because except most sensitive digital network, we are
well above the minimum sensitivity (analogue system is more sensitive)

insufficient range of input voltage?
• No problem. Usually within range

limited bandwidth?
• some problems because all veridical amplifier and probe have a limited
bandwidth
 Two probes having different bandwidth will show different
response.
Using faster probe
Using slower probe (6 MHz)
High-speed logic: Measurement (v.9a)
11
Oscilloscope probes
 Components of oscilloscope systems



Input signal
Probe
Vertical amplifier
 We assume a razor thin rising edge. Both probe and vertical
amplifier degrade the rise time of the input signals.
High-speed logic: Measurement (v.9a)
12
 Combined effects: approximation


Serial delay
The frequency response of a probe, being a combination of several random
filter poles near each other in frequency, is Gaussian.
1
2 2
Trise_ composite  (T1  T2      TN )
2
2
 Rise time is 10-90% rise time

When figuring a composite rise time, the squares of 10-90% rise times add
 Manufacturer usually quotes 3-db bandwidth F3db

approximations T10-90= 0.338/F3dB for each stage (obtained by simulation)
High-speed logic: Measurement (v.9a)
13
Example:
Given: Bandwidth of probe and scope = 300 MHz
Tr signal = 2.0ns
Tr scope = 0.338/300 MHz = 1.1 ns
Tr probe = 0.338/300 MHz = 1.1 ns
Tdisplayed = (1.12 + 1.12 +2.02)1/2
= 2.5 ns
For the same system, if Tdisplayed = 2.2 ns, what is the actual rise time?
Tactual = (2.22 - 1.12 – 1.12)1/2
= 1.6 ns
High-speed logic: Measurement (v.9a)
14
Self-inductance of a probe ground loop




A Primary factor degrading the performance
Current into the probe must traverse the ground loop on the way back to source
The equivalent circuit of the probe is a RC circuit
The self-inductance of the ground loop, represented on our schematic by series
inductance L1, impedes these current.
High-speed logic: Measurement (v.9a)
15
 Typically, 3 inches (of 0.02” Gauge wire loop) wire on
ground plane equals to (approx) 200 nH
 Input C = 10pf
 TLC = (LC)1/2 = 1.4ns
 T10-90 = 3.4 TLC = 4.8ns
 This will slow down the response a lot.
High-speed logic: Measurement (v.9a)
16
Estimation of circuit Q
 Output resistance of source combine with the loop inductance & input
capacitance is a ringing circuit.
 Where
( L / C )1/ 2
Q
Rs
 Q is the ratio of energy stored in the loop to energy lost per radian during
resonant decay.
 Fast digital signals will exhibit overshoots. We need the right Rs to damp the
circuit. On the other hand, it slows down the response.
High-speed logic: Measurement (v.9a)
17
 Impact: probe having ground wires, when using to view very fast signals
from low-impedance source, will display artificial ringing and overshoot.
 A 3” ground wire used with a 10 pf probe induces a 2.8 ns 10-90% rise
time. In addition, the response will ring when driven from a lowimpedance source.
High-speed logic: Measurement (v.9a)
18
Remedy
 Try to minimize the earth loop wire

Grounding the probe close to the signal source
High-speed logic: Measurement (v.9a)
Back to page 29
19
Spurious signal pickup from probe ground loops
 Mutual inductance between Signal
loop A and Loop B
LM  5.08
A1 A2
r3
where




A1 (A2) = areas of loops
r = separation of loops
Refer to figure for values.
In this example, LM = 0.17nH
 Typically IC outputs

max dl/dt = 7.0 * 107 A/s
Vnoise  LM
dI
 (0.17nh)(7.0 107 V / s )  12mV
dt
 12mV is not a lot until you have a 32-bit bus; must try to minimize loop area
High-speed logic: Measurement (v.9a)
20
A Magnetic field detector
 Make a magnetic field detector to test for noise
High-speed logic: Measurement (v.9a)
21
How probes load down a circuit
 Common experience

Circuit works when probe is inserted. It fails when probe is removed.
 Effect is due to loading effect, impendence of the circuit has
changed. The frequency response of the circuit will change as
a result.
 To minimize the effect, the probe should have no more than
10% effect on the circuit under test.

E.g. the probe impedance must be 10 times higher than the source
impedance of the circuit under test.
High-speed logic: Measurement (v.9a)
22
An experiment showing the probe loading effect
A 10 pf probe loading a 25 ohm circuit
 A 10 pf probe looks like 100 ohms to a 3 ns rising edge
 Less probe capacitance means less circuit loading and better measurements.
High-speed logic: Measurement (v.9a)
23
Special probing fixtures
 Typical probes with 10 pf inputs and one 3” to 6” ground
wire are not good enough for anything with faster than 2ns
rising edges
 Three possible techniques to attack this problem



Shop built 21:1 probe
Fixtures for a low-inductance ground loop
Embedded Fixtures for probing
High-speed logic: Measurement (v.9a)
24
Shop-built 21:1 probe
 Make from ordinary 50 ohm coaxial cable
 Soldered to both the signal (source) and local ground
 Terminates at the scope into a 50-ohm BNC connector
 Total impedance = 1K + 50 ohms;
if the scope is set to 50 mv/divison,
the measured value is = 50 * (1050/50) = 1.05 V/division
High-speed logic: Measurement (v.9a)
25
Advantages of the 21:1 probe
 High input impedance = 1050 ohm
 Shunt capacitance of a 0.25 W 1K resistor is around 0.5 pf,
that is small enough.

But when the frequency is really high, this shunt capacitance may
create extra loading to the signal source.
 Very fast rise time, the signal source is equivalent to
connecting to a 1K load, the L/R rise time degradation is
much smaller than connecting the signal to a standard 10 pf
probe.
High-speed logic: Measurement (v.9a)
26
Fixtures for a low-inductance ground loop
 Refer to figure on page 19
 Tektronix manufactures a probe fixture specially designed to
connect a probe tip to a circuit under test.
High-speed logic: Measurement (v.9a)
27
Embedded Fixture for Probing
 Removable probes disturb a
circuit under test. Why not
having a permanent probe
fixture?
 The example is a very
similar to the 21:1 probe. It
has a very low parasitic
capacitance of the order 1
pf, much better than the 10
pf probe.

Use the jumper to select
external probe or internal
terminator.
High-speed logic: Measurement (v.9a)
28
Avoiding pickup from probe shield currents
 Shield is also part of a current path.
 Voltage difference exists between logic ground and scope
chassis; current will flow.
 This “shield current * shield resistance R shield“ will produce
noise Vshield
High-speed logic: Measurement (v.9a)
29
 VShield is proportional to shield resistance, not to shield
inductance because the shield and the centre conductor are
magnetically coupled. Inductive voltage appear on both
signal and shield wires.
 To observe VShield




Connect your scope tip and ground together
Move the probe near a working circuit without touching anything. At
this point you see only the magnetic pickup from your probe sense
loop
Cover the end of the probe with Al foil, shorting the tip directly to the
probe’s metallic ground shield. This reduces the magnetic pickup to
near zero.
Now touch the shorted probe to the logic ground. You should see only
the VShield
High-speed logic: Measurement (v.9a)
30
Solving VShield problem
 Lower shield resistance (not possible with standard probes)
 Add a shunt impedance between the scope and logic ground.

Not always possible because of difficulties in finding a good
grounding point
 Turn off unused part during observation to reduce voltage
difference

Not easy
 Use a big inductance (magnetic core) in series with the shield


Good for high frequency noise.
But your inductor may deteriorate at very high frequency.
 Redesign board to reduced radiated field.

Use more layers
 Disconnect the scope safety ground

Not safe
High-speed logic: Measurement (v.9a)
31
 Use a 1:1 probe to avoid the 10 time magnification when
using 10X probe
 Use a differential probe arrangement
High-speed logic: Measurement (v.9a)
32
Viewing a serial data transmission system
 Jitter observed due to intersymbol interference and additive
noise.
 To study signal, probe point D and use this as trigger as well.
High-speed logic: Measurement (v.9a)
33
 No jitter at trigger point due to repeated syn with positivegoing edge.

This could be misleading
 For proper measurement, trigger with the source clock


The jitter is around half of the previous one.
If source clock is not available, trigger on the source data signal point
A or B (where is minimal jitter)
High-speed logic: Measurement (v.9a)
34
Slowing Down the System clock
 Not easy to observe high speed digital signals which include
ringing, crosstalk and other noises.
 Trigger on a slower clock (divide the system clock) allows
better observations because it allows all signals to decay
before starting the next cycle.
 It will help debugging timing problems.
High-speed logic: Measurement (v.9a)
35
Observing crosstalk
 Crosstalk will



Reduce logic margins due to ringing
Affect marginal compliance with setup and hold requirements
Reduce the number of lines that can be packed together
 Use a 21:1 probe to check crosstalk



Connect probe and turn off machine; measure and make sure there is
minimal environment noise.
Select external trigger using the suspected noise source
Then turn on machine to observe the signal which is a combination of
primary signal, ringing due to primary signal, crosstalk and the noise
present in our measurement system
High-speed logic: Measurement (v.9a)
36
High-speed logic: Measurement (v.9a)
37
 Try one of the followings to observe the cross talk

Turn off primary signal (or short the bus drivers)
• Varying the possible noise source signal (e.g. signal patterns for the bus)

Compare signals when noise source is on and off
• Talk photos with the suspected noise source ON and source OFF.
• The difference is the crosstalk

Generating artificial crosstalk
• Turn off, disabled, short the driving end of the primary signal. Induce a
step edge of know rise time on the interfering trace and measure the
induced voltage.
• Useful technique when measuring empty board without components.
High-speed logic: Measurement (v.9a)
38
Measuring Operating Margins
 In digital system measurements, we are interested to stress the system to
ensure the system is within operation margin specified.
 Make sure the arrangement is automatic and self recovery
 Some of the common tests

Additive noise
•
•
•
•

Add random noise to every node
Sine waves, square waves or random pattern
Difficult to administer
Suitable for data receivers and transmitters
Adjusting the timing of a large bus (clock skew margin test)
• Test the combine effects of system setup time, hold time and operating margin etc.
• Connect the devices’ clock signals using the following methods.
– Clock adjustment by coax delay (vary the length)
– Clock adjustment by pulse generator (variable delays)
– Simple circuits for clock phase adjustment
– Clock adjustment by a phase-locked loop
– Clock adjustment by voltage variation
High-speed logic: Measurement (v.9a)
39

Power Supply
• Power supply variation can change response characteristics
• Vary the supply over a + 10% range

Temperature
• Temperature will vary the delay characteristics
• Can use cooling spray, blow dryer etc. Some companies use temperature
control ovens
• Make sure the temperature probe is attached to the right place

Data Throughput
• Compose a suite of operations that exercise each individual connections
• Not easy to compose test pattern that represents the real situations. Often
system passes tests but fails at real operations.
• Good data pattern will uncover unexpected avenues of noise coupling
which causes failures
• Complex tests are expensive
High-speed logic: Measurement (v.9a)
40