Transcript Slide 1

50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
11/2010
©Copyright 2010 Desco Industries Inc.
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
Description
The EMIT Dual-Wire Dual-Operator
Programmable Monitor can maintain two
work surfaces and two operators at ground potential to
virtually eliminate the risk of ESD damage. The highly visible LED display and
audible alarm makes it easy to monitor the status of the work surfaces and
operators. The Dual-Wire Dual-Operator Programmable Monitor uses EMIT’s
patented dual resistive loop technology. No other method is as direct and
reliable. Both work surfaces, and individual operator resistance limits, can be
programmed and reconfigured as required. If the ground potential of either
work surface or operator is lost the, monitor immediately alarms (both audible
and visual). The monitor is unaffected by capacitance variations associated
with personnel and environmental conditions.
Vermason.co.uk
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
Benefits
Continuous monitors pay for themselves, by improving quality, productivity, and
eliminating daily wrist strap testing and test result logging. Per ESD-S1.1
paragraph 6.1.3 Frequency of Functional Testing, “The wrist strap system
should be tested daily to ensure proper electrical value. Daily testing may be
omitted if constant monitoring is used.”.
Vermason.co.uk
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
• Dual Wire Continuous Monitors provide
redundancy; even if one dual wire
wrist strap conductor is severed,
operator has reliable path-to-ground with the other wire
• Patented Resistance Loop Monitoring Technology
• Monitoring of two operators and two ground connections independently
• For use with dual-wire wrist straps
• Adjustable alarm level
• Independent alarming conditions: audible and visual
• Resistance, programmable, no manual adjustment necessary
• Visual display for all status
• Made in America
Vermason.co.uk
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
Operation
Wrist Strap Connections
Once all the connections have been
made and the unit has been powered up, the unit is ready
for operation. Install operator wrist straps and ground wires. Dual snaps on the
operator ground wires attach to the wristband snaps and the mono plug on the
other end inserts into the operator remote. The operator's monitoring is in
"STANDBY" mode until the operator's ground wire is plugged into the remote jack
for that station.
NOTE: The operator remote has two jacks. One is a 3.5 mm mono jack for use with a dual wrist strap. A
dual operator ground wire plugged into this jack will be monitored. The other jack is a grounded banana
jack for use with a single conductor operator ground wire. This is a grounded guest hook-up that is
not monitored.
Vermason.co.uk
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
Specifications
•
•
•
•
•
•
Two user selectable resistance levels of 10 Meg ohms or 35 Meg ohms.
Two user selectable test voltage settings of +5V or +8V.
SCCN compatible data output.
Stainless Steel housing.
Size: 11cm W x 11cm D x 4.6cm H
Plug-in power supply: 110 VAC/60Hz input, 12VDC/500mA output or 230VAC/50Hz
input, 12VDC/500mA output. 2.5mm connector - center positive. Any alternate
transformer must comply with the Safety Extra Low Voltage (SELV) insulation
requirements.
• Important: This appliance has a metal casing but the earth connection is only used for
operational purposes. It is considered to be class I and tested as class II. The power
supply connection plug is accessible to the user and there is no safety insulation
inside the monitor. Therefore, the insulation of the power supply is critical.
• Rated Power consumption: 3.6VA
Vermason.co.uk
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
Accessories
•
•
•
•
•
50524 Limit Comparator
50525 Replacement Black Remote
50526 Replacement White Remote
50527 Power Supply, UK /Asia, 3 pin
50540 Power Supply, Europe, 2 pin
Vermason.co.uk
50515
Dual-Wire Dual-Operator
Programmable Continuous Monitor
ESD Handbook TR20.20 paragraph 5.3.2.4.4
“Typical test programs recommend that wrist straps that are used daily should be
tested daily. However, if the products that are being produced are of such value
that knowledge of a continuous, reliable ground is needed, and then continuous
monitoring should be considered or even required.”
Vermason.co.uk