No Slide Title
Download
Report
Transcript No Slide Title
ACS800 regenerative
drives
Product presentation
Insert image
here
© Copyright year ABB.
All rights reserved. - 1 7/21/2015
Insert image
here
ACS800 regenerative drives
Table of content:
1. What is a regenerative drive
2. ACS800-11 product series
3. ACS800-17 product series
4. ACS800 advantages
5. Regenerative drive features
© Copyright year ABB - 2 -
6. Typical applications
What is a VSD
Uline
UDC
Rectifier
Uout
Filter
L
DC link
+
Inverter
L1
Supply L2
C
Ud
L3
-
© Copyright year ABB - 3 -
Monitoring
Control
Control Electronics
control, monitoring and communication
Motor
U1
V1
W1
M3~
What is a regenerative VSD
Uline
Filter
UDC
Inverter
Uout
DC link
+
Inverter
L1
Supply L2
C
Ud
L3
-
© Copyright year ABB - 4 -
Monitoring
Control
Control Electronics
control, monitoring and communication
Motor
U1
V1
W1
M3~
Why regenerative drive?
Applications with cyclic
or continuous braking
© Copyright year ABB - 5 -
Braking energy returned
to network - not wasted
No additional resistor
for energy dissipation
Space saving
No need for handling
the waste heat
kW
300
Power
200
+
100
1
-100
-200
-300
2
3
4
-
5
Time
ACS800 product series
single drive
Motors
6-pulse
Supply Unit
M
12-pulse
Supply Unit
(Medium Voltage)
Software:
Braking
Chopper
Regenerative
Supply Unit
3 AC
multidrive
Supply Section
© Copyright year ABB - 6 -
6-pulse
Supply Unit
12-pulse
Supply Unit
Drive Sections
Output
Filters
- dU/dt
- sine
• Standard
• System Application
• Master-Follower
• Crane Control
• Extruder Control
• Pump & Fan Control
• Centrifuge Control
• Spinning Control &
Traverse Control
M
M
M
Regenerative
Supply Unit
© Copyright year ABB - 7 -
Product offering
Wall-mounted regenerative
drive ACS800-11
Cabinet-built regenerative
drive ACS800-17
BACK TO
CONTENT
ACS800 regenerative drives
Table of content:
1. What is a regenerative drive
2. ACS800-11 product series
3. ACS800-17 product series
4. ACS800 advantages
5. Regenerative drive features
© Copyright year ABB - 8 -
6. Typical applications
ACS800 single drive
ACS800-11 regenerative drive
Everything inside
Regenerative drive in one
package
Line filter and charging included
Compact and complete
Versatile product markings
© Copyright year ABB - 9 -
CE, UL, CSA, C-Tick …
ACS800 series
Premium technology
Common platform
Global support
7.5 - 110 kW
ACS800 single drive
ACS800-11 regenerative drive
© Copyright year ABB - 10 -
Three voltage classes
230 Vac
400 Vac
500 Vac
Enclosure class IP21
Built-in options
EMC filter for 1st or 2nd
environment
Analog and digital I/O extension
Fieldbus modules
Pulse encoder interface
7.5 - 110 kW
Built-in I/O options
Plug-in type option modules fast and easy
© Copyright year ABB - 11 -
3 option modules
Analogue and digital I/O
extensions
Fieldbuses
Pulse encoder interface
PC and Master-Follower
connection (DDCS)
Everything inside the drive
Factory installed or easily
extendable
ACS800 single drive
ACS800-11 regenerative drive
© Copyright year ABB - 12 -
Compact and complete
Regenerative drive in one
package
Factory tested package
No wiring and cabling mistakes
on installation site
High packing density, small size
Narrow design, low installation
space requirement
7.5 - 110 kW
Everything inside
Complete factory tested package results to…
One compact…
instead of this!
EMC filter
Charging
Choke
Capacitor
Choke
© Copyright year ABB - 13 -
Frequency
Converter
Frequency
Converter
BACK TO
CONTENT
ACS800 regenerative drives
Table of content:
1. What is a regenerative drive
2. ACS800-11 product series
3. ACS800-17 product series
4. ACS800 advantages
5. Regenerative drive features
© Copyright year ABB - 14 -
6. Typical applications
ACS800 single drive
ACS800-17 regenerative drive
Full regenerative drive in cabinetbuilt range
High performance drive for
demanding applications
Small size, high output
Versatile product markings
© Copyright year ABB - 15 -
CE, UL, CSA, C-Tick …
Common ACS800 technology
World-wide support
Common user interface
55 - 2500 kW
ACS800 single drive
ACS800-17 regenerative drive
Enclosure class
Voltage classes
© Copyright year ABB - 16 -
IP21, IP22, IP42, IP54, IP54R
400V, 500V and 690V
Customized solutions
Wide variety of different standardised
configurations
Custom design by application
engineering
55 - 2500 kW
© Copyright year ABB - 17 -
ACS800-17 product series
Frame size R6 55-90 kW
Frame size R7i 110-132 kW
Frame size R8i 160-400 kW
Ratings at 400Vac
ACS800-17 product series
© Copyright year ABB - 18 -
Frame sizes 2-6xR8i up to 2500 kW
Product construction
Main contactor
Line side LCL filter
Load switch
Line supply unit
© Copyright year ABB - 19 -
Control and
auxiliaries
Free space for
terminals behind
swing-frame
BACK TO
CONTENT
Motor inverter
ACS800 regenerative drives
Table of content:
1. What is a regenerative drive
2. ACS800-11 product series
3. ACS800-17 product series
4. ACS800 advantages
5. Regenerative drive features
© Copyright year ABB - 20 -
6. Typical applications
Safe solutions with ABB
Complete solutions from ABB
Extensive product portfolio
© Copyright year ABB - 21 -
Drives
Motors
Transformers
Automation
Relays
Instrumentation
etc…
Global service network
Safe solutions with ABB
© Copyright year ABB - 22 -
World wide
presence and
support
On every continent,
in virtually every
country
In pre- and after
sales support
Time saving commissioning
© Copyright year ABB - 23 -
Start-up assistant
Fast and easy
commissioning procedure
Intelligent, interactive
start-up guide
Plug and play line control
Multilingual
On-line information
system
© Copyright year ABB - 24 -
Flexibility - programmability inside
Minimized Investment due to SW Features
Cost Saving - Built-in Compatibility
Solutions for Various Needs
© Copyright year ABB - 25 -
Redundancy in high power units
Built-in redundancy through
parallel connected modules in
high power range
Each module is a complete
three-phase inverter
Enables redundancy
Unique in drives - not
available in previous
generation ABB drives or in
existing competitors’ drives
Quick serviceability
BACK TO
CONTENT
ACS800 regenerative drives
Table of content:
1. What is a regenerative drive
2. ACS800-11 product series
3. ACS800-17 product series
4. ACS800 advantages
5. Regenerative drive features
© Copyright year ABB - 32 -
6. Typical applications
ACS800-11 and common DC
© Copyright year ABB - 33 -
Common DC system
DC link available in terminals for
common DC configurations
Simple way to implement low
power common DC system
Comparison to thyristor bridge
Motoring
bridge
© Copyright year ABB - 34 -
If thyristor bridge is regenerating
and line voltage drops, a
thyristor cannot interrupt the
current. The current can rush
and blow the fuses. This is also
risk for components.
IGBT is able to switch off the
current and protect the
components. Control can
function even during voltage dip.
AC
Regenerating
bridge
DC +
DC -
DC +
AC
DC -
Introduction to DTC control
Excellent motor control in all situations
Torque step rise time
DTC
< 5 msec.
Flux vector
10 to 20 msec.
Open loop PWM
> 100 msec.
Accurate speed or torque
control
1,00
New Current level
Current
0,50
Time
0,00
Torque
DTC
Full torque at zero speed
Power loss ride through
© Copyright year ABB - 35 -
No unnecessary process
interruptions
DTC principle utilised also on
line converter control
PWM
New Torque
level
DTC and line side converter
Ultra-fast transition between
motoring and generating
Line converter is capable of
keeping the DC voltage steady
© Copyright year ABB - 36 -
Motoring and generating
performance is equal
Linear and smooth
transitions are possible
From 130 % motoring to 110 % generating
200
% of nominal torque
150
100
50
Time (ms)
0
-50
-100
-150
Immunity to supply voltage
variations and disturbances
Good power factor and harmonic performance -> economical
transformer dimensioning
Voltage stabilisation
Line converter control follows
DC voltage reference
ACS800-17 and line voltage 400V
U1=400V
Udc=560V
In low network voltage
conditions motor still gets full
voltage
U2=400V
M
ACS800-17 and line voltage 400V -10%
This is advantage in motor
dimensioning
U1=360V
Udc=560V
U2=400V
M
ACS800-17 and line voltage 400V +10%
© Copyright year ABB - 37 -
U1=440V
Udc=620V
U2=440V
M
Voltage boosting
© Copyright year ABB - 38 -
It is possible to set DC voltage
reference to higher value
… and use 500 Vac class
equipment in 400 Vac network
Optimisation possibility
depending on the load curve
Constant flux range can be
extended
BACK TO
CONTENT
ACS800-17 with default reference
U1=400V
Udc=540V
U2=400V
M
ACS800-17 with increased reference
U1=400V
Udc=710V
U2=500V
M
ACS800 regenerative drives
Table of content:
1. What is a regenerative drive
2. ACS800-11 product series
3. ACS800-17 product series
4. ACS800 advantages
5. Regenerative drive features
© Copyright year ABB - 39 -
6. Typical applications
© Copyright year ABB - 40 -
Typical applications
Centrifuge and decanter
Crane
Downhill conveyors
Elevator
Escalator
Machine tool
Metal sheet press
Ski-lift
Storage
Test bench
Winch
Windmills
Example: metal sheet press
DC technology was historic
standard in presses
There is trend to AC
technology
© Copyright year ABB - 41 -
Less maintenance of the
motor
Network performance (power
factor, harmonics)
Better controllability
Good dynamic performance of
DTC is a benefit
Load impact during stroke
causes heavy speed drop
Example: sugar centrifuge
© Copyright year ABB - 42 -
Regenerative AC drive
benefits:
Power line by sugar
production areas is often not
very strong
Improved quality due to good
controllability
Harvest season short and
intensive
Reliability
Availability
After sales support
© Copyright year ABB - 43 -
Example: test bench
Good control dynamics and
response times required
Continuous braking
ACS800-17 benefits:
Fast DTC control follows
well even heavy testing
DTC has good repeatability
Robust IGBT supply unit
Fast control interface
developed
© Copyright year ABB - 44 -
Example: escalators
Braking capability needed
especially in long belt
installations
Standardization of
electrification
© Copyright year ABB - 45 -
Example: crane
Dynamic, reliable control
Energy savings through
regenerative braking
Less maintenance with AC
technology
Robust against network
disturbances
© Copyright year ABB - 46 -
Example: ski lift
Absolute safety and
availability required
Power line often weak at
mountains
Regenerative braking when
load coming downward
ACS800-17 benefits:
High reliability
Excellent network
performance
Smooth controllability
High efficiency of AC motor
BACK TO
CONTENT