BE1-GPS Product Screenshow

Download Report

Transcript BE1-GPS Product Screenshow

BE1-GPS100
Generator
Protection System
BE1-GPS100
What is it?
Generator Protection System based on
the successful 851/951 platform
• Includes Multifunction Protection and:
– Metering and Control
– Relay Status Alarms
– Breaker Monitoring
– Detailed Event and Oscillography Data
– Communication (Status, Metering, Control,
Settings, Events)
– Programmable Logic
– Programmable I/O
BE1-GPS100
What makes it unique?
• High Flexibility
– Flexibility in protection settings
– Flexibility in application logic
– Flexibility in packaging (H1 and S1 case)
• Optimal functionality in a small package
Typical BE1-GPS One Line
52
VX on Broken Delta, 3Vo, gen neutral
24
x81
O/U
47
x27N
x59N
x27P
x59P
Bus
VX*
3,2
25
* VX: one
optional phase
voltage input
usable for either
gen neutral or
sync check
G
46Q
50TN
50TP
BF
51N
51P
x40Q
x32
151N
VR/VC
60FL
3
x50/51N: 3Io or Ig
VX, Ig Optional
IE
Logic
x62
27-3N
1 neu
VX*
R or X
+ Front Display, RS232 ASCII, RS485, ASCII/Modbus/DNP, Oscillography,
SOE, 2 Setting Groups, Programmable Logic, 4 status in, 6 contact out
BE1-GPS100
Protection - Current
• 51V: Phase Overcurrent
– Settable for:
* Voltage Controlled (51/27C)
* Voltage Restrained (51/27R)
* Normal (51)
– Multiple time curves using IEEE C37.112-1996:
* 7-CO, 5-IAC, 4-IEC, 1-fixed, 1-programmable
* Each with instantaneous or integrating reset
• 51N, 151N
– Each can be assigned to:
* Three Phase Residual-3I0 (IN)
* Optional Independent Ground Input (IG)
BE1-GPS100
Protection - Current
• 46: Negative Sequence Overcurrent
– Accepts K factor based I2 curve or
– Standard time overcurrent curves
• BF: Breaker Failure
– Timer with fast dropout current detector
– Supervise / Block with either internal
elements or external inputs
– Start / Initiate with either internal elements
or external inputs
BE1-GPS100
Protection - Current
• 50TP: Phase Instantaneous / Def. Time
–
–
–
–
Use for Inadvertent Energization logic or
On line indication or
Phase fault protection or
User-defined purpose
• 50TN: Ground Inst. / Def. Time
– Use for Inadvertent Energization logic or
– Ground fault protection or
– User-defined purpose
BE1-GPS100
Protection - Current
• 51N monitoring Optional Independent
Ground Input can act as OC differential.
• For those applications requiring
Generator Differential (87):
Use the BE1-87G or the BE1-CDS220
– Redundancy gained by placing the
differential in a separate package avoids
the “all your eggs in one basket” pitfall
• Basler offers competitive pricing for the
CDS220/GPS100 combo package
BE1-GPS100
Protection - Voltage
• 24: Volts/Hertz
– Inverse quantity squared curve
* Time delay proportionate to (1/(M-1)^2)
• 25: Sync Check
– dV, dF, df
– Sync allowed on gen. frequency>bus
frequency if desired
– Instantaneous response; no time delay
needed, but can be added with 62 timer
BE1-GPS100
Protection - Voltage
• 27P, 127P: Phase Undervoltage
• 59P, 159P: Phase Overvoltage
– Unique user selected 1/3, 2/3, or 3/3 logic
– Definite time
• 47: Negative Sequence Voltage
– Reverse phase energization detection
– Applicable for mobile generators
– Definite time
BE1-GPS100
Protection - Voltage
• 27X, 127X, 59X, 159X : Auxiliary Over and
Under Voltage
– Definite Time
– 3 User Selected Modes
- Mode 1: Aux VT, fundamental frequency
* Monitor bus or monitor generator neutral for ground fault
- Mode 2: Phase VT, 3Vo
* Monitor generator high side for ground fault
- Mode 3: Aux VT, 3rd Harmonic
* Absence of neutral 3rd harmonic indicates
ground fault
BE1-GPS100
Protection - Voltage
• 60FL: Fuse Loss Detection Algorithm
– Negative Sequence Voltage in the absence
of negative sequence current
– Loss of all phase voltages with no phase
current, with breaker closed
• 81, 181, 281, 381: Over / Under Frequency
– Definite time
– Frequency set points can be Over or Under
– Undervoltage blocking
BE1-GPS100
Protection - V x I
• 32, 132: Forward or Reverse, Over or
Under Power (Under with user supplied logic)
– Use for Loss of Prime Mover
– Online indication
– Sequential tripping
• 40Q, 140Q: Loss of Excitation
– Definite Time
– Offset Sloped VAR Flow Algorithm
– Set one Fast/High; 2nd Slow/Low
BE1-GPS100
Auxiliary Timers
• 62, 162, 262, 362: General Purpose
Logic Timers
– Multiple Modes of Operation
*
*
*
*
*
Pickup / Drop Out
One Shot, Retriggerable
One Shot, Non-retriggerable
Integrating Timer
Latch
– Very Long PU and DO Time delays
* 0.000-9999s (2.78hrs)
BE1-GPS100
Control
• Virtual Control switches in the relay
replace panel mounted switches
– Controllable from relay HMI or via
serial ports
– 101 Breaker Control switch
* 3 Outputs: 101T (Pulse Trip), 101C (Pulse Close),
101SC (Slip Contact)
– 43, 143, 243, 343 switches
* 3 modes: On / Off; Off / Momentary On; On / Off / Pulse
* User settable labels
BE1-GPS100
Switchable Setting Groups
• Two settings groups for addressing
different operating conditions
– Controlled via Programmable Inputs
– Control via 43 switches
– Settings are independent
– Setting Group can change logic
Typical One Line
BE1-GPS100
PRIME
MOVER
G
FIELD
GND
FLT
LOGIC
3RD
151N
27X
159P
159X
32
24
132
27P
81
40Q
47
181
140Q
59P
281
159P
381
3Vo
59X
IN2
SIMULTANEOUS
TRIP
101
(T)
51V
TIMER
Unused
Functions
25
IN4
127P
143
50BF
243
127X
343
SEQUENTIAL
TRIP
IN3
43
46
60FL
50P
50N
51N
I.E.
LOGIC
IN1
BE1-GPS100
•
•
•
•
•
Metering Functions
Volts: ph-ph, ph-n
Amps: Ph, N, Gnd, Neg Sequence
Watts, VARS, Forward/Reverse
Watt-Hours, VAR-Hours
Read from
– BESTCOMS
– Front HMI
– ASC commands
– SCADA access via com. ports
Metering Functions
BE1-GPS100
Metering Functions
• Demand
– Amps: per phase, ground, negative seq.
– Watts, VARs, Forward / Reverse
– Demand Alarms
– Today's, yesterday's, peak since reset
– Demand interval separately settable for
phase, neutral, and negative sequence
BE1-GPS100
Settings File Documentation
• Use BESTCOMS to print or export
all settings with a single click
• Five pages of detailed settings
• Fast and easy settings documentation
BE1-GPS100
Detailed Event Reports
• 16 Fault Summary Reports
– Includes tripping elements, targets,
current, voltage, duration
• 255 Sequence of Events
– SOE includes all logic changes of state
and all protective element and I/O pu/do
• 240 Cycle Oscillography
– View with free BESTwave software
– Divided over 6-16 events (user setting)
– 12 samples / cycle
BE1-GPS100
Alarms
• 4 Types of Alarms:
– Relay Fail, Major, Minor, or Logic
• Front Panel includes LEDs for
Relay Trouble, Major, and Minor Alarms
• Relay Fail Contact Output
• Continuous self test
• Reset alarms via Contact Input or
Logic command
BE1-GPS100
Breaker Monitoring
• Accumulation of interrupted I or I
• Provisions to disable breaker duty
2
during test current injection
• Operations counter
• Excessive clearing time
• Built-in trip circuit monitor (Output 1)
BE1-GPS100
•
•
•
•
•
•
•
•
I/O
3 Phase CTs, 1 or 5 A
Optional Independent Gnd CT, 1 or 5 A
3 Phase VTs, 3W, 4W, or 1 Ph
1 Aux VT (Gen Neutral or Bus)
4 Programmable Status Inputs
5 Programmable + 1 Alarm Outputs
3 Communication Ports
Front Panel: LCD display with 5 virtual
switches
BE1-GPS100
•
•
•
•
Advanced Human Machine Interface
Programmable scroll list
You can't get lost in the menu tree
Automatic priority of target and alarm displays
Most settings changeable via HMI
– Logic setup requires com. port access
BE1-GPS100
Integration Friendly Features
• Virtual Switches replace physical
switches for local and remote control
• Metering, Alarm, and Status Reporting
• Three Independent Communications
Ports with optional protocol support
– Modbus
– DNP 3.0 Level 2 Certified
BE1-GPS100
•
•
•
•
Communications
Three independent general purpose com ports
All are optically isolated
ASCII command communications
Free Windows based software included for
setting and interrogation of the relay
• Protocol support for Com2
(RS-485 port on rear)
• IRIG-B port is standard (external time sync)
BE1-GPS100
Security
• Three access areas with independent
passwords
• Master access password
• Security independently settable for
each port
BE1-GPS100
Hardware Features
• Flash memory for embedded
programming
• Active CT technology
• Power supply holds up to 100ms with
4 output relay energized upon complete
loss of power
• Full drawout half rack and S1 case
BE1-GPS100
Mounting
Half Rack Case (H1)
Mounting Accessories
Two Escutcheon Plates available:
•
•
Panel mounts one H1 type relay
Panel mounts two H1 type relays dovetailed
side-by-side
Two Adapter brackets available:
• Mounts single H1 case relay in a 19” rack
–with cutout for FT test switch
–without cutout for FT test switch
BE1-GPS100
What about mounting?
S1 Case with Test Paddle
Mounting Accessories
Fits in same size cutout as Basler and GE S1 case
Available in S1 single and double ended Cases
Two Adapter Plates available:
•
•
Mounts S1 case in GE S2 or West. FT21 cutout
Mounts S1 case in West FT32 cutout
BE1-GPS100
Windows Software
Free BESTCOMS™ with Every Relay
• System Setup Summary Screen shows
all enabled functions
• Screens are provided for the
operational setting of each protective
function
• Screens are provided to aid making
BESTlogic settings
BE1-GPS100
Windows Software
Free BESTCOMS™ with Every Relay
• System Setup Summary Screen shows
all enabled functions
• Screens are provided for operational
setting of each protective function
• Screens are provided to aid making
BESTlogic settings
BE1-GPS100
Windows Software
Free BESTCOMS™ with Every Relay
• System Setup Summary Screen shows
all enabled functions
• Screens are provided for the
operational setting of each protective
function
• Screens are provided to aid in making
BESTlogic settings
BE1-GPS100
FLEXIBILITY
Application Logic
BESTlogic
• Highly flexible programming language
• Equivalent to combining discrete
component with user defined Boolean logic
• User has the same flexibility as in the days
before multifunction relays
• Evaluation effort is reduced
BE1-GPS100
FLEXIBILITY
Application Logic
• User defined Inputs and Output
Application
– Customize to application
• User defined variable names
– Easier to analyze event reports
– Allows virtual switch name to be
customized to application
BE1-GPS100
BESTlogic
Select a Pre-programmed Scheme
OR
Program a Custom Logic Scheme
BE1-GPS100
BESTlogic
Example: Virtual Selector switch
Mode =
0 - disable
1 - on/off or pulse
2 - on/off only
3 - pulse only
HMI or
Communication
Port Command
43
10 character User
defined name for
switch
7 Character
User defined name
for OFF state
7 Character
User defined name
for ON state
Virtual switches: 43, 143, 243, 343
BE1-GPS100
BESTprint
• BESTPRINT allows users to preview
and print graphical representations of
BESTCOMS settings files.
• 15 pages of detailed documentation
BE1-GPS100
Questions?