Automation and Drives - Siemens Industry Inc
Download
Report
Transcript Automation and Drives - Siemens Industry Inc
Automation and Drives
SITOP power flexi
The power pack handles it all - from 3 to 52V
SITOP power
SITOP power flexi
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
SITOP power facets
A&D SE PS 22.01.2003
1
Automation and Drives
SITOP power flexi
Special features
SITOP power
SITOP power flexi
Output voltage adjustable from 3 to 52 V
By using a potentiometer or analog input signal (0 to 2.5 V)
Can even be adjusted dynamically during operation
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
Max. output current adjustable from 2 to 10 A
By using a potentiometer or analog input signal (0 to 2.5 V)
Current monitoring
Output current depending on the analog signal (0 to 2.5 V)
Red LED indicates when the set current limit is reached
Additional functions
Automatic power limitation to 120 W
Sense line for precise voltage to power load
Power-ok signal provided as a relay contact
Power-fail signal
SITOP power facets
A&D SE PS 22.01.2003
2
Automation and Drives
SITOP power flexi
Application areas and customer advantages
SITOP power
SITOP power flexi
SITOP power dual
One device for different applications
Lower logistics costs
Easier to configure
Easier to service
SITOP power 0.5
2-phase 20A
In SIMATIC design
Standard device instead of special power pack
DC/UC- Input
For AS-i
For “non-standard” voltages between 3 and 52 Volt
For applications, with a need for a direct current, which can
be changed dynamically
lab applications, testing systems, control of DC motors etc.
For load control with integrated current monitoring
As battery charger due to adjustable current limitation
All the advantages of a standard SITOP power device
(e.g., industrial capability, ready to use, high quality,
compliance with all pertinent international standards,)
Comparable price to standard Dc 24V/ 100 watt unit
SITOP power facets
A&D SE PS 22.01.2003
3
Automation and Drives
SITOP power flexi
Output characteristic
60
SITOP power flexi
50
SITOP power dual
40
SITOP power 0.5
2-phase 20A
Volt
SITOP power
30
1)
20
In SIMATIC design
2)
10
DC/UC- Input
0
For AS-i
0
2
4
6
8
10
12
Ampere
1) Range of adjustment for output voltage
2) Range of adjustment for current limiting
SITOP power facets
A&D SE PS 22.01.2003
4
Automation and Drives
SITOP power dual 15V
Mounted quickly, even at ±15 V!
SITOP power
SITOP power flexi
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
SITOP power facets
A&D SE PS 22.01.2003
5
Automation and Drives
SITOP power dual 15V
Special features and customer advantages
SITOP power
Industrial-capacity, compact device for the switching cabinet
SITOP power flexi
Wide-range input (93 to 264 V AC) for worldwide use
Two floating outputs (15 V DC/3.5 A)
SITOP power dual
SITOP power 0.5
2-phase 20A
Can be used in parallel for 15 V/ 7 A (single output)
In series for ±15 V/ 3.5 A (dual output)
In SIMATIC design
DC/UC- Input
Simple compensation of power losses
Outputs adjustable from 14.5 to 17 V with potentiometer in front
For AS-i
Extremely easy to handle
Fast mounting on standard DIN rail
Easy wiring
SITOP power facets
A&D SE PS 22.01.2003
6
Automation and Drives
SITOP power dual 15V
Application areas
SITOP power
SITOP power flexi
General mechanical engineering
Powering of electronics
Powering of operation amplifiers
SITOP power dual
SITOP power 0.5
2-phase 20A
Laser processing machines
Powering of deflection mirrors of laser heads
(e.g., with laser inscribers)
In SIMATIC design
DC/UC- Input
For AS-i
Measuring technology
Powering of measuring converters
SITOP power facets
A&D SE PS 22.01.2003
7
Automation and Drives
SITOP power 0.5 - Power out of 22.5 mm
Ideal for low-voltage switchgear
SITOP power
SITOP power flexi
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
SITOP power facets
A&D SE PS 22.01.2003
8
Automation and Drives
SITOP power 0.5
Special features
SITOP power
AC version: 24 V/ 0.5 A
DC version: 24 V/ 0.375 A
Wide range input
SITOP power flexi
SITOP power dual
SITOP power 0.5
AC version:
Urated= 120 - 230V AC
(87 ... 264V AC)
DC version:
Urated= 48 - 220V DC
(30 ... 264V DC, 30 ... 187V AC)
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
Width: 22.5 mm
Weight:
0.11 kg (AC) / 0.14 kg (DC)
Temperature range:
-20° to +70° C
SITOP power facets
A&D SE PS 22.01.2003
9
Automation and Drives
SITOP power 0.5
Customer benefits
SITOP power
SITOP power flexi
Space savings
Due to narrow width and minimum space requirement
Optimal for use in switching cabinet
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
Cost savings
Due to use of 24 V standard contacter and relay types
for "odd" voltages
Due to reduced number of models because of
wide-range input
Time savings due to availability from warehouse
Worldwide use
Certifications in according with UL and cUL
SITOP power facets
A&D SE PS 22.01.2003
10
Automation and Drives
SITOP power 2-phase 20A
For high network voltages
SITOP power
SITOP power flexi
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
SITOP power facets
A&D SE PS 22.01.2003
11
Automation and Drives
SITOP power 2-phase 20A
Special features and application areas
SITOP power
24VDC /20 A DC for 3-phase networks in 480 and 575 VAC
SITOP power flexi
2-phase power supply
SITOP power dual
SITOP power 0.5
2-phase 20A
Wide- input voltage range from 420-682 VAC for ...
In SIMATIC design
DC/UC- Input
For AS-i
No need for line protection of third phase
Single phasing doesn‘t require additional protection devices
as recommended with 3w-phase power supplies
575 VAC 3-phase networks in the USA and Canada
Highest protection against voltage fluctuations in case of unstable
network conditions
Adjustable output voltage from 22.8 to 28.8 V
Devices can be switched in parallel
Provides agency approvals for the North American market
UL, cUL, CSA
SITOP power facets
A&D SE PS 22.01.2003
12
Automation and Drives
Power supplies in SIMATIC design
SITOP power
SITOP power flexi
SITOP power dual
Optimal for SIMATIC S7-200
AC 120/230 V, 24 V/ 3.5A
RFI specification class B
Parallel connection possible
SITOP power 0.5
2-phase 20A
In SIMATIC design
DC/UC- Input
For AS-i
Slim like the SIMATIC ET200B
AC 120/230 V,
24 V/ 5 A and 10 A
Optimal for use with
distributed I/O device
Minimum width requirements
when used with a mounting
bracket (2.5 inch width even
for 10 amp unit))
SITOP power facets
A&D SE PS 22.01.2003
13
Automation and Drives
Power supply with degree of protection IP65
Optimal for the SIMATIC ET 200X
SITOP power
Single phase 120/230 VAC,
24 VDC/10A
Design adapted to
SIMATIC ET200X
SITOP power flexi
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
24 VDC via screw-type
terminals for loads
Choice after short circuit:
DC/UC- Input
For AS-i
24 VDC via back plane bus for
electronics/ encoders
and/or load
Automatic restart
Switch off
For use under roughest
conditions from -25 to +55°C
Can be installed in any
position
SITOP power facets
A&D SE PS 22.01.2003
14
Automation and Drives
SITOP power
with direct current and universal connection
SITOP power
Direct current input (DC/DC 2A)
SITOP power flexi
For 48/60/110 V battery networks
via DC input 38 to 121 V
SITOP power dual
SITOP power 0.5
Universal connection
(2.5/4/10 A)
2-phase 20A
For 120 V and 230 V power
networks without switching
thanks to wide-range input
range from 93 to 264 V AC
For 220 VAC - battery systems.
DC operation within 110 to 350 V
possible
In SIMATIC design
DC/UC- Input
For AS-i
Parallel connection for
redundancy and power
increase
Design adapted to
SIMATIC AG 95/100 (2.5/ 4A)
SITOP power facets
A&D SE PS 22.01.2003
15
Automation and Drives
Power supplies for AS-interface
SITOP power
30 VDC /2.4 A in class of protection IP 65
Input voltage
from 20.4 to 28.VDC
Only 57 mm mounting depth
No mounting restrictions
Ambient temperature
from -25° to +55°C
SITOP power flexi
SITOP power dual
SITOP power 0.5
2-phase 20A
In SIMATIC design
30 V/7 A with wide input voltage range from
DC/UC- Input
93 to 264 VAC or 110 to 350 VDC
Can be snapped on standard DIN rail or specific S7-300 rail
For AS-i
Data buffering according to
the AS-i specification
Also suitable for public
low voltage networks
SITOP power facets
A&D SE PS 22.01.2003
16