Data Acquisition System for the AESD
Download
Report
Transcript Data Acquisition System for the AESD
ARD, Carderock Division, Bayview,ID
Project Professors: Dr. Herb Hess & Dr. Brian Johnson
DATA ACQUISITION
SYSTEM FOR THE AESD
DETAILED DESIGN REVIEW
SEPTEMBER 30, 2008
Team : SEADAQ
Members: Jarred Coulter
Zane Sapp
Vishu Gupta
Overview
2
Goals for Fall 2008
Design
Goals
Timeline- Fall 2008
Accomplishments to date
Sensors
LabVIEW
Programming
DFMEA
Work to be completed
Questions
Goals for Fall 2008
3
Design goals
Timeline: Fall 2008
Design Goals
4
Switching Scheme for Controlling Sensors
Disconnect input from batteries
Disconnect output from DAQ
LabVIEW Programming
Data Management
GPS Interface
Location stamping
GPIB Interface
Temperature data
Testing/Calculations
Latency and Power Consumption
Cost per channel and BW for multiple chassis configuration
Timeline: Fall 2008
5
Accomplishments to date
6
Redesigned Voltage Sensors
LabVIEW Programming
DFMEA
Sensors
7
Redesigned Voltage Sensors
Less
power consumption
Only one voltage reference
Simplified design
Linear input to output
Voltage Sensor Schematic
8
Voltage Sensor Simulation
9
LabVIEW Program for the DAQ
10
Program to control the DAQ and manage the data.
Easy
Control for data acquisition
Display data real-time
Save the data to a file in a specified location
Data available outside LabVIEW for viewing/analysis
Flow Diagram of the Program
11
Front Panel: Control
12
Front Panel: Error
13
Front Panel: Output Display
14
DFMEA
15
Work to be completed
16
Thermocouple interface
GPS
Testing and Calculations
Latency
LabVIEW programming
Switch
and Power consumption
Control
Multi-Chassis configuration
Star
or series connection
Meeting
with NI Engineer on October 9th.
Questions
17