PowerLogic ® E5600 - Schneider Electric

Download Report

Transcript PowerLogic ® E5600 - Schneider Electric

®
PowerLogic
power and energy meter
E5600
A PowerLogic system can help you…
Submeter and bill tenants and departments
● Accurate, economical energy monitoring lets you bill tenants for their actual
usage and eliminate previously uncontrolled utility expenses.
Accurately allocate costs
● Monitor individual cost centers, identify opportunities for demand control, and
check energy consumption patterns. Its low total cost of
cost of ownership means you can easily place a
PowerLogic E5600 wherever you need it.
Reduce energy costs
● Verify the effectiveness of energy efficiency efforts by
monitoring key points within your power distribution system.
Collect the data you need to ensure contractual obligations
are met and use the PowerLogic E5600 to help achieve
LEED certification and green building status.
Schneider Electric - North American Operating Division
2
E5600 Product Overview
● Easy to specify, install and wire
● Economical to purchase and own
● Simple to configure and use
● Revenue accurate energy and
power measurements
● High quality construction and self diagnostics
enhance reliability
● Industry-standard communications
● Excellent upgrade path helps you save money
on future expansion
●Part of a complete tenant metering solution
Schneider Electric - North American Operating Division
3
Target customers
An ideal choice for:
●Office buildings
Buildings
●Multi-use commercial
●Malls
Retail
●Retail operations
●Hotels
Multi-Residential
●Multi-use residential
●Airports
Transportation
●Other transportation facilities
●Universities and colleges
Institutions
●Government facilities
Schneider Electric - North American Operating Division
4
Features and benefits
Economical to purchase, own and install
●S-base socket compatibility enables easy
retrofit into your existing metering
infrastructure
●Self diagnostics and an auto ranging power
supply reduces potential wiring errors and
installation costs.
●A simple interface and standard
configuration software get you up and
running quickly
●Easily replace electro-mechanical meters
with the accurate, solid state PowerLogic
E5600
Schneider Electric - North American Operating Division
5
Features and benefits
Supported S-Base meter socket form factors include:
Self-contained, class 200 in forms:
● 2S
● 12S
● 16S
Transformer rated, class 20 in forms:
● 9S
● 36S
● 45S
Schneider Electric - North American Operating Division
6
Features and benefits
View system data through the easy-to-read LCD screen
● The meter displays measurement data in numeric values, potential
indicators, nominal service voltage, service type, power quadrant
status, energy flow and name plate data.
● An alternate display provides diagnostic
information.
Schneider Electric - North American Operating Division
7
Features and benefits
High accuracy measurements
● Meets ANSI C12.20 accuracy standard, a nationally
recognized sub-metering benchmark
● Eliminate bulk energy billing and allocate costs to
suites, tenants and departments based on their
actual use
● Use energy cost tracking and tenant billing to
improve tenant retention and quality, meet regulatory
requirements and increase property value
● Onboard memory of 128KB provides 82 days of
logged data
Schneider Electric - North American Operating Division
30% energy savings
in a building can
reduce overall
operating cost
by 10%
8
Features and benefits
Industry standard communications
● Standard Modbus serial protocol
eases billing software, energy
management and building
automation system integration
● Improve efficiency by eliminating
manual meter reading
● Enhance future expansion
possibilities and reduce the costs
associated with proprietary protocols
Schneider Electric - North American Operating Division
9
Meter characteristics (front panel)
LCD display screen
ANSI C12.18 Type II front
panel optical
Anti-tamper (revenue) lock
Schneider Electric - North American Operating Division
10
Meter characteristics (rear connections)
Current inputs C B A
Voltage inputs
Input/output and
Modbus RS485 cable
Current outputs A B C
Schneider Electric - North American Operating Division
11
Meter characteristics
● Meter forms.
● Self-contained class 200 in form 2S, 12S, and 16S
● Transformer rated class 20 in form 9S, 36S, and 45S
● S-based socket meter.
● Auto-ranging voltage inputs for direct connection of 120 - 480V
● Supports 4-wire wye, 3-wire wye, 3-wire delta and single phase
● Starting Load:
● Class 20: 0.005 amps
● Class 200: 0.050 amps
● Power loss duration @ Vn – 100msec minimum.
● High Voltage Line Surges ANSI/IEEE C62 (6kV).
● Surge Withstand Capability (ANSI C37.90A).
● Oscillatory: 3 kV
● Fast Transient: 5kV
Schneider Electric - North American Operating Division
12
Meter characteristics
● Overvoltage Withstand:
● Temporary (0.5 seconds): 150% of rated voltage
● Continuous (5 hours): 130% of rated voltage
● Smoked polycarbonate case.
● Environmental.
● Operating temperature: -40 to 176 oF (-40 to 80 oC)
● Humidity:
5% to 95% non-condensing
● Communications.
● RS485 serial interface with six foot interfacing cable – flying leads
● ANSI C12.18 communications interface
● Utility Grade.
● ANSI C12.20, class 0.2
● Security.
● Multiple levels of security available via physical seals and passwords
Schneider Electric - North American Operating Division
13
PowerLogic software
A comprehensive range
of cost effective, easy-touse software for and end
to end billing solution.
PowerLogic ION Setup

Installation set up and meter
configuration software included
with the PowerLogic E5600
PowerLogic Tenant Metering Commercial Edition






Real & reactive energy
Flat & tiered rates
Demand & power factor
Seasonal rates
Time of Use
Miscellaneous charges
Schneider Electric - North American Operating Division
PowerLogic ION Enterprise




Scalable for system growth
Integration with 3rd party meters,
equipment and web services
Data sharing with BAS and business
systems
Advanced power quality analysis,
reporting and control capabilities
PowerLogic System Manager
Software




Real time readings
Load profile upload
Resets for date/time and demand
Advanced power quality analysis,
reporting and control capabilities
14
Complete tenant metering solution
PowerLogic E5600 – the right meter for office, retail,
campus, and government tenant metering applications
● Cost effective:
● Low cost of ownership enables placing meters wherever needed
● Easy installation:
● Configuration and diagnostic tools simplify installation into existing utility
sockets utility
● Utility grade accuracy
● Allocate cost and provide accurate tenant billing
● Power and energy readings:
● Achieve LEED and energy star certification
● Tenant Metering Commercial Edition Software:
● When combined with the PowerLogic E5600 completes the sub-billing
solution
● Support and services
● Optimize your PowerLogic system with our technical expertise and
industry knowledge via the technical support, customer training or
engineering services groups.
Schneider Electric - North American Operating Division
15
For more information, visit . . .
PowerLogic.com
Schneider Electric - North American Operating Division
16