Power Saver R Y B R Y B

Download Report

Transcript Power Saver R Y B R Y B

Company
Company
Established in 1992.
Started by visionary Engineers & Entrepreneurs with
Proven Power Electronics background.
Committed to energy conservation.
Made a humble beginning with florescent light chokes
that conserve energy.
Committed to environmental protection.
Conscious of social responsibility.
Objective
Objective
To be a pioneer in the development &
manufacture of products & technologies
aimed at energy conservation and help the
society towards sustainable development
Focus
Focus
To develop technology intensive, high MTBF
low MTTR, custom-built & user-friendly products
Products
Products
Servo
Stabilizers
APFC panels
Power Savers
UPS
Accreditations/ Approvals
Accreditations/Approval
s
Power Savers
Power Savers
Effect of Voltage variation on lamps*
Effect of Voltage variation on lamps*
Lamp
10% Lower Voltage
10% Higher Voltage
Fluorescent Tube lights
Light output
Decreases by 9%
Increases by 8%
Power Input
Decreases by 15%
Increases by 18%
Light output
Decreases by 20%
Increases by 20%
Power Input
Decreases by 16%
Increases by 16%
Light output
Decreases by 30%
Increases by 30%
Power Input
Decreases by 24%
Increases by 26%
HPMV Lamps
HPSV Lamps
*Source: Bureau of Energy Efficiency
Hence Voltage reduction is not the real solution,
we need optimum voltage
Operation Principle
Operation Principle
* Applied for Patent
MS-27 Power Savers introduce low-loss impedance path
between the source and the load, which causes
maximum power transfer in the circuit that results in
substantial saving in power consumption.
Operation Principle
Operation Principle
Maximum power transfer through impedance matching
& Optimum Voltage
Rv:
Motor IV Curve
Variable Impedance
Ri
Load
Internal
Impedance
Current
Vo
+
_
Voltage
Operation Principle
Operation Principle
Voltage Vs Current Waveforms for
different loads
90 Degrees
45 Degrees
+
+
Voltage
Voltage
Current
Current
0
0
-
-
Purely Inductive Circuit
Circuit with equal values of Resistance and Inductances
For Pure resistive loads current is in phase with voltage.
For Capacitive loads current leads the voltage.
Operation Principle
Operation Principle
KW (Active Power)
KVA
(Total Power)
PF =
KW
___
= Cos
KVA
KW, KVAR & KVA Vector
KVAR
(Reactive Power)
Power Saver Block Diagram
Power Saver Block Diagram
CIRCUIT
BREAKER
Y
CHANGE
OVER
SWITCH
R
R
Y
B
HARMONIC
FILTERS
R
Y
Y
APFC
LOAD
POINT
B
B
R
Y
B
IMPEDANCE
MICRO
CONTROLLER
Power Saver in Electrical Distribution
Power Saver in Electrical Distribution
A.P.S.E.B
METER
H.T 11KV/33KV
RED
C.T.COILS
L.T.
PANEL
YELLOW
BLUE
R
Y
B
POWER
SAVER
R
Y
B
LOAD
POINT
Types
Types
Energy Savers
Coil Based
Servo Motor Based
For limited supply fluctuations
For high supply fluctuations
Single Phase: 1to 45 KVA and multiples
Three Phase: 5 to 150 KVA and multiples
Single Phase: 1to 45 KVA and multiples
Three Phase: 5 to 150 KVA and multiples
Features
Features
Micro Controller based technology
Efficiency > 99%
On load manual by pass switch
Custom-built
MTBF > 1,00,000 Hr.
Low MTTR
Features
Features
Rugged construction meeting industrial standards
Good thermal management
Ultra-low maintenance.
Life of over 15 years
Available in indoor and outdoor models
Input & Output protection by SFU/ MCB/MCCB
Features
Features
Optional
Tap changing switches in coil based systems
Automatic low voltage bypass
Automatic high voltage cut-off
Automatic over load by pass & auto walk-in
Data logging with RS 232 remote monitoring
Power Analyzer software
Data Logging
Data Logging
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Power Analyser
Benefits
Benefits
Reduction in power consumption (KWH)
Immediate Cash savings
Improvement in power factor
Incentives from the Electricity board
Reduction in maximum demand
More Power Available – Lower capital
costs
Increase in the life of the equipments
(Loads)
Lower maintenance & replacement costs
Reduced Power generation
Low Green House gas emission – Clean
environment
100% value depreciable in the
first year itself under Income
Tax Rules in vogue in India.
Tax savings
Savings
Savings
Slash your electricity bills with Entek MS-27
Savings :
Lighting Loads 20 to 30%
Motor Loads
10 to 15%
Mixed Loads
15 to 20%
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Credentials
Case Study
Case Study
CUSTOMER : HOTEL QUALITY INN, HYDERABAD.
Load description
Units consumed
without Power
Saver for 1 Hr.
Units consumed
with Power
Saver for 1 Hr.
Savings
45 Lighting
12.93
10.81
16 %
30 Lighting
19.15
14.82
22 %
50Tr. New AC
44.82
36.726
18 %
50Tr. Old AC
45.04
37.36
17 %
100Tr. AC
89.54
80.20
11 %
Pump
13.42
10.33
23 %
Pay-back period calculations
Pay-back period calculations
1)
Total connected load
: 340KVA
2)
Running load
: 220KVA
3)
Working hr per day
: 16 Hrs
4)
No. of working days/m
: 30 Days
Power consumption = KVA x No. of working hr/day x No. of days/month
= 220 x 16 x 30 = 105600 Units/month
Per Unit rate
= 4.50 per unit
Power bill per month = Units consumed x Rate/Unit
= 105600 x 4.50
= Rs.4,75,200
Average power saving by installing Power Saver
Units saved/month
= 105600 x 18% = 19,000 Units
= 19,000 x 4.50
Payback period
= 18%
= Rs.85,550/-
= Investment/ Monthly Savings
= 1190000/85,550
= 14 months (apx)
Pay-back period calculations
Pay-back period calculations
Other Benefits:
•
Reduction in demand charges
= 20%
Maximum demand
= 340KVA
Billed demand
= 272KVA
= 81,600
Reduction in demand charges
2)
Power factor incentive 5% on the billed units
1,05,600 x 5% = Rs.5,280/-
3)
100% Income Tax depreciation
= 16,320
Welding Machine – Power Saver
Welding Machine – Power Saver
R
Y
B
Power
Saver
R Y
1.
When welding process is idle
for >30 sec the supply to Tx is
cut-off
2.
When the welding rod is
tipped to the earth rod the
supply to Tx is restored.
B
Welding
Transformer
Welding
Electrodes
Growth partners
Kalanikethan
Hotel Aditya Park Inn
Raj Breeders (P) Ltd
Madhu Beverages
Aruna Agencies
Mediland Transtech (P) Ltd
Manhar
Uvma Holiday Inn
COMESUM
Bhimas Residency Hotels
St. Joseph’s Hospital
Jyothi Theatre
Real Bakers Pvt Ltd
Meena Bazaar
Sidhi Jewelers
R.S.Brothers
Ambica Food Plaza
Shreyas Multi Special Hospital
Mid India Enterprises (P) Ltd
Sneha Farms (P) Ltd
Global Energy Food Industries
Vishal Retail Mega Market
R.S.Silks
Viswanath 70mm Theatre
Metro Recreation (P) Ltd
Tirumala Residency Hotel
ANR Shopping Mall
Karachi Bakery
Bharat Cafe
Royal Hatcheries (P) Ltd
Sanghvi Sales Corporation
Bommana Rajkumar
Glenn View Rubber Co.
Shinewell Engineering P Ltd
Priyadarshini Hotels (P) Ltd
G V R Children’s Hospital
Jyothi Studio
FAQ’s
FAQ’s
Q.Where do you locate the Energy Saver?
A.For achieving maximum Savings the Energy saver must
be as close as possible to the load point, so that line
drops will be lower.
Q.Can we have single system for 200 KVA & above
A.Energy savers for individual loads are more ideal because
impedance matching is more accurate in such cases and
line losses can be reduced by locating close to the load.
FAQ’s
FAQ’s
Q.If we already have APFC Panel installed do we still need an Energy
Saver?
A.Yes! APFC Panel is a mandatory requirement of SEBs, installed
near the Trivector meter primarily to reduce the Demand. How ever
Energy Saver is installed close to load point and helps reduce the
consumption.
Q.Why do you need a Data Logger?
A.Data Logger helps in monitoring and logging the variation in the
load and helps in load analysis and remedial actions.
FAQ’s
FAQ’s
Q.Can we show savings in all cases?
A.
a) In Low voltage areas Energy saving depends on the load
nature and is not assured
b) When motors are operating at full load the savers may not be
very effective.
c) Electro Mechanical (Traditional Moving Coil) Meters: Though
savings are high actual readings/utility bills do not substantiate
the savings fully.
d) Intermittent operations also may not have effective savings
FAQ’s
FAQ’s
Q.What is the difference between Variable Frequency Drive
(VFD) Savers and Entek Energy Savers?
A. VFD is for Motor Applications only, it varies the frequency
so as to reduce the consumption.
VFD’s introduce harmonics and reduce power factor
Q.How does Electronic ballast compare with “Entek” Power
Saver ?
A. Electronic ballast generates harmonics and induced in the
supply which affects the life of sensitive equipment and it also
reduces the power factor. Entek Power Saver does not
produce any harmonics and improve power factor.
Save today
Survive tomorrow