Cooper-Bussmann-CCP-Customer

Download Report

Transcript Cooper-Bussmann-CCP-Customer

Compact Circuit Protector
Smaller
Simpler
Better
the
protection
in 1/3 the
space
Product Description
Compact Circuit Protector
Backed out Line and Load Terminals
Saves installation time.
Disconnect Switch
Indication Light
For load isolation
Easy troubleshooting tool to help find
the opened fuse quickly
Lock-out/Tag-out
Meets requirements for
maintenance safety procedures
Easy to Turn-lid
No fuse-puller required to
install or extract a fuse
35mm DIN Rail Mount
IEC Marked Line and Load Terminal
For global acceptance
Feature-rich solution!
For quick, snap-on installation
Value - Smaller
CCP is 1/3 the space of equivalent UL489 circuit breakers
CCP is 2/3 the space of traditional fusible disconnects
MCCB Size reduction: 69.7%
CCP
Fusible
Disconnect
MCCB
Footprint comparison
Fusible Sw Size reduction: 42.3%
Source Eaton FDXXX
Source ABB CFDXXX
Small = Value for the OEM customer
Value - Smaller
Relative size comparison with Circuit Breakers
UL 489
Circuit Breaker
UL 489
Circuit Breaker
UL 489
UL1077
Supplementary
Protector
Cooper
Bussmann
CCP
Circuit Breaker
Small = Value for the OEM customer
Value - Smaller
UL512 Listed Class CC
Fuse Holder with Class
CC Fuses and UL508
Listed Disconnect
Cooper Bussmann
UL98 Listed Class CC
Compact Circuit
Protector with Class
CC fuses
UL508 Listed Disconnect
(Manual Motor) with Class
CC fuses
UL98 Listed Class CC
fusible disconnect with
Class CC fuses
Small = Value for the OEM customer
Value - Simpler
DESIGN
 Promotes higher SCCR
 Full Voltage Rating
 Global standards = global
acceptance
INSTALL
 Fully integrated fuse and
switch
 Clearly marked Line and Load
side terminals
 Terminal screws are backed
out at factory
 DIN rail mount standard
USE
 Local fuse indication built-in
(light)
 Remote fuse indication
accessory (PLC)
 Switch-status accessory
(NO+NC contacts)
 Easy to operate fuse switch
Line and Load Terminals
Fuse
Switch
DIN rail mount
Local Indication
NO+NC Aux Contacts
Value - Better
Standard A/C Voltage Ratings
Standard Interrupting Ratings
MMP
MCB
MCCB
MMP
MCB
MCCB
480/277
120/208
480/277
65kA
14kA
18kA
Unmatched performance in electrical protection
Product Profile
Compact Circuit Protector
Catalog number:
Catalog number:
CCP-1-30CC (1-Pole),
CCP-1-30M (1-Pole),
CCP-2-30CC (2-Pole),
CCP-2-30M (2-Pole),
CCP-3-30CC (3-Pole)
CCP-3-30M (3-Pole)
 Applications:
 Applications:
Motor Circuits
Control circuits
Heating and lighting





Global Acceptance
30A/ 600vAC
200kAIC rating
Accepts Class CC only
UL98
Horsepower Rated
 32A/ 600vAC
 Suitable for Global
applications
 Accepts IEC 10x38, 32A
Am, 25A Gg or Class CC
 IEC 60947-3 AC23A
 UL 508
Three basic models
Catalog number:
CCP-1-DCC (Class CC fuse, 1-pole)
CCP-1-DCM (Midget fuse, 1-pole)
 Applications:
Control Circuits
 80vDC
 Blue handle clearly
identifies DC circuit
 Available in two skus: CC
and 10x28 models to
support global
installations
Product Profile
Agency Listings
Package size:
17.5mm [.689in] wide / Compliant to DIN 43 880
Maximum operating
voltage and listings:
600Vac / 80Vdc UL98 Listed for class CC fuse.
600Vac / 80Vdc UL508 recognized, IEC 60947-3 AC23A for
10x38 IEC and Midget fuse.
Switch rating:
32A IEC 60947-3 AC-23A / 30A UL98 & CSA22.2 #4
Horse Power rating:
7.5Hp@600V, 5Hp@480V, 3Hp@ 240V, 2Hp@200V w/CC fuse
SCCR:
200kA UL class CC
Frequency:
50-60Hz
Wire Range:
18-6AWG 75C CU only solid and stranded single and dual
4AWG single
*CCC (China) Listing Under Investigation
Listed to UL, CSA and IEC standards
Product Profile
Accessory: Remote Fuse Indication
Catalog number:
CCP-PLC-IND
Switch
Connects to CCP
Disconnect Switch
Pre-Wired Phase
Monitoring Conductors
Two Indication LEDs
Green LED indicates unit power
Red LED indicates Open Fuse
Signal Connections to
Monitor/ Control
Includes 0 .110” quick connects for power,
signal and ground connections.
24vDC remote indication
Includes spade terminals to
connect to CCP
Product Profile
Accessory: Remote Fuse Indication
Remote Fuse Indication Accessory
Installation to CCP
Wiring to CCP
Phase monitoring conductor
dedicated wiring terminal
• Mounts on left side of CCP
• Necessary hardware is provided.
• Dimensionally Compliant to DIN43880
• Dedicated terminal on the CCP to
accept the conductor.
• For 1-pole or 2-pole CCP
connection, trim unused conductors
from the device.
24vDC remote indication
Product Profile
Accessory: Auxiliary Contact for Switch Status
Contact Rating
Catalog number:
CCP-AUX
5A/240vAC
Auxiliary Contacts
Switch
One NO+NC Contact for Switch
Status
Connects to CCP
Disconnect Switch
Indication of CCP switch position for interlocking
Product Profile
Accessory: Auxiliary Contact for Switch Status
Auxiliary Contact for Switch Status Accessory
Installation to CCP
• Mounts on right side of CCP
• Mechanically interlocks with the CCP
switch handle with hardware provided..
• Dimensionally Compliant to DIN-43880
Easy to install accessory
Challenge!
Tools for Selling
Application Note
Comprehensive volume of application knowledge
Challenge!
Tools for Selling: Application Note
Best fused solution!
Challenge!
Tools for Selling: Application Note
Better ratings than circuit breakers
Challenge!
Tools for Selling: Application Note
Control Circuit
Applications
Higher ratings achieved in control circuits
Challenge!
Tools for Selling: Application Note
Resistive and
Lighting
Circuit
Applications
Higher ratings achieved at competitive cost
Challenge!
Tools for Selling: Application Note
Motor Circuit
Applications
Better ratings for motor circuit applications
Summary
New category designed to help you
 Save space
 Increase SCCR ratings
 Improve safety
 Reduce downtime
Thank You