Three-Phase Power Quality
Measurement Products
PA-9
1
PA-9
DESIGN OBJECTIVES
 Use The Latest Technology To Deliver the Highest
Performance At Lowest Price.
•
•
•
•
One of the Most Powerful Digital Signal Processors.
Co-Microprocessor Design.
Utilizes Low Cost, Hi-Density Digital Camera Memory.
Utilizes High Performance Graphical Display.
 Update Future Features via Flash Reprogrammable Firmware
 A Worldwide Product
• CE Approved (Completed with current PA-9Plus)
• Expand to meet Relevant IEEE/IEC Standards
– EN 50160, 61000 4-30, 61000 4-15 and IEEE 1159
• Support multiple languages
– English and French now, with Spanish to follow
– Others as required
2
Result: The PA-9
Power Analyzer
 Evolving from:
• 17+ Years Experience Manufacturing Power Quality
Monitoring Products
• Listening To Suggestions From Our 600+ Customers
• Experience From Our Very Successful Products like the
PA-9 and PA-7 Power Analyzers (1600 instruments
installed).
 Our Intent:
• Extend This Success Worldwide to Utility and Industrial
Marketplaces
3
The PA-9
Lockable
Hasps
Exterior
Light Rugged polypropylene
Case (12.5lbs or 5.7Kg)
Optional Internal
Modem
4 Voltage
Channels
Auxiliary AC Power Input
(90-270vac/dc) **NOW** Standard
5 Current
Channels
Optional
External RS-232 Port
4
KEY FEATURES
Optional Data Transfer Card
Backlit Graphical
Display
Mouse Type
Navigation
System
Home Key
DB9
RS232
Port
Simplified
Instruction
Sheet
Real Time Display Key
Aux Power Input
5
KEY FEATURES
 4 (Differential) Voltage/5 Current Channels = 9 Total Inputs
 Range: Voltage 600V AC or DC
Current (0-6000 Amps) Based on CT Chosen
(20-6000 Amps)
 256 Samples/Cycle Simultaneously Read On Every Input
Channel (TRMS through 63rd Harmonic)
 Sub-Cycle Event Capture to 65 Microsecond Events
 All Common Connection Configurations Supported for Power
Measurements
 Immediate Local Info and Analysis using onboard Graphical
Display (Waveforms/Charts/Harmonics/Phasors/Flicker)
 Instrument Self-Powers from Either Phase A Voltage (90-600v
AC ,110-600v DC) OR Secondary Power Input Channel
 Field-Update Firmware via Internet
6
KEY FEATURES
 4 Simultaneous Recordings
•
•
•
•
RMS Voltage/Current (Long Term Trend)
Out of Limits Log (for Sag/Swell/Harmonics/Transient Events)
Waveforms (by Event, THD/TDD/Harmonic Trending, or Time)
All Power Flow Parameters
 12MB Non-volatile Internal Memory (No Batteries or Moving
Parts Needed)
 115Kbps RS-232 Maintenance Port
 Optional Internal Modem
 Optional Removable Compact Flash Transfer Memory (No PC
Required to Program Instrument or Retrieve Data)
 Remotely Analyze Data prior to Download, and Selective Data
Download Capabilities
 Weatherproof Package – Portable, Sturdy, and Rugged
7
IEC SPECIFIC KEY FEATURES
 EN 50160 Measurements
 Flicker Per IEC 61000-4-15 For Both 50 And 60 Hz
• Display Pst And Plt Values. Pst On A Sliding One Minute Interval
 Dynamic Frequency Measurements from 20 To 70 Hz
• Trending Of Frequency Based On A Minimum Sliding 5 Cycle Period
• Ideal for Generator Startups




Trending Of Harmonics Up To The 63rd Harmonic
RMS Trending Of All IEC Report Parameters
Low Voltage 4th Channel Standard 0.1 Volt To 500 Volts Peak
Language Support In Pa-9 Plus And Metrosoft
• English and French Available First, Spanish To Follow
 New Metrosoft Supports All New Features With Firmware Included
 Optional New Report Generator For Customer Specific Reporting
8
RMS Recording
 Parameters to consider
• Fast Sampling Rate (Fixed at 256/cycle)
• RMS Response Time (or Integration Time) User Settable
To 1 cycle or longer.
• Storage Interval
–User Settable 1 cycle to 4 Hours. Save Min RMS,
Max RMS, Overall RMS per Storage Interval.
• Standard Cycle by Cycle Recording Capability for Motor
Inrush Studies
 Our Instrument Memory Recording Techniques
Conserve Memory and Guarantees Capture of
Lowest & Highest Signal Values per Storage
Interval.
9
The Scan Line can move to
display values in window
Notice the large current
swells due to a lightning
strike
10
Out-Of-Limits Events Log
 User Sets Following Limits By Channel
• High/Low RMS Limits (both V & I)
• Sub-Cycle Impulse Magnitude.
• THD%
 Recorder Captures up to 1000 Events Outside of
User Preset Limits And Logs Them With Duration In
Out-Of-Limits Log.
11
Stored Data:Event / Out of Limits Data
 Out of Limits- While recording, continuously monitors for
excedances of user defined limits for upper & lower V/I, subcycle (65uS), and THD.
• Monitors all connected channels, for analysis between load /
source side.
12
Waveform Capture
 Waveforms Are Captured Via:
•
•
•
•
Event Trigger
Time Trigger
THD/TDD/Individual Harmonic Trending
User Trigger from Front Panel
 User Specifies Number of Pre-Trigger Cycles
(Max 2) and Number of Post-Trigger Cycles To
Capture.
13
Instrument Front Panel Waveform Display
14
Loss of Voltage
After a Lightning
Strike
15
Applications for PA-9
Waveform Capture - Motor Inrush
 Waveform capture
triggered on Rising Current
• Three phase chiller start-up
inrush.
• Display all captured cycles
on one screen. (Inrush
decay envelop)
• Same click and drag zoom
and scan line features.
16
Real Time Harmonic Analysis
 FFT Done Every 6 Cycles.
 Harmonic Analysis And Direction Of Harmonic
Power Flow Presented On Display.
 Generally A Very Good Indicator Of The Harmonics
Source
17
Harmonic Analysis In Software
Here we see we have a
total THD of 55.5%, with
the largest expected
contributions from the
odd-ordered 5th, 7th, 11th,
and 13th harmonics.
18
Demand Recording
 User Specifies Demand Interval, Fixed Or Sliding
Window, Configuration (Wye, Delta etc).
 All Power Parameters Are Recorded (KW, KVAR,
KVA, pf, dpf etc).
 Power Data Can Be Measured and Recorded As
Fast As Every Cycle
19
Stored True RMS Voltage / Current
 Pa-9+ can display:
• MIN, MAX, and TRMS values
for all channels for entire test.
(Press HOME, select “Stored
Data, RMS Interval”)
• Trending graphs of any
parameter (ex. VA MIN
trended over entire test)
 MEGPA9IEC Software Tabular
Report (right)
• MIN, MAX, & RMS Reported
at every storage interval.
• Data for trending graphs
– with scan line
– click and drag zooming
(next)
20
Demand Data (with power flow option)
 MEGPA9IEC Software allows:
–Printing and exporting of text data reported every
storage interval
–Trending graphs with click and zoom capabilities
–Scan line reporting and vector diagrams (next)
21
Demand Graph with
scan line feature and
vector diagram.
22
MEGPA9IEC Software
 Complimentary 32-bit Software Package available
online (http://www.megger.com)
 Compatible with Win 95/98/NT/2000/ME/XP
 Generates Extensive Graphs/Reports
 Supports Download by Exception
• Preview What Is Recorded Inside PA-9+
• Download Only What Is Needed
 Enhanced Communications Via Serial or Modem
Connections
 Provides Direct Export of Data to Other Windows
Applications: EXCEL or WORD
23
Hardware: User Interface
 115 Kbps communications
port
 Optional Internal Modem
 Fully Graphical display:
• View real time and stored
data (text and graphical)
 12 MB base memory
• Optional Removable
Memory 64, 128, 256,
512MB+ capable
• PC Card Reader Included
 Large, tactile keypad for
easy operation even with
gloves on.
24
Hardware: Packaging
 Rugged enclosure:
•
•
•
•
•
High impact
Smaller package (13x10x6)
NEMA 4X Weatherproof
Lockable hasps
Protective handles on input
connector side.
• Lightweight (15 lbs./ 6.8 Kg.)
• Wide temperature range (-20C
to +50C)
25
Hardware: Voltage Channels
 4 Voltage Channels
• 150/600VAC + DC autoranging.
• Safety banana jack inputs
– Right angle prevents
accidental pull out
– Unfused Leads
Standard, Fused Leads
optional.
• Resolution .1% full scale.
• Accuracy .25% rdg + .05%
full scale.
26
Hardware: Current Channels
 5 Current Channels
• Resolution .1% Full Scale
• Accuracy .25% rdg +.05% range +
probe accuracy.
 Current probes
• CP-6000CE - 600/6000A
– Powered from PA-9+!
– 1% reading accuracy!
• 20/100/1000 CT’s available for
Metering Secondaries or Larger
Current Loads
• Optional Adapter cable mates
most Legacy CT’s to the PA-9
Plus
• On-site CT Selection Directly
Without Reprogramming.
27
Hardware: Power Supply
 90-600VAC or 110-600VDC Operation.
• Power From V(A channel) or IEC Auxiliary Input standard
–No separate, regulated 120VAC power source
required
–No need for Long Extension Cords or Step-Down
transformers
• Internal, Rechargeable No-Maintenance Battery.
• Ride through 15 minute outage.
• 10 Year+ Non-Volatile Memory Data Retention.
 External Safety Ground Lug.
28
Summary: Unique Features
 No Other Single Instrument Combines All The Following
Features
•
•
•
•
•
•
•
•
•
•
•
•
9 Channels (4V/5I). Measure AC or DC Voltage.
Simultaneously Record RMS/Power/Waveforms.
Capture Events As Fast As 65 Microseconds.
Trigger Events on Current Inputs As Well As Voltage.
Capture 2 Pre-trigger Cycles & Many Post-trigger.
256 Sample/Cycle Rate + FFT Every Few Cycles.
THD/TDD/Individual Harmonics Trending
Display Direction of Harmonic Power Flow.
Selectively Download Explicit Data from Recording Session
Recorder Simultaneously Stores up to 60 User Defined Setups
Self-Power From Unregulated AC/DC Voltage being Recorded.
Fully Weatherproof with Wide Industrial Temperature Range.
29
Key Front Panel Displays
 Store Up To 60 Field
Selectable Setups.
 Modify CT’s Settings In The
Field
 Review Event Log On Site
30
PA-9
Starter Kit
 Example Starter Kit includes:
• PA-9 Plus, w/Full 12 MB internal memory
• Full RMS, Event, Power Flow, Energy,
Flicker, Harmonics, and Frequency
Recording Capabilities
• Removable Memory Option with 64MB
Compact Flash Card
• (3) 600/6000 Amp flexible current probes
(powered from instrument )
• ca-pa9-11- kit of 4 (unfused) voltage
cables with alligator clips and a set of
neutral jumper cables
• ca-rs232 - Communications cable
• SC-PA9 soft sided carry case
• MEGPA9IEC - 32 bit Windows
95/98/NT/2000/ME/XP Software
• Complete 1 Year Warranty
31
Thank You For The Opportunity to Show You
This Remarkable Instrument!
For more information, please contact us at:
http://www.megger.com
32