Steven E. Jones
The S4 Group Inc.
1
Integration Boot Camp | Live Demo / Training
© 2012 The S4 Group, Inc.
2
© 2014 The S4 Group, Inc.
Components, Services, And
Features Common To All S4 Open
Appliances
3
© 2014 The S4 Group, Inc.
4
© 2014 The S4 Group, Inc.
Solutions are built around a software framework
using a Lego®-like architecture with plug-in modules
Upstream Interfaces
Ethernet
BACnet
RS-232
OPC
®
Metasys N2
RS-485
SNMP
XML/oBIX
…
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Address Management
Administration
Universal
Points
Object Management
Metasys®
OPC
N2
Ethernet
BACnet
RS-232
MODbus
DALI
RS-485
Siemens P1
…
Ethernet Serial Server
Downstream Interfaces
5
© 2014 The S4 Group, Inc.
6
Automatically detects all
S4 Open Appliances
Configure the system
Manage all S4 Open
Appliances on the
network
Review detailed
information on any field
device
Test read and write to
any point on any device
Rename, create, and
delete points or devices
© 2014 The S4 Group, Inc.
7
© 2014 The S4 Group, Inc.
8
© 2014 The S4 Group, Inc.
S4 Open: BACnet-N2 Router
S4 Open: OPC-N2 Router
9
© 2014 The S4 Group, Inc.
S4 Open: BACnet-N2 Router
Upstream Interfaces
Ethernet
RS- 232
RS- 485
Metasys® N2
BACnet IP
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
Metasys® N2
Ethernet
RS- 232
RS- 485
Downstream Interfaces
S4 Open: OPC-N2 Router
Upstream Interfaces
Ethernet
RS- 232
RS- 485
Metasys® N2
OPC
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
Metasys® N2
Ethernet
RS- 232
Downstream Interfaces
10
RS- 485
N2 Read, Write, Override, and Release supported
All N2 sub-protocols and hardware types are fully
supported
Upstream Interface – Facing the supervisory controller
◦ The N2 Router and BACnet (or OPC) interface are transparent to
the Metasys® supervisory controller
◦ N2 address translation
11
Downstream Interface – Facing the field devices
Automatically detect N2 hardware type and loaded
application
Automatically assign point mappings via Device Type
Template
© 2014 The S4 Group, Inc.
BACnet IP
The BACnet-N2 Router has a presence on the local
BACnet Network
◦ Device ID and Network can be set and easily modified via the
management console
Each discovered N2 device is published as a BACnet
device under a virtual BACnet network
Virtual BACnet devices are assigned unique BACnet
device IDs
◦ based on the N2 address and user specified offset
12
Standard BACnet Data Objects are Supported
BACnet Priority Array is supported
© 2014 The S4 Group, Inc.
The S4 Open: Management Console transparently
creates a local OPC Proxy Server
◦ establishes a secure tunnel to the S4 Open Appliance
◦ established on the local machine during the Auto
Detection process, or manual linking process, for S4 Open
appliances
From the standpoint of an OPC client application, it
is talking to a local OPC server
◦ there are no DCOM configuration or security issues
13
© 2014 The S4 Group, Inc.
14
© 2014 The S4 Group, Inc.
Typical Metasys (Generation 2)
Installation
BACnet
(ETHERNET)
M3 / M5 Workstation
BACnet
(ETHERNET)
Ethernet Network
N30 / NCM
Supervisory
Controller
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
Note: S4 Open Appliances work with any supervisory controller that supports the N2 Protocol: Companion /
Facilitator, NCM, N30 / N31, NAE, FX Series, European Only supervisory systems
15
© 2014 The S4 Group, Inc.
16
Benefit: Leverage existing infrastructure
Replace HMI with BACnet or OPC based solution
Merge legacy busses if desired
Manage both new and existing equipment from one
interface
Always the starting point
© 2014 The S4 Group, Inc.
17
Benefit: Cost of upgrading can be distributed over
any length of time
Replace HMI with BACnet or OPC based solution
Gradually replace Legacy equipment with new
solution
Seamlessly transition to new equipment on parallel
MS/TP bus
Simply unplug N2 Router when upgrade is complete
© 2014 The S4 Group, Inc.
The legacy supervisory controller continues its
global control task forever
The S4 Open Appliance can act as an on-site agent
for Cloud-based services
◦ Value added applications can be added to older buildings.
18
The N2 Router and BACnet (or OPC) Interface are
transparent to Metasys®
Can be used as a stepping stone to eventually
migrate to new technology
© 2014 The S4 Group, Inc.
19
The legacy supervisory controller can be removed
completely
If the new head end can perform the following:
◦ Occupied / Unoccupied schedules. The N2 field devices
normally do not include a time clock so they must rely on the
head end for scheduling activities.
◦ Trending and logging activities.
◦ Global Variable support. For example, an outside air
temperature sensor on one N2 device may be shared with other
N2 devices on the same N2 bus or with N2 devices on other
Metasys® networks.
◦ Custom logic coded into the NCM or other supervisory
controllers with GPL, JC Basic, or other languages.
When the legacy supervisory controller is removed, the
S4 Open appliance will act as bus master.
© 2014 The S4 Group, Inc.
20
Upstream Open Interface (BACnet or OPC?)
# of N2 devices per N2 bus
# of N2 buses per Metasys® supervisory controller
Election of Upstream N2 option enabling
coexistence with the Metasys® supervisory
controller
# of years of Software Assurance needed
Systems are sold as complete system bundles
Licensing is independent of the # of points
© 2014 The S4 Group, Inc.
S4 Open: Software Assurance program for S4 Open
Appliances Annual Subscription includes:
◦ All minor software or firmware enhancements and bug
fixes
◦ Device Type Template updates
◦ All major software or firmware releases
◦ Telephonic and eMail support
◦ Access to the secure support area of the S4 Group web site
21
One year of Software Assurance is included with
each system purchase.
This program extends software support through the
2nd and subsequent years of product ownership.
© 2014 The S4 Group, Inc.
S4O-BACnet-N2-N016-D1-U0-S
-S indicates that this is a complete system package. If absent, this indicates a barebones appliance.
The absence or presence of an upstream N2 interface. U0 (absent) or U1 (present)
The number of Downstream N2 interfaces that are licensed. D1, D2, or D3
The size of the N2 Router i.e. the number of N2 devices it is licensed to support. N016,
N032, N064, N128, or N256
Indicates the product family: S4O-BACnet-N2 or S4O-OPC-N2
Note 1: Utilizing the Upstream N2 port allows you keep legacy Metasys® supervisory controllers in place.
Note 2: Johnson Controls reserves N2 addresses 0, 254, and 255.
22
© 2014 The S4 Group, Inc.
23
© 2014 The S4 Group, Inc.
24
S4 technology and recommended procedures are
geared towards minimizing and mitigating risk
inherent in the integration process.
Plan carefully
Assume nothing
Utilize lessons learned shared by other Integration
Partners
Detect telltale signs early and take aggressive action.
Share your own experiences
© 2014 The S4 Group, Inc.
Validate that the customer’s N2 Bus is within
specifications with
◦ a digital volt meter, or
◦ The ComBus Quick Tester, or
◦ The S Squared S2USB485 and S2USB485DiagN2
25
Note any known problems identified in the
Metasys® OWS
Run a HVAC Pro “devices” report
Schedule and complete any maintenance work
before starting integration
© 2014 The S4 Group, Inc.
26
Hand Held Device
Quickly tests the entire N2 system
Checks bus voltages indicating
Pass/Fail
Counts all devices on the bus and
identifies each by hardware type and
N2 address
Works as a Master Controller to check
the entire system or segments of the
network
© 2014 The S4 Group, Inc.
USB to RS-485 Converter
OBD (On-Board Diagnostics) analyze
voltage of the RS485/N2 bus
S2USB485DiagN2 utility
◦ Checks bus voltages indicating Pass/Fail
◦ Confirms no other “Master” devices are
active on the network
◦ Produces a simple report
27
Supports all Metasys® utilities HVAC
Pro, GX9100, etc.
© 2014 The S4 Group, Inc.
Using JCI’s Metasys ® Utilities, Identify
◦ What applications are loaded on existing N2
controllers
◦ Interlocks or Single Side Loops in N2 field devices
◦ Which points are relevant to bring in to the new
head-end
◦ Which controllers are obsolete and require
replacement (remove risk)
Supervisory Logic and Services
◦ Custom logic in the supervisory controller
◦ Scheduling, trends, or other standard services
Metasys ® Utilities are available through
distribution
◦ M-Tools package
HVAC Pro – N2 Open and VMA devices
GX9100 – DX-9100
If you do not have Metasys® expertise
◦ Find an independent consultant
◦ DO NOT GUESS!
28
© 2014 The S4 Group, Inc.
Integrated Lighting Controllers (ILC) did not follow the
N2 Open Spec and are very maintenance intensive.
◦ Replace them day one.
Expansion I/O cards in a NCU or NEU chassis depend
on logic in the NCM.
◦ Replace them with current technology.
N2 devices operating in adverse environmental
conditions might be a high risk.
◦ Replace them as soon as practical.
Remember: As soon as you touch the system you own it.
◦ In the building owner’s mind anything that happens on your
watch is your responsibility.
29
© 2014 The S4 Group, Inc.
The following ports must be open to enable full
functionality of your S4 Open Appliances.
◦ The S4 Open: Management Console properly configures these
resources for the host system it is running on but there may be
occasions where your IT support staff or network administrator
needs to know these details.
◦ UDP Port 135 – DCOM / OPC Support
◦ TCP Port 25 – Outbound SMTP support
◦ UDP Port 61134 – Auto Detect S4 Open Devices
◦ UDP Port 68 – BOOTP Support for the S4 Open: Management
Console
◦ UDP Port 68 – DHCP support for the S4 Open: Management
Console
30
Web Interface is password protected
Telnet and FTP services are disabled
© 2014 The S4 Group, Inc.
31
© 2014 The S4 Group, Inc.
32
© 2014 The S4 Group, Inc.
33
© 2014 The S4 Group, Inc.
Used by Auto Configure Wizard
◦
◦
◦
◦
Can be manually assigned
Field customizable
Stored in On-board Catalog
Off-line library available
Each N2 Device Type Template
starts with a header section
Next is the Point Map section
Unique Device Concerns
◦
◦
◦
◦
34
Application Device Type
Hardware Device Type
Custom Device Type
Probe For Points
VND
MIG
System-91 Devices
Point Multiplexer
© 2014 The S4 Group, Inc.
Install S4 Open Management Console
◦ Free management utility provided by S4 that works as a
Microsoft Management Console snap-in
Load Device Type Templates (if needed)
◦ Template library on Support CD
◦ Custom templates
Run Auto Configure Wizard
◦ You may need to manually assign device type templates
after Wizard completes
35
© 2014 The S4 Group, Inc.
Note: N2 devices will appear off-line to the supervisory controller during the auto configuration process.
36
© 2014 The S4 Group, Inc.
M3 / M5 Workstation
Replacement
Workstation
Ethernet Network
N30 / NCM
Supervisory Controller
Install the replacement OPC or
BACnet HMI / Head End
S4 Open
Appliance
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
37
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
© 2014 The S4 Group, Inc.
Develop Graphics for new HMI
If the legacy head end is being removed you may
need to:
◦
◦
◦
◦
Define Schedules
Define Trends
Replace any Global Variables
Replace any supervisory controller logic
Be aware: the legacy head end and the replacement
workstation may both try to control the same
points!
◦ The last one in wins
38
© 2014 The S4 Group, Inc.
M3 / M5 Workstation
Replacement
Workstation
Ethernet Network
N30 / NCM
Supervisory Controller
Remove Legacy Metasys
Supervisory Controller and
Workstation
(Optional)
S4 Open
Appliance
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
39
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
© 2014 The S4 Group, Inc.
40
N2 Device and Point Discovery
Device Type Catalog
Device Type Template Assignment
(Modified) point lists
© 2014 The S4 Group, Inc.
41
Manual Updating Configuration
Backup and Restore
Device Type Template Catalog
BACnet Features
BACnet names
IP Configuration
BBMD Configuration
Remote Reboot
Firmware Updates
© 2014 The S4 Group, Inc.
42
© 2014 The S4 Group, Inc.
Enables the Supervisory Controller on the upstream
interface to participate in the Priority Array
Mechanism
Supervisory controller originated transactions can
operate at any of the 16 standard BACnet priorities
If Disabled, the supervisory controller operates at a
priority higher than any BACnet client or
application
Supervisory controller can operate at a priority
lower than any BACnet client or operation
◦ can be put into read-only mode
43
© 2014 The S4 Group, Inc.
Optonal
Replacement
Workstation
M3 / M5
Workstation
Ethernet Network
N30 / NCM
Supervisory
Controller
S4 Open
Appliance
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
VMA Device
(N2B
Protocol)
44
DX-9100
(System 91
Protocol)
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
TCS Basys
(VND Device)
© 2014 The S4 Group, Inc.
45
No two devices can have the same address, so…
◦ The N2 Router translates N2 addresses to resolve duplicate addresses
◦ Device on the lower bus keeps original address
◦ No need to manually change N2 device switches
© 2014 The S4 Group, Inc.
Replacement
Workstation
BACnet or OPC
(ETHERNET)
Downstream N2 Connection Via
Advantech ADAM Ethernet Serial
Server
ADAM
Serial Server
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
46
N2 Protocol
(ETHERNET)
N2 Protocol
(ETHERNET)
BACnet or OPC
(ETHERNET)
Ethernet Network
S4 Open
Appliance
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
© 2014 The S4 Group, Inc.
47
Replacement for Metasys® Passthrough Mode
Implemented as a virtual COM port managed by the
S4 Open Management Console
Limited to COM1 and COM2 because of M-Tools
Can be installed on any Windows PC running the
Management Console
Licensed as part of the Metasys® Upstream N2
Option
Scheduled for the next firmware update
© 2014 The S4 Group, Inc.
Points defined in Device Type Templates determine
what is published to BACnet (or OPC)
Independent of Supervisory Controller database
Defines points in the addressed N2 device
◦ Supports N2 Open, N2B, and System-91 N2 variants
48
Defines Smart Data Points
Defines Engineering Units, Enumerations, and
other point attributes
Today defined as a .CSV file, moving to XML
© 2014 The S4 Group, Inc.
Virtual Points exist only
in the N2 Router
Domain is the N2 device
Defined in the Device
Type Template
JC Basic compatible
scripts drive the value
◦ Triggered by BACnet Read or
Write Operations
◦ Enables emulation of other
manufacturer devices
49
Published to BACnet
© 2014 The S4 Group, Inc.
Input: Metasys® Resource Files
Output:
50
◦ .PRN for N2 Open ASCs and VMAs
◦ .DMO for DX-9100
◦
◦
◦
◦
Hardware device Type Template
Application Device Type Template
Custom Device Type Template
Import into Device Types Catalog
Results may be manually customized
Download from
http://www.thes4group.com/ClickOnce/S4FileConverte
r/publish.htm
Automatically updates upon startup
© 2014 The S4 Group, Inc.
51
Resource file converter utility creates a custom
Device Type Template for each device
N2 Open Override and Release functionality is
emulated for the DX-9100
Points are published with accurate object types for
each point
User friendly point names are included from the
.DMO resource file.
Devices on XT expansion bus are fully supported.
© 2014 The S4 Group, Inc.
52
© 2014 The S4 Group, Inc.
53
© 2014 The S4 Group, Inc.
The N2 bus operates at 9600 baud half-duplex
◦ This can’t be changed!
◦ The S4 Open appliance protects the N2 bus from becoming overwhelmed with requests from
high speed Ethernet interfaces
◦ The S4 Open appliance has built in performance and error monitoring capabilities
Installation problems
◦ Validate the N2 bus
◦ Repair any electrical or installation problems
◦ Make sure that the installation follows RS-485 standards. Repeaters may need to be replaced or
added to boost weak signals
Polling a large number of points at high frequency
◦ EMF interference and malfunctioning N2 devices, along with other factors, contribute to timeout, data loss, and associated errors
These issues compound exponentially as the physical downstream Bus grows in
size and age
JCI Engineering Guidelines
◦ N30 – 50 N2 devices
◦ NCM – 100 N2 devices
◦ DX-9100 and VMAs count as two
54
© 2014 The S4 Group, Inc.
Split a single large N2 Bus into multiple downstream
networks
◦ Each segment is brought into a single N2 Router on separate
downstream ports
◦ The new configuration will continue to look and behave like a
single N2 Bus to any upstream supervisory controllers
◦ This is all achieved without the need to implement any new logic
in the supervisory controller or extensive rewiring.
Split a single large N2 Bus into multiple independent
segments
◦ Each segment is served with its own S4 Open Appliance
◦ From the point of view of the supervisory equipment, there are
now 2 separate N2 buses
◦ At the field level, communications are more resilient and better
error detection and correction can be performed
55
© 2014 The S4 Group, Inc.
BACnet services can be de-selected to support
special needs.
BACnet performance parameters can be adjusted
56
Example: Tuning system for Niagara installations
Niagara expects instantaneous response from
BACnet IP
Deselecting RPM / WPM support makes BACnet
IP chatty but foces Niagara to handle each
BACnet property as a separate request
Eliminates points going stale in Niagara.
Utilizing COV support, or enabling Caching
would achieve the same results
© 2014 The S4 Group, Inc.
57
© 2014 The S4 Group, Inc.
58
© 2014 The S4 Group, Inc.
59
© 2014 The S4 Group, Inc.
60
© 2014 The S4 Group, Inc.
61
BACnet statistics are
currently oriented
towards the internal
BACnet stack
performance.
Enhancements are
scheduled that will
add integration
performance statistics.
© 2014 The S4 Group, Inc.
62
The Johnson Controls
web site is a great
resource for
documentation on N2
devices and the
Metasys® technology
CAS BACnet Explorer
Read Tapes feature
WireShark
M-Tools
© 2014 The S4 Group, Inc.
63
Example Integrations Using S4 Open Appliances
© 2014 The S4 Group, Inc.
64
Key tool to leverage success stories into more
business for both S4 and our partners.
Describe the size and complexity of the project
Discuss alternative solutions considered
Highlight the reasons why the S4 Open Appliance
was the best solution for this situation
Highlight how the S4 Integration Partner’s skills
brought together all the components to make the
project a success
Emphasize why this project was important to the
building owner or operator
© 2014 The S4 Group, Inc.
Problem
◦ A facility owner has a small, one
story, office building with 12
units.
◦ The building has a total of 10 N2
devices
◦ The N30 supervisory controller
is no longer functioning, all N2
devices are in default operation
mode.
Solution
◦ Replace N30 with S4 Open:
BACnet-N2 Router 16
◦ Install new BACnet based HMI
65
© 2014 The S4 Group, Inc.
66
Problem
Solution
◦ A school district needs to keep
track of energy usage across a
diverse range of buildings
◦ A sizable percentage of the
buildings are Metasys® based
◦ The district already uses an OPCbased trending solution for central
reporting for some of its buildings
◦ Install an appropriately sized S4
Open: OPC-N2 Router in each
building
◦ Connect each S4 Open: OPC-N2
Router to the central office via
existing IT infrastructure
© 2014 The S4 Group, Inc.
Problem
◦ A building operator wants to migrate from
Metasys® to a purely BACnet-based system
◦ Budget does not allow for a complete upgrade to
take place all at once
Solution
◦ Install one appropriately sized S4 Open:
BACnet-N2 Router for each legacy supervisory
controller
◦ Install a new BACnet-based HMI, all data from
the legacy Metasys® installation is immediately
available to the new system
◦ Leave the legacy controller in place and allow it
to continue communicating via the upstream
interface on the S4 Open: BACnet-N2 Router
◦ Run a parallel BACnet field bus and replace N2
controllers with BACnet controllers as budget
allows or as need arises
67
© 2014 The S4 Group, Inc.
68
© 2014 The S4 Group, Inc.
69
© 2014 The S4 Group, Inc.
1.The N2 Router supports any N2 device that you will
find on a N2 bus including N2 Open, VMA, Vendor
Devices, Metasys Integrator, and Centaurus
Integrator; direct Read, Write, Override, and Release
transactions for any point limited only by the
programming in the N2 device.
70
© 2014 The S4 Group, Inc.
2. The Upstream Interface enables the co-existence with
the Metasys® head end. This is a key feature in cases
where minimal (or zero!) down time is mandated.
The entire legacy Metasys® system is turned into an open
environment on day one. The building owner and
operator now have a world of non-proprietary options to
choose from to expand and enhance their building while
extending the useful life of the systems they have already
invested in.
71
© 2014 The S4 Group, Inc.
3.Auto discovery and configure wizard, facilitated by
our robust library of Device Type Templates which
predefine point mapping for each Metasys® device
and application (custom templates can also be
generated from Metasys® resource files) – all
minimize the man hours required to integrate your
N2 devices to BACnet.
72
© 2014 The S4 Group, Inc.
4.Use all of the features of HVAC Pro and GX-9100,
including uploading and downloading devices. The
N2 Router can provide a replacement for the Metasys®
“Passthrough” option for the configuration and
commissioning utilities (in development).
73
© 2014 The S4 Group, Inc.
5.In buildings with older, and potentially less reliable,
N2 devices, the BACnet-N2 Router automatically
resets N2 devices when multiple retries of an
operation fail; it also logs the number of times that
this action is taken.
74
© 2014 The S4 Group, Inc.
6.The N2 Router products expose all N2 device points
to the new head end, even those that JCI doesn’t
normally expose to their operator workstation, such
as tuning parameters.
75
© 2014 The S4 Group, Inc.
7.The N2 Router products work independently of any
database, priority, or security settings in the Metasys®
supervisory controller.
76
© 2014 The S4 Group, Inc.
8.The N2 Router products establish a very cost
effective gateway to BACnet IP in the short term,
quickly adding value and extending the life of legacy
systems. Facilitates the migration away from Metasys®
N2 devices in the longer term.
77
© 2014 The S4 Group, Inc.
9. The N2 Router can force the N2 data stream from
legacy Metasys® supervisory controllers (NCM, for
instance) to participate in the BACnet priority array
mechanism, giving the integrator complete control
over which head end is commanding each point. No
other product has this “supervisory controller as a
BACnet client” capability.
78
© 2014 The S4 Group, Inc.
10.Publish each N2 device as its own BACnet device
within a virtual BACnet network.
79
© 2014 The S4 Group, Inc.
80
Integration Boot Camp
Sales Boot Camp
Scheduled quarterly
On-demand sessions possible
Covers everything in the Live Demo in much more
detail
Includes hands-on exercises in the S4 test lab
© 2014 The S4 Group, Inc.
81
© 2014 The S4 Group, Inc.
82
Protocol Plug-ins can be added to any S4 Open
Appliances or Obermeier Software products as
options.
Service Plug-ins can be added to any S4 Open
Appliances or Obermeier Software products as
options.
© 2014 The S4 Group, Inc.
83
Obermeier Software is S4’s Development Partner
Obermeier Software’s SNMP OPC Server and OPC
SNMP Enterprise Agent (eAgent) pre-dated the S4
Open Products
The Obermeier Products are migrating to the same
architecture and framework as the S4 Open
Appliances
Major difference: These are software only products
Protocol plug-ins will be compatible with both
product lines
© 2014 The S4 Group, Inc.
S4 Open: BACnet-EnOcean Gateway
S4 Open: OPC-EnOcean Gateway
S4 Open: BACnet-FLN Router
S4 Open: OPC-FLN Router
S4 Open: BACnet-Novar Router
S4 Open: OPC-Novar Router
SNMP BACnet-Server
BACnet OPC Server
Modbus SNMP eAgent
84
© 2014 The S4 Group, Inc.
Core Services
• Logic engine to
migrate Metasys®
Global Variables
(Data Distribution
Daemon)
• Support for more
serial server brands
• BACnet Scheduling
• BACnet Alarming
• Wherever our
partners and the
market take us
85
Downstream Protocols
•
•
•
•
•
•
•
•
•
•
•
BACnet MS/TP
Barber-Colman
CSI
DALI
EnOcean
Ethernet/IP
Metasys® N1
(Ethernet)
MODbus/TCP
OPC
PROFIbus
Siemens P1
Upstream Protocols
•
•
•
•
SNMP v1/v2/v3
XML / oBIX
Web Services
Metasys® N2 - 3rd
party (non-N2)
devices published as
N2 Vendor (VND)
devices
• BACnet /WS
© 2014 The S4 Group, Inc.
S4 Open: BACnet-EnOcean® Gateway
S4 Open: OPC-EnOcean® Gateway
86
© 2014 The S4 Group, Inc.
S4 Open: BACnet-EnOcean Gateway
Upstream Interfaces
Ethernet
RS- 232
RS- 485
BACnet IP
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
EnOcean
Ethernet
Wireless
RS- 232
Downstream Interfaces
S4 Open: OPC-EnOcean Gateway
Upstream Interfaces
Ethernet
RS- 232
RS- 485
OPC
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
EnOcean
Ethernet
87
RS- 232
Downstream Interfaces
Wireless
Two major components
◦ S4 Open: BACnet-EnOcean Router
◦ EnOcean Access Point
Zones of EnOcean wireless automation can now
participate in BACnet Enterprise Solutions
BACnet EnOcean Gateway
Gateway Engine
BACnet Internetwork
88
BACnet
Connector
<Administration> <Scheduling>
<Name Space Resolution> <Routing>
<Data Integrity> <Discovery>
<Caching> <Object Management>
<Service Translation or Emulation>
EnOcean®
Connector
EnOcean® Network
© 2014 The S4 Group, Inc.
89
Built on the S4 Open Appliance Framework
Delivered as a turnkey network appliance, hosted
on an Industrial PC.
EnOcean Access Points and EnOcean devices are
dynamically discovered and published to BACnet IP.
Provides systems management services for the
EnOcean Access Points.
Depending on the size of the facility, you may need
one per building, or one or more per floor.
Provides the user interface for system configuration
and administration
© 2014 The S4 Group, Inc.
90
Connect to the building infrastructure via Ethernet.
Support Power Over Ethernet (POE) or external
power sources.
Every EnOcean device and point is fully accessible,
supporting read and write operations as defined by
the EnOcean device.
Inserted as a probe into each EnOcean Zone of Automation
(hotel room, dorm room, etc.)
© 2014 The S4 Group, Inc.
S4 Open: BACnet-EnOcean Gateway - Application Scenario
BACnet / IP
EnOcean / Ethernet
S4 Open:
BACnet-EnOcean Router
BACnet HMI
S4 Open: EnOcean
Access Point
S4 Open: EnOcean
Access Point
S4 Open: EnOcean
Access Point
Scenario :
For facilities with multiple zones of EnOcean
devices, each S4 Open: EnOcean Access Point
communicates with the S4 Open: BACnet-EnOcean
Router over a standard Ethernet connection. The
router then translates and publishes this data for
use with any BACnet BAS.
EnOcean Wireless Zone
EnOcean Wireless Zone
EnOcean Wireless Zone
No Wires. No Batteries. (No Limits)2.
91
© 2014 The S4 Group, Inc.
EnOcean
DEVICES
MODEL
DOWNSTREAM EnOcean PORTS
BACnet-EnOcean Router-32
32
N/A
1
BACnet-EnOcean Router-64
64
N/A
1
BACnet-EnOcean Router96
96
N/A
1
OPC-EnOcean Router-32
32
N/A
1
OPC-EnOcean Router-64
64
N/A
1
OPC-EnOcean Router-96
96
N/A
1
92
UPSTREAM EnOcean
PORT
In addition to the EnOcean® Router you will need an
appropriate number of EnOcean® Access Points.
© 2014 The S4 Group, Inc.
S4 Open: BACnet-FLN Router
S4 Open: OPC-FLN Router
93
© 2014 The S4 Group, Inc.
S4 Open: BACnet-FLN Router
Upstream Interfaces
Ethernet
RS- 232
RS- 485
Siemens® P1
OPC
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
Siemens® P1
Ethernet
RS- 232
RS- 485
Downstream Interfaces
S4 Open: OPC-FLN Router
Upstream Interfaces
Ethernet
RS- 232
RS- 485
Siemens® P1
OPC
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
Siemens® P1
Ethernet
94
RS- 232
Downstream Interfaces
RS- 485
95
Built on the S4 Open Appliance Framework
Delivered as a turnkey network appliance, hosted on an
Industrial PC.
Standard vendor tools used to configure FLN devices on
each FLN bus.
All Apogee® FLN devices supported, including 3rd party
devices supporting the P1 protocol.
BACnet device and point level discovery.
Every FLN point is fully accessible, supporting read,
write, override, and release operations as defined by the
FLN device.
Easily upgradeable via protocol and application plug-ins
for expanded functionality.
© 2014 The S4 Group, Inc.
Building Level Network
(All Components become
Optional)
Apogee Insight
Workstation
Replacement Workstation
and BACnet Controllers
Ethernet Network
Modular
Building
Controller
(MBC)
BACnet IP
Protocol
Modular
Equipment
Controller
(MEC)
Field Level
Network
Controller
(FLNC)
FLN Upstream
P1 Protocol
(RS-485)
Building Level Network
(P2 Protocol)
TEC
Controller
(P1 Protocol)
96
TEC
Controller
(P1 Protocol)
TEC
Controller
(P1 Protocol)
S4 Open:
BACnet-FLN Router
FLN Downstream
P1 Protocol
(RS-485)
TEC
Controller
(P1 Protocol)
Other FLN
Controller
(P1 Protocol)
© 2014 The S4 Group, Inc.
MODEL
UPSTREAM FLN PORT
DOWNSTREAM FLN PORTS
BACnet-FLN Router-32
32
Optional
1
BACnet-FLN Router-64
64
Optional
2
BACnet-FLN Router-96
96
Optional
3
OPC-FLN Router-32
32
Optional
1
OPC-FLN Router-64
64
Optional
2
OPC-FLN Router-96
96
Optional
3
97
FLN DEVICES
Utilizing the Upstream FLN port allows you keep legacy Siemens
Apogee building level controllers and Insight workstation in place.
© 2014 The S4 Group, Inc.
S4 Open: BACnet-Novar Router
S4 Open: OPC-Novar Router
98
© 2014 The S4 Group, Inc.
S4 Open: BACnet-Novar Router
Upstream Interfaces
Ethernet
RS- 232
RS- 485
Novar Logic One
BACnet IP
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
Novar Logic One
Ethernet
RS- 232
RS- 485
Downstream Interfaces
S4 Open: OPC-Novar Router
Upstream Interfaces
Ethernet
RS- 232
RS- 485
Novar Logic One
OPC
Auto Configure
Virtual
Devices
Routing
Scheduler
JIT Compilers
Core Services
Add ress Management
Administration
Universal
Points
Object Management
Novar Logic One
Ethernet
99
RS- 232
Downstream Interfaces
RS- 485
10
0
Built on the S4 Open Appliance Framework
Delivered as a turnkey network appliance, hosted on an Industrial
PC.
Standard vendor tools used to configure Secondary Control Unit
devices on each NovarNet bus.
All Novar SCU devices supported, including 3rd party devices
supporting the NovarNet protocol.
BACnet device and point level discovery.
Every SCU point is fully accessible, supporting read, write,
override, and release operations as defined by the field device.
Variable speeds supported for SCUs on NovarNet bus
SCU Program Download supported when Executive controller is
removed
Easily upgradeable via protocol and application plug-ins for
expanded functionality.
© 2014 The S4 Group, Inc.
Executive Level
Network
(All Components
become Optional)
Typical Novar Integration
Dial Up
Network
Savvy Master
Controller
Building Level
Controller
New Head End
BACnet IP
(ETHERNET)
BACnet IP
(ETHERNET)
iScope Workstation
Ethernet Network
NovarNet
Upstream Protocol
(RS-485)
BACnet IP
(ETHERNET)
NovarNet
Downstream Protocol
(RS-485)
S4 Open:
BACnet-NovarNet
Router
Novar SCU
Hawki
10
1
Novar SCU
IOM/2
Novar SCU
VAV
Novar SCU
HPC+
Novar SCU
….
© 2014 The S4 Group, Inc.
MODEL
UPSTREAM NovarNet
PORT
DOWNSTREAM NovarNet PORTS
BACnet-Novar Router-16
16
Optional
1
BACnet-Novar Router-32
32
Optional
1
BACnet-Novar Router-128
128
Optional
1
OPC-Novar Router-16
16
Optional
1
OPC-Novar Router-32
32
Optional
1
OPC-Novar Router-128
128
Optional
1
10
2
SCU DEVICES
Utilizing the Upstream NovarNet port allows you keep legacy
Novar Executive controllers and iScope workstation in place.
© 2014 The S4 Group, Inc.