Avery Weigh-Tronix Model E1310 PowerPoint

Download Report

Transcript Avery Weigh-Tronix Model E1310 PowerPoint

Core Intelligence
Model
1310
Indicator/Controller
Communicate in the language of your business
Provide
accurate weights
Stainless steel
NEMA 4X
Diagnose and
isolate potential
problems
Command
weight-based
processes
Support 32
weight sensors
up to 8 scales
Class III/IIIL 10,000 divisions
NTEP CC# 01-033 A1
Convey meaningful operational
status information
Model 1310 Standard Features
Tactile metal domed keys
Audio acknowledged key presses
Fast alpha entry keys A-Z
Convenient numeric entry keys 0-9
Model 1310 Standard Features
Large dot graphic display
 5" wide by 1.33" high
 240 dots by 64 dots
 Character height 1.16 " to 0.145 "
 White on blue
cold cathode fluorescent backlit
Graphics, text, weight capable
4 million 170 thousand and 33 unique displays
Single Scale or Multi-Scale
Weight, labels, text and scale number
Batching and Labeling
Weight, labels, text, graphic percentage via
Arch or Pie Chart, and text message
Process Control or Sorting
Weight, labels, text, graphic percentage via
Tach or Bar Graph, and related text message
Multiple Scale Display
Eight simultaneous scales
8 Vertical graph percentages
8 scale weights with labels
Model 1310 Standard Features
128 K memory
Display rates selectable
 once every ten seconds
 ten times a second
Harmonizer filtering
Supported units of measure
 Pounds, kilograms, grams,
ounces, pounds and ounces,
four programmable custom units
Model 1310 Diagnostic Features
Monitor scale activities both analog
and SensorComm systems
Standard 911 Menu items
 Traffic counter
Configurable Trigger and Re-Arm
 Overload events
 Under load events
Last ten items maintained in memory
Model 1310 Standard Feature
Ready To Communicate
Four bi-directional serial ports
Port 1* RS-232, RS485/422
Port 2 RS-232, 20 mA current loop **
Port 3* RS-232, RS485/422
Port 4* RS-232, RS485/422
* SensorComm & Quartzell compatible
** Great for long distance remote display interface
Model 1310 Features
Four built-in sockets for OPTO 22 devices
 Utilize for remote keys (Zero, Tare, Print, etc)
 Control output actions
 Use for input events
In motion Weigh Leg or Conveyor Scale
Installed application program determines OPTO 22
functionality
OPTO 22 sold separately
Model 1310 Operation
Standard Unit P/N 52936-0034
Basic weighing
Product identification - 2,000 registers
Up to sixteen alpha numeric characters
Tare data base - 2,000 registers
Soft key functions
Model 1310 Operation
Standard Unit P/N 52936-0034
ID Registers
sample print report
Tare Data Base
sample print report
Model 1310 Operation
Truck In/Out Unit P/N 52936-1032
Product identification
 Up to sixteen alpha numeric characters
Tare data base - 4,000 registers
Open transactions - 500 registers
Stored completed transactions - 1,000
Application soft keys
Model 1310 Operation
Truck In/Out Unit P/N 52936-1032
Completed
transaction
ticket sample
Model 1310 Feature
PS/2 keyboard port is standard on all units
 Connect an optional keyboard for
convenient table top key actions
Model 1310 Optional Enhancement
Additional scale inputs
 1, 2, 3, 4, 5, 6, or 7
 Eight independent scales possible
Up to thirty two 350 ohm weight sensors
Simultaneously display up to eight weight values
Include graphics and or text
Model 1310 Optional Enhancement
Analog Output
Up to eight outputs
 0-5, 0-10, 5, or 10 Vdc
 0-20, 0-24, 4-20 mA
Provide scale data in Vdc or Milli amp
format required by peripheral
Model 1310 Optional Enhancement
Pulse Inputs
Flow Meters
In-Motion Systems
 Measure liquid
materials
 Verify belt or motor
operation
TTL input 0-5 vdc
Model 1310 Optional Enhancement
Memory Expansion
Store more data then standard 128K
Two choices
 1 megabyte
 4 megabyte
Utilize two options for maximum of 5 or 8 MB
Battery protected data
Model 1310 Optional Enhancement
Telephone modem
Component installed within enclosure
Telephone interface to PC
 PC HyperTerminal mode to view information
Mobile pager alter allows quick response
Model 1310 Optional Enhancement
Expanded control interface SSCU-8
Control circuits for OPTO 22 devices
 Add up to eight remote control cards
64 I/O modules
Batch, stop, start, monitor
Model 1310 Supports SensorComm
SensorComm digital junction box
Supports up to four SensorComm
 Sixteen Weigh Bars
 Single or multi-scale
SensorComm power supplied by 1310
Data transmitted via RS485
Individual sensor monitoring
1310 & SensorComm
Detect bad weight sensor automatically with no
interruptions. Then simulate good sensor output
for the detected bad weight sensor.
Replace bad weight sensor when schedule
permits down time for replacement.
GHOST
allows
you to keep
running.
Murphy’s Law:
Anything that can
go wrong, will!
You have to batch
product, a sensor
stops working, the
replacement is
days away!
Ghost
Model 1310 Ghost on Truck Scales
Ghost mode is a configurable choice
Ghost will simulate
one weight sensor
in one section
Ghost mode is
not legal for trade
Accuracy will
decrease
Model 1310 Ghost with
Adapted Scale Structures
 Ghost mode is a
configurable choice
 Ghost will simulate up to
three of four weight
sensors in one system
 Ghost mode is not legal
for trade
 Keep the process going
Model 1310 & SensorComm Provide
Weight sensor requires replacement but it is
not possible to recalibrate with test weights.
Via front panel configuration, either key in the
span factor or mV/V rating of a new sensor.
Away you go with a high degree of system
accuracy.
Model 1310 & SensorComm Provide
Predictive Maintenance:
Use the dead load shift warning to
predict a potential weight sensor failure.
Preventive Maintenance:
Use the dead load error warning
for notification of a likely weight sensor
replacement requirement.
Model 1310 Optional Enhancement
Industrial Network Interfaces
Communicate in the language
of the business, whether
controlling or transferring data
Model 1310 Industrial Network Options
Modbus/TCP
TCP/IP (Raw Sockets)
EtherNet/IP
SMTP (Simple Mail Transfer Protocol)
HTTP (HyperText Transfer Protocol)
FTP (File Transfer Protocol)
InterBus
+
Network Definition
Devices that are linked by cable, can
communicate directly with other devices
and can share resources.
Protocol - A set of rules which ensure
orderly passing of useful information
between two or more devices.
Model 1310 Network Example
 Model 1310/PLC/LAN system:
PLC: Monitors the sensors/controls drives
LAN: Downloads tolerances and logs information
Model 1310: Weighs product and sends data
to everyone
LAN
DeviceNet
Sensor
Model-1310
Field
device
HMI
Drive
PLC
Model 1310 Email Communications
Receive from indicator at designated
email address scale warnings:
 Scale overloaded
 SensorComm items -
zero drift, individual sensor errors
 Custom message “Time to calibrate”
Set up Model 1310 as email address and
view stored data
 Traffic count
 Links to data files
Ethernet 10/100 option required
Model 1310
One Device — So Many Solutions
1310
1310
Weigh-Legs
Verify Raw Materials
Weight Sensor Kits & SensorComm
Batch Process Control of Bulk Materials
Filling
Process
Network
10/100 Ethernet
Control Room
1310
1310
1310
Quality Control
Model 1310 Monitor and Control
Model 1310 Cookie Batching
Railroad Scales
Truck Scale Traffic Reports
Batching Systems
for Inventory Control
Model 1310 Control &
Transport Application
Remote Access to Plant Data
through the Internet
Model 1310 Provides All Factory Needs
1310
1310
Weight Sensor Kits & SensorComm
Batch Process Control of Bulk Materials
Weigh Legs
Verify Raw Materials
Filling
Process
Network
10/100 Ethernet
Control Room
1310
1310
1310
Quality Control
Model 1310 Factory Network Example
AS-400
Area-Controller
10/100 Ethernet Backbone
Model-1310
Work
Station
Plant Engineer
PC
PC
Sensor
PC
PROFIBUS-FMS/PROFIBUS-DP
PLC
Model-1310
CNC
PLC
HMI
DeviceNet
Field
device
Model-1310
Drive
HMI
Field
device
Sensor
Model 1310 SimPoser
Utilize Model 1310 SimPoser and mold
the indicator into the ultimate solution!