CIRCOR Gen II and Gen III Update

Download Report

Transcript CIRCOR Gen II and Gen III Update

1
Who (what) is SAM?
www.circortech.com
PHYSICAL SEPARATION
WORLD’S FIRST SAM
CLASS 1 DIV2 (ZONE 2)
C1D2 24V
POWER
+ -
APPLICATION
SPECIFIC
CONNECTOR
OP10
MODULAR
BUS
GATEWAY
2 PIN
M12 IS
CANBUS
HIGH-SPEED
OPTO COUPLERS
FOR GALVANIC
ISOLATION
BETWEEN C1D1
AND C1D2 ZONES
OP10
CAN
REPEATER
FUNCTIONS
CIRCOR
CAN
OP10
OP10
CIRCOR
DSP W/
RTOS
M12 PARALLEL
BRANCH TEES
ALL
INTRINSICALLY
SAFE
FUNCTIONS &
CIRCUTS
CIRCOR
CAN
4 ANALOG INPUTS
GOAL:
TO BRIDGE THE GAP BETWEEN
INDUSTRY ACCEPTED FIELDBUS
TECHNOLOGY AND INTRINSICALLY SAFE
CANbus. SUPPORT CONNECTIVITY TO
ANY PLC OR DCS SYSTEM.
5 PIN
M12 IS
CANBU
S OUT
120
TERMINATOR
IS Barrier
PHYSICAL SEPARATION
HIGH-SPEED
OPTO COUPLERS
FOR FIELDBUS
GALVANIC
ISOLATION
CLASS 1 DIV1 (ZONE 1)
9.5V IS
POWER IN
www.circortech.com
IS 4-20 MA
SENSORS
IS 4-20 MA
SENSORS
IS 4-20 MA
SENSORS
IS 4-20 MA
SENSORS
UP TO 4 ANALOG SENSORS
CAN
BUS
DEVICE
CAN
BUS
DEVICE
UP TO 128 DEVICES IN THEORY
(LIMITED BY POWER
CONSUMPTION, 1A MAX PER SAM)
2
Embedded “SAM”
OTHER
ANALYZERS
IN
PLANT
SCADA
OR
DCS
OPTIONAL
CONNECTIVITY
TO LAPTOP OR
PDA WITH GUI
PROCESS
ANALYZER AND
CORE CPU
ETHERNET OR FIELDBUS
LOCAL
HMI
CAN ACCESS STATUS/
HEALTH OF ANY ANALYZER
OR RELATED SUBSYSTEM,
INCLUDING SAMPLING
SYSTEM
CAN, FIELDBUS, SERIAL
I/O “MODULES” WITH µP,
DIGITAL PNEUMATIC CONTROL,
DIGITAL EPC PROPORTIONAL CONTROL FOR PILOT
DRIVEN DEVICES
CIM76
module
CLASS 1, DIVISION 2, ZONE
IS BARRIERS FOR ANALOG AND DIGITAL I/O
DIGITAL
I/O FOR
DIGITAL
DEVICES
ANALOG
I/O FOR
ANALOG
DEVICES
TEMP
CONTROL
AIR CONTROL FOR
PNEUMATICS AND
PROPORTIONAL
FLOW
TEMP CONTROLLED CABINET
CLASS 1,
DIVISION 1
ZONE
MULTI DROP
FOR ADDITIONAL
SAMPLING
SYSTEMS
THE CONCEPT BEHIND THE INTEGRATED
ANALYZER/SAMPLING SYSTEM IS TO USE WHAT
IS AVAILABLE TODAY IN TERMS OF FLUID
CONTROL/SENSING TECHNOLOGY AND THE
CURRENT I/O WITHIN THE ANALYZER
IF THE DEVICES ARE DIGITAL OR ANALOG
MULTIVARIABLE (SUCH AS HART), THEN USE THE
MULTIVARIABLE INFORMATION, IF THEY ARE
SIMPLY ANALOG, USE THE ANALOG
INFORMATION
ALL OF THIS INFORMATION AND CONTROL CAN
BE UTILIZED VIA CONVENTIONAL DCS OR HMI
CONTROL
www.circortech.com
3
Stand Alone “SAM”
LEVEL 4 (OFFICE
NETWORK)
`
FIREWALL
DCS
ETHERNET OR FIELDBUS
CONTROL
ROOM
LEVEL 3
(PROCESS
CONTROL)
TERMINAL
SERVER
LINK
FIREWALL
ETHERNET OR FIELDBUS
PROCESS
GC
PROCESS
GC
PROCESS
GC
LEVEL 2
NETWORK
(ANALYZER
DATA HIGHWAY)
FIREWALL
ZONE 2, C1D2
ETHERNET
PLC
LEVEL 1
NETWORK
(GENERIC I/O)
ETHERNET, MODBUS, PROFIBUS
-
CIRCOR
CIM76
+
ANALOG
I/O
POWER
SUPPLIES
OTHER NON-GC
SAMPLE SYSTEMS
IS DIGITAL
BUS
+ -
DIGITAL
BUS
DEVICE
CANbus
DIGITAL BUS
DEVICE
CANbus
4-20mA
OUTPUT
ZONE 1
C1D1, HIGH
TEMP
`
ANALYTICAL TECH
LEVEL 1 TERMINAL
Where does the SAM need
to sit in the network
hierarchy?
www.circortech.com
4
5
SAM Specifics
Communication module on the CIM76 is pre-certified for the
appropriate bus selection
CIM76 with Industrial Ethernet (Ethernet IP, Modbus TCP) has the
following











Java web server
FTP server
Email server for alarming
IS CIRCOR iCAN or CANopen interface
4 channels of analog input and 24VDC excitation for use with std IS shunt-diode
barriers and IS certified analog sensors
Need C1D2 certified power for 24VDC and C1D1 certified 9V power for IS
CANbus
Allows for required galvanic isolation between haz location zones and
additional isolation from PLC, Data logger, or DCS
Manages bus timing arbitration (i.e. CAN repeater functions) between
low speed CAN in IS Zone and high speed CAN, Ethernet, Profibus DP
Has capabilities to send down alarms, commands, set points down to
CAN devices and send alarms and data up to a “bus master” thru
mailbox
www.circortech.com
6
SAM Specifics
Currently used as CAN Repeater and Bus Gateway



CIM76 Module has enough low-power processing
capability for much more value added functions
Investigating the need for additional RTOS (Real time
operating system)







Bridge the gap between PLC and Sample system
Bridge the gap between C1D1 zone and C1D2 zones
Embedded OPC server utilizing CANopen EDS sheets from sample
system devices
JAVA web server can serve up system as built configuration with
dynamic web data from sample system devices, including some basic
analog 4-20mA
Inventory of all CAN devices
Password protection
Problem: Very few plant IT infrastructures would allow a
link to a field device via ethernet
www.circortech.com
7
Points for Discussion
Discussion points:









Would CIM76 module ever need to communicate to DCS
directly?
If so, could it connect via Ethernet or serial bus, or discreet
digital I/O
Where does the CIM76 module sit on the network?
Does the CIM76 need to be accompanied by a PLC? If so, how
would it communicate with the PLC?
Does the device require its own programming interface, GUI, or
programming port? Ethernet modules would have their own IP
address and also have a web interface that would allow
visualization and a possible configuration interface.
Inventory of everything on the bus?
What happens with error detection, power loss, component
change out situations?
OPC server?
www.circortech.com