Blood Administration

Download Report

Transcript Blood Administration

Hemodynamic Monitoring
By
Nancy Jenkins RN,MSN
What is Hemodynamic
Monitoring?
It is measuring the pressures in the
heart
Hemodynamic Monitoring
 Baseline data obtained (low cardiac output)
– General appearance
– Level of consciousness
– Skin color/temperature
– Vital signs
– Peripheral pulses
– Urine output
Hemodynamic Monitoring
 Baseline data correlated with data obtained
from technology
(e.g., ECG; arterial, CVP, PA, and PAWP
pressures
**Single hemodynamic values are rarely
significant. Look at trends!!
Purpose of Hemodynamic
Monitoring
Evaluate cardiovascular system
Pressure,
flow, resistance
Establish baseline values and
evaluate trends
Determine
presence and degree of
dysfunction
Implement and guide
interventions early to prevent
problems
Hemodynamic Monitoring
Components
Heart Rate
Blood Pressure and MAP
CVP
Pulmonary Artery Pressures
Systemic Vascular Pressure (SVR)
Pulmonary Vascular Pressure (PVR)
Cardiac Output/ Cardiac Index
Stroke Volume
Comparing Hemodynamics to
IV pump
 Fluid =preload
 Pump= CO or
contractility (needs
electricity)
 Tubing =afterload
Types of Invasive Pressure
Monitoring
 Continuous arterial pressure monitoring
– Acute hypertension/hypotension
– Respiratory failure
– Shock
– Neurologic shock
Types of Invasive Pressure
Monitoring
 Continuous arterial pressure monitoring
(cont’d)
– Coronary interventional procedures
– Continuous infusion of vasoactive drugs
– Frequent ABG sampling
Components of an Arterial
Pressure Monitoring System
Fig. 66-3
Arterial Line
Arterial Pressure Monitoring
 High- and low-pressure alarms based on
patient’s status
 Risks
– Hemorrhage, infection, thrombus formation,
neurovascular impairment, loss of limb
(Assess 5 P’s)
Arterial Pressure Tracing
Fig. 66-6
Dicrotic notch signifies the closure of the
aortic valve.
Pulmonary Artery Pressure
Monitoring
 Guides management of patients with
complicated cardiac, pulmonary, and
intravascular volume problems
– PA diastolic (PAD) pressure and PAWP:
Indicators of cardiac function and fluid
volume status
– Monitoring PA pressures allows for
therapeutic manipulation of preload
Manipulating the PA pressures
affects the preload
1. True
2. False
Pulmonary Artery Pressure
Monitoring
 PA flow-directed catheter
– Distal lumen port in PA
• Samples mixed venous blood
 Thermistor lumen port near
distal tip
– Monitors core temperature
– Thermodilution method measuring CO
Pulmonary Artery Pressure
Monitoring
 Right atrium port
Measurement of CVP
Injection of fluid for CO measurement
Blood sampling
Administer medications
The proximal port or right atrial
port is used to:
1. Measure the CVP
2. Administer meds
3. Measure the wedge
pressure
4. Draw blood
Pulmonary Artery Catheter
Fig. 66-7
PA Waveforms during Insertion
Fig. 66-9
Hemodynamics:
Normal value
Mean Arterial Pressure (MAP) 70 -90 mm Hg
Cardiac Index (CI)- 2.2-4.0 L/min/m2
Cardiac Output (CO)- 4-8 L/min
Central Venous Pressure (CVP) (also known as
Right Atrial Pressure (RA)) 2-8 mmHg
Pulmonary Artery Pressure (PA)
Systolic 20-30 mmHg (PAS)
Diastolic 4-12 mmHg (PAD)
Mean 15-25 mmHg
Pulmonary Capillary Wedge Pressure (PWCP)
6-12 mmHg
Systemic Vascular Resistance(SVR) 800-1200
Cardiac Output
http://www.lidco.com/docs/Brochure.pdf
Measuring Cardiac Output
 Intermittent bolus thermodilution method
 Continuous cardiac output method
Measuring Cardiac Output
 SVR, SVRI, SV, and SVI can calculated
when CO is measured
– ↑ SVR
• Vasoconstriction from shock
• Hypertension
• ↑ Release or administration of epinephrine or other
vasoactive inotropes
• Left ventricular failure
Best indicator of tissue perfusion. Needs to be at
least 60 to perfuse organs
If a patient’s B/P is 140/80 the
MAP would be:
1.
2.
3.
4.
120
80
100
60
Complications with PA
Catheters
 Infection and sepsis
– Asepsis for insertion and maintenance of
catheter and tubing mandatory
– Change flush bag, pressure tubing, transducer,
and stopcock every 96 hours
 Air embolus (e.g., disconnection)
Complications with PA
Catheters
 Ventricular dysrhythmias
– During PA catheter insertion or removal
– If tip migrates back from PA to right ventricle
 PA catheter cannot be wedged
– May need repositioning
Which would be complications in a
patient with a PA catheter?
1.
2.
3.
4.
Arrhythmias
Infection
Air embolism
Bleeding
Complications with PA
Catheters
 Pulmonary infarction or PA rupture
– Balloon rupture (e.g., overinflation)
– Prolonged inflation
– Spontaneous wedging
– Thrombus/embolus formation
Noninvasive Hemodynamic
Monitoring
 Impedance cardiography (ICG)
– Continuous or intermittent, noninvasive
method of obtaining CO and assessing
thoracic fluid status
Noninvasive Hemodynamic
Monitoring
 Major indications
– Early signs and symptoms of pulmonary or
cardiac dysfunction
– Differentiation of cardiac or pulmonary cause
of shortness of breath
– Evaluation of etiology and management of
hypotension
Noninvasive Hemodynamic
Monitoring
 Major indications (cont’d)
– Monitoring after discontinuing a PA catheter
or justification for insertion of a PA catheter
– Evaluation of pharmacotherapy
– Diagnosis of rejection following cardiac
transplantation
hemodynamic cases