Iontophoresis - McGraw Hill Education
Download
Report
Transcript Iontophoresis - McGraw Hill Education
Iontophoresis
Iontophoreis
Introduction of Ions Into The Body Using
Direct Electrical Current
Transports Ions Across A Membrane Or Into
a Tissue
It is a Painless, Sterile, Noninvasive
Technique
Demonstrated To Have A Positive Effect On
The Healing Process
Iontophoresis vs Phonophoresis
Both Techniques Deliver Chemicals To
Biologic Tissues
Phonophoresis Uses Acoustic Energy
(Ultrasound) To Drive Molecules Into
Tissues
Iontophoresis Uses Electrical Current To
Transport Ions Into Tissues
Pharmacokinetics of Ion Transfer
Transdermal iontophoresis delivers
medication at a constant rate so that the
effective plasma concentration remains
within a therapeutic window for an extended
period of time.
Therapeutic window - the plasma
concentrations of a drug which should fall
between a minimum concentration necessary
for a therapeutic effect and the maximum
effective concentration above which adverse
effects may possibly occur.
Pharmacokinetics of Ion Transfer
Iontophoresis appears to overcome the
resistive properties of the skin to charged ion
Iontophoresis decreases absorption lag time
while increasing delivery rate when compare
with passive skin application
Iontophoresis provides both a spiked and
sustained release of a drug reducing the
possibility of developing a tolerance to drug
Pharmacokinetics of Ion Transfer
Rate at which an ion may be delivered
is determined by a number of factors
The concentration of the ion
The pH of the solution
Molecular size of the solute
Current density
Duration of the treatment
Pharmacokinetics of Ion Transfer
Mechanisms of absorption of drugs
administered
by iontophoresis similar
to administration of drugs
via other
methods
Advantages of taking medication via
transdermal iontophoresis relative to oral
medications
Concentrated in a specific area
Does not have to be absorbed within the GI tract
Safer than administering a drug through injection
Movement of Ions In Solution
Ionization- Soluable compounds dissolve
into ions suspended in solutions that are
called electrolytes
Electrophoresis- Movement of ions in
solution according to the electrically
charged currents acting on them.
Movement of Ions In Solution
Cathode = Negatively charged electrode
Highest concentration of electrons
Repels negatively charged ions
Attracts positively charged ions
Accumulation of negatively charged ions in a
small area creates an acidic reaction
Movement of Ions In Solution
Anode = Positively charged electrode
Lower concentration of electrons
Repels positively charged ions
Attracts negatively charged ions
Accumulation of positively charged ions in a
small area creates an alkaline reaction
Movement of Ions In Solution
Positively charged ions are driven into
tissues from positive pole
Negatively charged ions are driven into
tissues from negative pole
Knowing correct ion polarity is essential
Movement of Ions In Tissue
Force which acts to move ions through
the tissues is determined by
Strength of the electrical field
Electrical impedance of tissues to current
flow
Movement of Ions In Tissue
Strength of the electrical field is
determined by the current density
Difference in current density between the
active and inactive electrodes establishes
a gradient of potential difference which
produces ion migration within the electrical
field
Active
electrode- the one being used to drive
the ion into the tissue
Movement of Ions In Tissue
Current density may be altered by
Increasing or decreasing current intensity
Changing the size of the electrode
Increasing
the size of the electrode will
decrease current density under that electrode.
Movement of Ions In Tissue
Current density should be reduced at
the cathode (negative electrode)
Alkaline
reaction (+ions) is more likely to
produce tissue damage than acidic reaction(ions)
Thus negative electrode should be larger (2x)
to reduce current density.
Movement of Ions In Tissue
Higher current intensities necessary to
create
ion movement in areas where
skin and fat
layers are thick further
increasing chance of
burns around
negative electrode
Sweat ducts are primary paths by which
ions move through the skin and act to
decrease
impedance facilitating
the flow of direct
current as well as
ions
Movement of Ions In Tissue
The quantity of ions transferred into the
tissues through iontophoresis is directly
proportional to
Current density at the active electrode
Duration of the current flow
Concentration of ions in solution
Movement of Ions In Tissue
Once the ions pass through skin they
recombine with existing ions and free
radicals in the blood thus forming the
necessary new compounds for
favorable therapeutic interactions
Iontophoresis Techniques
Iontophoresis Generators
Produce continuous
direct current *
Assures unidirectional
flow of ions
–
*One study has shown
that drugs can be
delivered using AC
current
Iontophoresis
Generator
Intensity control
1
to 5 mA
Constant voltage
output that adjusts to
normal variations in
tissue impedance
thus reducing the
likelihood of burns
Automatic shutdown
if skin impedance
reduces to preset
limit
Iontophoresis
Generator
Adjustable Timer
Up
to 25 min
Iontophoresis
Generator
Lead wires
Active
electrode
Inactive electrode
Current Intensity
Low amperage currents appear to be
more effective as a driving force than
currents with higher intensities
Higher intensity currents tend to reduce
effective penetration into the tissues
Recommended current amplitudes used
for iontophoresis range between 3-5 mA
Current Intensity
Increase intensity slowly until patient
reports tingling or prickly sensation
If pain or a burning sensation occur
intensity
is too great and should be
decreased
When terminating treatment intensity
should
be slowly decreased to zero
before electrodes
are disconnected
Current Intensity
Maximum current intensity should be
determined by size of the active
electrode
Current amplitude usually set so that
current density falls between 0.1-0.5
mA/cm2 of the active electrode
surface
Treatment Duration
Treatment duration ranges between 1020
minutes with 15
minutes being an average
Patient should be comfortable with no
reported or visible signs of pain or
burning
Check skin every 3-5 minutes looking
for
signs of skin irritation
Decrease intensity during treatment to
accommodate decrease in skin
Traditional Electrodes
Older electrodes made of tin, copper,
lead, aluminum, or platinum backed by
rubber
Completely covered by a sponge, towel,
or gauze which contacts skin
Absorbent material is soaked with
ionized solution
Ion ointment should be rubbed into the
skin and covered by some absorbent
Commercial Electrodes
Sold with most iontophoresis systems
Electrodes have a small chamber covered by
a semipermiable membrane into which
ionized solution may be injected
The electrode self adheres to the skin
Electrode Preparation
To ensure maximum
contact of electrodes
skin should be shaved
and cleaned prior to
attachment of the
electrodes
Do not excessively
abrade
skin
during cleaning since
damaged skin has
lowered resistance to
current and a
burn
Electrode Preparation
Attach self-adhering active
electrode to skin
Electrode Preparation
Attach self-adhering active
electrode to skin
Inject ionized solution into
the chamber
Electrode Preparation
Attach self-adhering active
electrode to skin
Inject ionized solution into
the chamber
Attach self-adhering
inactive electrode to the
skin and attach lead wires
from generator to each
Electrode Placement
Size and shape of electrodes
can cause variation in
current density
(smaller = higher density)
Electrodes should be
separated by at least the
diameter of active electrode
Wider separation minimizes
superficial current density
decreasing chance for burns
Selecting the Appropriate Ion
Negative ions accumulating at the positive
pole
or anode
Produce an acidic reaction through the
formation
of hydrochloric acid
Produce softening of the tissues by decreasing
protein density-useful in treating scars or
adhesions
Some negative ions can also produce an
analgesic
effect (salicylates)
Selecting the Appropriate Ion
Positive ions that accumulate at the
negative
pole
Produce an alkaline reaction with the
formation of sodium hydroxide
Produce hardening of the tissues by
increasing protein density
Selecting the Appropriate Ion
Inflammation
Calcium (+)
Magnesium(+)
Analgesia
Lidocaine (+)
Magnesium (+)
Edema
Dexamethasone (-)
Hydrocortisone (-)
Salicylate (-)
Spasm
Open Skin Lesions
Hyaluronidase(+)
Salicylate (-)
Mecholyl(+)
Zinc(+)
Scar Tissue
Chlorine(-)
Iodine(-)
Salicylate(-)
Treatment Precautions
Problems which might potentially arise
from treating a patient using
iontophoresis may for the most part be
avoided if the athletic trainer
Has a good understanding of the existing
condition which is to be treated
Uses the most appropriate ions to
accomplish the treatment goal
Uses appropriate treatment parameters
and equipment set-up
Chemical Treatment Burns
Most common problem is a chemical burn
which occurs as a result of direct current
itself and not because of the ion being
used
Continuous direct current creates migration of
ions which alters the normal pH of the skin
Chemical burns typically result from
accumulation of sodium hydroxide at cathode
Alkaline reaction causes sclerolysis of local
tissues
Decreasing current density by increasing size
Thermal Treatment Burns
Thermal burns may occur due to high
resistance to current flow created by
poor contact of the electrodes with the
skin
Electrodes are not moist enough
Wrinkles in the gauze or paper towels
impregnated with the ionic solution
Space between the skin and electrode
around the perimeter of the electrode
Body weight resting on top of electrode