The HERMES dual-radiator
RICH detector
Design and operating experience,
Options for improved performance
H. E. Jackson
On behalf of the HERMES Collaboration
Argonne National Laboratory
Office of Science
U.S. Department of Energy
A U.S. Department of Energy
Office of Science Laboratory
Operated by The University of Chicago
2
H. E. Jackson, RICH04
3
H. E. Jackson, RICH04
4
H. E. Jackson, RICH04
5
H. E. Jackson, RICH04
RICH operating parameters
2. Optimum aerogel thickness from test beam studies was 5 cm.
3. Pixel size was chosen for a yield of 12 pe’s and pmax=15 GeV/c
(and budget) to be 23.3 mm !  ¼ 6 mr
6
H. E. Jackson, RICH04
7
H. E. Jackson, RICH04
8
H. E. Jackson, RICH04
RICH online monitoring - wk of 04 Apr ’04
• On line performance monitor
with single-track e§’s
• Measure average angles for
aerogel and gas rings for  =1
• Measure average yields of
photo electrons per track
• Aver. aero =244 mr
• Aver. gas = 54 mr
• Performance stable – no
detectable change in angles or
yields since 1998
9
H. E. Jackson, RICH04
10
H. E. Jackson, RICH04
11
H. E. Jackson, RICH04
12
H. E. Jackson, RICH04
Pentaquark search at HERMES
+ identified in pKs
reconstructed inv mass
spectrum
Hadron PID with RICH
: 1-15 GeV p: 4-9 GeV
Essential function of RICH
is background suppression
Reject events from  (1116)
decay to p- with mass cut
PL B585 (2004) 213
13
H. E. Jackson, RICH04
Background suppression with RICH
Use quality factor rQP to require
higher probability of assignment
relative to alternatives
Pion PID is very clean (>98%)
Main contamination of identified
protons comes from misPID’s K’s
rQP > 1.5 gives much cleaner
proton sample at acceptable loss in
proton PID efficiency
rPQ>0
14
rPQ>1.5
H. E. Jackson, RICH04
PLB 585 (2004) 213
15
H. E. Jackson, RICH04
RICH unfolding procedures
Recently completed 1st flavor
decomposition of proton spin.
Measured spin asymmetries
for ’s and K’s in SIDIS.
Objective – high statistics for
each hadron sample.
Clean samples of ’s and K’s
obtained by unfolding with
standard conditions, ie.
rQP>0.
16
H. E. Jackson, RICH04
RICH unfolding procedures(con’t)
PRD, in press – A.Airapetian, et al.
17
H. E. Jackson, RICH04
Summary and Future
RICH continues to perform with
no detectable deterioration.
Improved aerogel options are
available – edge effects can be
substantially ameliorated.
Composite mirror arrays with
improved rigidity are available.
Improved pixel resolution can be
achieved with ½” pmt’s or multianode pmt’s
Substantially improved performance is possible with same design
18
H. E. Jackson, RICH04