slides-as-printed - Computer Science and Engineering
Download
Report
Transcript slides-as-printed - Computer Science and Engineering
CIS 360: Introduction to Computer
Systems
Course Notes
Mary Beth Zak Lohse ([email protected])
http://www.cis.ohio-state.edu/~lohse
Rick Parent ([email protected])
http://www.cis.ohio-state.edu/~parent
Copyright © 1998-2003 by Rick Parent, Todd Whittaker, Bettina Bair, Pete Ware, Wayne Heym
CIS360
1
Information Representation 1
Positional Number Systems: position of character
in string indicates a power of the base (radix).
Common bases: 2, 8, 10, 16. (What base are we
using to express the names of these bases?)
– Base ten (decimal): digits 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 form
the alphabet of the decimal system.
E.g., 31610 =
– Base eight (octal): digits 0, 1, 2, 3, 4, 5, 6, 7 form the
alphabet.
CIS360
E.g., 4748 =
2
Information Representation 2
– Base 16 (hexadecimal): digits 0-9 and A-F.
E.g., 13C16 =
– Base 2 (binary): digits (called “bits”) 0, 1 form the
alphabet.
E.g., 100110 =
– In general, radix r representations use the first r chars in
{0…9, A...Z} and have the form dn-1dn-2…d1d0.
Summing dn-1rn-1 + dn-2rn-2 + … + d0r0 will convert
to base 10. Why to base 10?
CIS360
3
Information Representation 3
Base Conversions
– Convert to base 10 by multiplication of powers
E.g., 100125 = (
)10
– Convert from base 10 by repeated division
E.g., 63210 = (
)8
– Converting base x to base y: convert base x to base 10
then convert base 10 to base y
CIS360
4
Information Representation 4
– Special case: converting among binary, octal, and
hexadecimal is easier
CIS360
Go through the binary representation, grouping in sets of 3 or
4.
E.g., 110110012 = 11 011 001 = 3318
110110012 = 1101 1001 = D916
E.g., C3B16 = (
)8
5
Information Representation 5
What is special about binary?
– The basic component of a computer system is a
transistor (transfer resistor): a two state device which
switches between logical “1” and “0” (actually
represented as voltages on the range 5V to 0V).
– Octal and hexadecimal are bases in powers of 2, and are
used as a shorthand way of writing binary. A
hexadecimal digit represents 4 bits, half of a byte.
1 byte = 8 bits. A bit is a binary digit.
– Get comfortable converting among decimal, binary,
octal, hexadecimal. Converting from decimal to
hexadecimal (or binary) is easier going through octal.
CIS360
6
Information Representation 6
Binary
Hex
Decimal Binary
Hex
Decimal
0000
0
0
1000
8
8
0001
1
1
1001
9
9
0010
2
2
1010
A
10
0011
3
3
1011
B
11
0100
4
4
1100
C
12
0101
5
5
1101
D
13
0110
6
6
1110
E
14
0111
7
7
1111
F
15
CIS360
7
Information Representation 7
Ranges of values
– Q: Given k positions in base n, how many values can
you represent?
– A: nk values over the range (0…nk-1)10
n=10, k=3: 103=1000 range is (0…999)10
n=2, k=8: 28=256 range is (0…255)10
n=16, k=4: 164=65536 range is (0…65535)10
– Q: How are negative numbers represented?
CIS360
8
Information Representation 8
Integer representation:
– Value and representation are distinct. E.g., 12 may be
represented as XII, C16, 1210, and 11002. Note: -12 may
be represented as -C16, -1210, and -11002.
– Simple and efficient use of hardware implies using a
specific number of bits, e.g., a 32-bit string, in a binary
encoding. Such an encoding is “fixed width.”
– Four methods: (fixed-width) simple binary, signed
magnitude, binary coded decimal, and 2’s complement.
– Simple binary: as seen before, all numbers are assumed
to be positive, e.g., 8-bit representation of
6610 = 0100 00102 and 19410 = 1100 00102
CIS360
9
Information Representation 9
– Signed magnitude: simple binary with leading sign bit.
0 = positive, 1 = negative. E.g., 8-bit signed mag.:
6610 = 0100 00102
-6610 = 1100 00102
What ranges of numbers may be expressed in 8 bits?
Largest:
Smallest:
Extend 1100 0010 to 12 bits:
CIS360
10
Information Representation 10
Problems: (1) Compare the signed magnitude numbers
1000 0000 and 0000 0000. (2) Must have “subtraction”
hardware in addition to “addition” hardware.
– Binary Coded Decimal (BCD): use a 4 bit pattern to
express each digit of a base 10 number
0000 = 0
0100 = 4
1000 = 8
E.g.,
CIS360
0001 = 1
0101 = 5
1001 = 9
0010 = 2
0110 = 6
1010 = +
0011 = 3
0111 = 7
1011 = -
123 : 0000 0001 0010 0011
+123 : 1010 0001 0010 0011
-123 : 1011 0001 0010 0011
11
Information Representation 11
BCD Disadvantages:
– Takes more memory. 32 bit simple binary can represent more
than 4 billion discrete values. 32 bit BCD can hold a sign and
7 digits (or 8 digits for unsigned values) for a maximum of
110 million values, a 97% reduction.
– More difficult to do arithmetic. Essentially, we must force the
Base 2 computer to do Base 10 arithmetic.
BCD Advantages:
– Used in business machines and languages, i.e., in COBOL for
precise decimal math.
– Can have arrays of BCD numbers for essentially arbitrary
precision arithmetic.
CIS360
12
Information Representation 12
– Two’s Complement
CIS360
Used by most machines and
languages to represent
integers. Fixes the -0 in the
signed magnitude, and
simplifies machine
hardware arithmetic.
Divides bit patterns into a
positive half and a negative
half (with zero considered
positive); n bits creates a
range of [-2n-1… 2n-1 -1].
CODE Simple Signed 2’s comp
0000
0
+0
0
0001
1
1
1
0010
2
2
2
0011
3
3
3
0100
4
4
4
0101
5
5
5
0110
6
6
6
0111
7
7
7
1000
8
-0
-8
1001
9
-1
-7
1010
10
-2
-6
1011
11
-3
-5
1100
12
-4
-4
1101
13
-5
-3
1110
14
-6
-2
1111
15
-7
-1
13
Information Representation 13
– Representation in 2’s complement; i.e., represent i in
n-bit 2’s complement, where -2 n-1 i +2 n-1-1
Nonnegative numbers: same as simple binary
Negative numbers:
– Obtain the n-bit simple binary equivalent of | i |
– Obtain its negation as follows:
• Invert the bits of that representation
• Add 1 to the result
CIS360
Ex.: convert -32010 to 16-bit 2’s complement
Ex.: extend the 12-bit 2’s complement number
1101 0111 1000 to 16 bits.
14
Information Representation 14
Binary Arithmetic
– Addition and subtraction only for now
– Rules: similar to standard addition and subtraction, but
only working with 0 and 1.
0+0=0
1+0=1
0+1=1
1 + 1 = 10
0-0=0
1-0=1
1-1=0
10 - 1 = 1
– Must be aware of possible overflow.
CIS360
Ex.: 8-bit signed magnitude 0101
0110 + 0110 0011 =
Ex.: 8-bit signed magnitude 0101
0110 - 0110 0011 =
15
Information Representation 15
2’s Complement binary arithmetic
– Addition and subtraction are the same operation
– Still must be aware of overflow.
CIS360
Ex.: 8 bit 2’s complement: 2310 + 4510 =
Ex.: 8 bit 2’s complement: 10010 + 4510 =
Ex.: 8 bit 2’s complement: 2310 - 4510 =
16
Information Representation 16
– 2’s Complement overflow
CIS360
Opposite signs on operands can’t overflow
If operand signs are same, but result’s sign is different, must
have overflow
Can two positives sum to positive and still have overflow?
Can two negatives?
17
Information Representation 17
Characters and Strings
– EBCDIC, Extended Binary Coded Decimal Interchange Code
Used by IBM in mainframes (360 architecture and descendants).
Earliest system
– ASCII, American Standard Code for Information Interchange.
Most common system
– Unicode, http://www.unicode.org
CIS360
New international standard
Variable length encoding scheme with either 8- or 16-bit minimum
“a unique number for every character, no matter what the platform, no
matter what the program, no matter what the language.”
18
Information Representation 18
ASCII
– see table 1.7 on pg. 18.
In Unix, run “man ascii”.
– 7 bit code
Printable characters for human interactions
Control characters for non-human communication (computercomputer, computer-peripheral, etc.)
– 8-bit code: most significant bit may be set
CIS360
Extended ASCII (IBM), includes graphical symbols and lines
ISO 8859, several international standards
Unicode’s UTF-8, variable length code with 8-bit minimum
19
ASCII
Easy
to decode
– But takes up a predictable amount of space
Upper
and lower case characters are 0x20 (3210)
apart
ASCII representation of ‘3’ is not the same as the
binary representation of 3.
– To convert ASCII to binary (an integer), ‘3’-‘0’ = 3
Line
feed (LF) character
– 000 10102 = 0x0a = 1010
– ‘\n’ = 0xa
CIS360
Character
‘ ’
‘A’
‘a’
‘R’
‘r’
‘0’
‘3’
ASCII Binary
010
100
110
101
111
011
011
0000
0001
0001
0010
0010
0000
0011
ASCII Hex
0x20
0x41
0x61
0x52
0x72
0x30
0x33
20
Information Representation 19
String: definition is programming language dependent.
– C, C++: strings are arrays of characters terminated by a null byte.
Decode:
1000001, 1010011, 1000011, 1001001, 1001001, 0100000, 1101001,
1110011, 0100000, 1100101, 1100001, 1110011, 1111001, 0000000
– Or (in hex):
41 53 43 49 49 20 69 73 20 65 61 73 79 00
How many bytes is this?
What’s the use of the ’00’ byte at the end?
CIS360
21
Information Representation 20
Simple data compression
– ASCII codes are fixed length.
– Huffman codes are variable length and based on
statistics of the data to be transmitted.
Assign the shortest encoding to the most common character.
– In English, the letter ‘e’ is the most common.
– Either establish a Huffman code for an entire class of messages,
– Or create a new Huffman code for each message, sending/storing
both the coding scheme and the message.
CIS360
“a widely used and very effective technique for compressing
data; savings of 20% to 90% are typical, depending on the
characteristics of the file being compressed.” (Cormen, p. 337)
22
ECL - Expected Code Length
Char
Fixed len
encoding
Freq
Var len
encoding
# bits
Expected
# bits
00
.5
1
1
.5
01
.25
01
2
.5
10
.15
001
3
.45
11
.10
000
3
.3
Avg len
2
CIS360
1.75
23
Information Representation 21
Huffman Tree for “a man a plan a canal panama”
– Examine data set and determine frequencies of letters (example
ignores spaces, normally significant)
‘a’
‘c’
‘l’
‘m’
‘n’
‘p’
Count
Frequency
10
1
2
2
4
2
0.476190
0.047619
0.095238
0.095238
0.190476
0.095238
– Create a forest of single node trees. Choose the two trees having
the smallest total frequencies (the two “smallest” trees), and
merge them together (lesser frequency as the left subtree, for
definiteness, to make grading easier). Continue merging until
only one tree remains.
CIS360
24
Information Representation 22
Reading a ‘1’ calls for
following the left branch.
Reading a ‘0’ calls for
following the right branch.
Decoding using the tree:
To decode ‘0001’, start at
root and follow r_child,
r_child, r_child, l_child,
revealing encoded ‘m’.
Huffman Tree for "a man a plan a canal panama"
1.0
'a'
.4762
'n'
.1905
.3333
.1428
'c'
.0476
CIS360
.5238
'l'
.0952
.1905
'm'
.0952
'p'
.0952
25
Information Representation 23
Comparison of Huffman and 3-bit code example
– 3-bit: 000 011000100 000 101010000100 000
001000100000010 101000100000011000 = 63 bits
– Huffman: 1 0001101 1 00000010101 1
001110110010 0000101100011 = 46 bits
– Savings of 17 bits, or 27% of original message
‘a’
‘c’
‘l’
‘m’
‘n’
‘p’
Totals
CIS360
3-bit code
Huffman Code
Count
H length
3 length
000
001
1
0011
10
1
10
4
30
3
010
0010
2
8
6
011
100
0001
01
2
4
8
8
6
12
101
0000
2
8
6
46
63
26
Parity: Simple error detection
Data transmission, aging media, static
interference, dust on media, etc. demand the
ability to detect errors.
Single bit errors detected by using parity
checking.
Parity, here, is the “the state of being odd or
even.”
CIS360
27
Information Representation 24
– How to detect a 1-bit error:
Ex.: send ASCII ‘S’: send 1010011, but receive 1010010?
Add a 1-bit parity to make an odd or even number of bits per
byte.
ASCII
Even parity
Odd Parity
CIS360
‘S’
101 0011
0101 0011
1101 0011
‘E’
100 0101
1100 0101
0100 0101
Parity bit is stripped by hardware after checking.
Sender/receiver both agree to odd or even parity.
2 flipped bits in the same encoding are not detected.
28
Information Representation 25
Two meanings for Hamming distance. 2nd is
generalization of 1st. 1st is: distance between two
encodings of the same length.
1. A count of the number of bits different in encoding 1 vs. encoding
2.
E.g.,
dist(1100, 1001) =
dist(0101, 1101) =
2. Generalize to an entire code by taking the minimum over all
distinct pairs (2nd meaning).
– The ASCII encoding scheme has a Hamming distance of 1.
– A simple parity encoding scheme has a Hamming distance of 2.
Hamming distance serves as a measure of the robustness
of error checking (as a measure of the redundancy of the
encoding).
CIS360
29
ISEM FAQ 1
Editing, Assembling, Linking, and Loading
– There are three components to the Instructional SPARC Emulator
(ISEM) package that we use for this class:
the assembler,
the linker, and
the emulator/debugger.
CIS360
30
ISEM FAQ 2
Editing
– There are a number of programs that you can use to create your
source files.
Emacs is probably the most popular;
vi is also available, but its command syntax is difficult to learn
and use;
using pine program, you can use the pico editor, which
combines many features of Emacs into a simple menu-driven
facility.
– Start Emacs by “xemacs sourcefile.s &”, which creates the file
called sourcefile.s.
– Use the tutorial, accessed by typing "Ctrl-H Ctrl-H t".
– For other editors, you are on your own.
CIS360
31
Example Sparc Assembly Language
Instructions
% type xmp0.s
.data
A_m:
.word ’?’
B_m : .word 0x30
C_m : .word 0
.text
!
!
!
!
!
!
!
Assembler directive: data starts here. A_m, B_m, and
C_m are symbolic constants. Furthermore, each
is an address of a certain-sized chunk of memory. Here,
each chunk is four bytes (one word) long. When the
program gets loaded, each of these chunks stores a
number in 2’s complement encoding, as follows: At
address C_m, zero; at B_m, 48; at A_m, 0x3F = 077 = 63.
!
start:
!
set A_m, %r2
!
ld
[%r2], %r2
!
set B_m, %r3
!
ld
[%r3], %r3
!
sub %r2, %r3, %r2 !
set C_m, %r4
!
st
%r2, [%r4]
!
terminate:
!
ta
0
!
beyond_end:
!
CIS360
Assembler directive, instructions start here
Label (symbolic constant) for this address
Put address A_m into register 2
Use r2 as an indirect address for a load (read)
Put address B_m into register 3
Read from B_m and replace r3 w/ value at addr B_m
Subtract r3 from r2, save in r2
Put address C_m into register 4
Store (write) r2 to memory at address C_m
Label for address where ’ta 0’ instruction stored
Stop the program
Label for address beyond the end of this program
32
ISEM FAQ 3
Assembling
– The assembler is called "isem-as", and is the GNU Assembler
(GAS), configured to cross-assemble to a SPARC object format.
– It is used to take your source code, and produce object code that
may be linked and run on the ISEM emulator.
– The syntax for invoking the assembler is:
isem-as [-a[ls]] sourcefile.s -o objectfile.o
– The input is read from sourcefile.s, and the output is written to
objectfile.o.
– The option "-a" tells the assembler to produce a listing file. The
sub-options "l" and "s" tell the assembler to include the assembly
source in the listing file and produce a symbol table, respectively.
CIS360
33
ISEM FAQ 4
The listing file
– Will identify all the syntactic errors in your program, and it will
warn you if it identifies "suspicious" behavior in your source file.
– Column 1 identifies a line number in your source file.
– Column 2 is an offset for where this instruction or data resides in
memory.
– Column 3 is the image of what is put in memory, either the
machine instructions or the representation of the data.
– The final column is the source code that produced the line.
– At the bottom of the file you will find the symbol table.
– Again, the symbols are represented as offsets that are relocated
when the program is loaded into memory.
CIS360
34
isem-as -als labn.s -o labn.o >!
labn.lst
1
2
3
4
5
6
7
7
8
9
9
10
11
12
12
13
14
15
16
0000
0004
0008
000c
0000003F
00000030
00000000
00000000
.data
.word ’?’
.word 0x30
.word 0
.text
A_m:
B_m:
C_m:
start:
0000 05000000
8410A000
0008 C4008000
000c 07000000
8610E000
0014 C600C000
0018 84208003
001c 09000000
88112000
0024 C4210000
0028 91D02000
002c 01000000
DEFINED SYMBOLS
xmp0.s:2
xmp0.s:3
xmp0.s:4
xmp0.s:6
xmp0.s:14
xmp0.s:16
NO UNDEFINED SYMBOLS
CIS360
Line in
source file
(.s)
set
A_m, %r2
ld
set
[%r2], %r2
B_m, %r3
ld
sub
set
[%r3], %r3
%r2, %r3, %r2
C_m, %r4
st
terminate:
ta
beyond_end:
Offset to
address
in
memory
%r2, [%r4]
0
.data:00000000
.data:00000004
.data:00000008
.text:00000000
.text:00000028
.text:0000002c
A_m
B_m
C_m
start
terminate
beyond_end
Labels are
symbolic
offsets
Contents
at
address
in
memory
35
ISEM FAQ 5
Linking
– Linking turns a set of raw object file(s) into an executable program.
– From the manual page, "ld combines a number of object and archive files,
relocates their data and ties up symbol references. Often the last step in
building a new compiled program to run is a call to ld."
– Several object files are combined into one executable using ld; the
separate files could reference symbols from one another.
– The output of the linker is an executable program.
– The syntax for the linker is as follows:
isem-ld objectfile.o [-o execfile]
Examples
% isem-ld foo.o -o foo Links foo.o into the executable foo.
% isem-ld foo.o
Links foo.o into the executable a.out.
CIS360
36
ISEM FAQ 6
Loading/Running
– Execute the program and test it in the emulation environment.
– The program "isem" is used to do this, and the majority of its features are
covered in your lab manual.
– Invoke isem as follows
isem [execfile]
Examples
% isem foo
Invokes the emulator, loads the program foo
% isem
Invokes the emulator, no program is loaded
– Once you are in the emulator, you can run your program by typing "run"
at the prompt.
CIS360
37
ISEM Debugging Tools 1
% isem xmp0
Instructional SPARC Emulator
Copyright 1993 - Computer Science Department
University of New Mexico
ISEM comes with ABSOLUTELY NO WARRANTY
ISEM Ver 1.00d : Mon Jul 27 16:29:45 EDT 1998
Loading File: xmp0
2000 bytes loaded into Text region at address 8:2000
2000 bytes loaded into Data region at address a:4000
PC: 08:00002020
start
nPC: 00002024
:
sethi
PSR: 0000003e
N:0 Z:0 V:0 C:0
0x10, %g2
ISEM> run
Program exited normally.
Assembly language programs are not notoriously chatty.
CIS360
38
ISEM Debugging Tools 2
reg
– Gives values of all 32
general registers
– Also PC
----0--- ----1--- ----2--- ----3--- ----4--- ----5--- ----6--- ----7--G 00000000 00000000 0000000f 00000030 00004008 00000000 00000000 00000000
O 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
L 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
I 00000000 00000000 00000000 00000000 00000000 00000000 00000000 00000000
PC: 08:0000204c
CIS360
sethi
PSR: 0000003e
N:0 Z:0 V:0 C:0
0x0, %g0
ISEM> symb
Symbol List
A_m : 00004000
B_m : 00004004
.
dump [addr]
– Either symbol or hex
address
– Gives the values stored in
memory
nPC: 00002050
beyond_end :
symb
– Shows the resolved values
of all symbolic constants
ISEM> reg
.
.
terminate : 00002048
ISEM> dump A_m
0a:00004000
00 00 00 3f 00 00 00 30 00 00 00 0f 00 00 00 00 ...?...0........
0a:00004010
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0a:00004020
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
39
ISEM Debugging Tools 3
break [addr]
– Set breakpoints in execution
– Once execution is stopped, you can look at the contents of registers
and memory.
trace
– Causes one (or more) instruction(s) to be executed
– Registers are displayed
– Handy for sneaking up on an error when you’re not sure where it
is.
For the all-time “most wanted” list of errors (and their
fixes)
– http://www.cis.ohio-state.edu/~heym/360/common/faq.html
CIS360
40
Basic Components 1
Terminology from Ch. 2:
– Flip flop: basic storage device that holds 1 bit
– D flip flop: special flip flop that outputs the last value
that was input to it (a data signal).
– Clock: two different meanings: (1) a control signal that
oscillates (low to high voltage) every x nanoseconds;
(2) the “write select” line for a flip flop.
Data
In
D Flip Flop
Clock
CIS360
Data
Out
one cycle
41
Basic Components 2
– Register: collection of flip flops with parallel load.
Clock (or “write select”) signal controlled. Stores
instructions, addresses, operands, etc.
– Bus: Collection of related data lines (wires).
Input Bus
d7
d6
d5
d4
d3
Clock
d2
d1
d0
8
Clock
8 Bit Register
8
Output Bus
CIS360
42
Basic Components 3
– Combinational circuits: implement Boolean functions.
No feedback in the circuit, output is strictly a function
of input.
Gates: and, or, not, xor
AND
OR
NOT
XOR
E.g., xy + z
x
y
z
CIS360
f
43
Basic Components 4
– Gates can be used in combination to implement a
simple (half) adder.
Addition creates a value, plus a carry-out.
Z=XY
CO = X Y
CIS360
X
Y
Z
CO
0
0
0
0
0
1
1
0
1
0
1
0
1
1
0
1
X
Y
Z
CO
44
Basic Components 5
– Sequential Circuits: introduce feedback into the circuit.
Outputs are functions of input and current state.
D
Q
C
– Multiplexers: combinational circuits that use n bits to
select an output from 2n input lines.
i0
i1
i2
i3
4 to 1 MUX
f
s0 s1
CIS360
45
Basic Components 6
Von Neumann
Architecture
– Can access either
instructions or data from
memory in each cycle.
– One path to memory
(von Neumann bottleneck)
– Stored program system. No
distinction between
programs and data
Main Memory System
Address
Pathway
Data and
Instruction
Pathway
Operational Registers
Arithmetic and Logic Unit
Program Counter
Control Unit
Input/Output System
CIS360
46
Basic Components 7
Examples of Von Neumann architecture to be
explored in this course:
SAM: tiny, good for learning architecture
MIPS: text’s example assembly language
SPARC: labs
Roughly, the order of presentation in this course is as
follows:
A couple of days on the Main Memory System
Weeks on the Central Processing Unit (CPU)
Finish the course with the I/O System
CIS360
47
Basic Components 8
Memory: Can be viewed as an array of storage
elements.
– The index of each element is called the address.
– Each element holds the same number of bits. How
many bits per element? 8, 16, 32, 64?
8 bits = 1 byte
CIS360
16 bits
32 bits
64 bits
0
0
0
0
1
1
1
1
2
2
2
2
...
...
...
...
n-1
n-1
n-1
n-1
48
Memory Element & Address Sizes
•If a machine’s memory is 5-bit
addressable, then, at each distinct
address, 5 bits are stored. The
contents at each address are
represented by 5 bits.
•If 3 bits are used to represent
memory addresses, then the
memory can have at most 23 = 8
distinct addresses.
•Such a memory can store at most
8 5 = 40 bits of data.
•If the data bus is 10 bits wide,
then up to 10 bits at a time can be
transferred between memory and
processor; this is a 10-bit word.
CIS360
Address
Contents
Decimal
Binary
0
000
00011
1
001
01111
2
010
01110
3
011
10100
4
100
00101
5
101
01110
6
110
10100
7
111
10011
49
Basic Components 9
Let’s look deeper.
– Suppose each memory element is
stored in a bank and given a relative
address.
– You could have several such banks
in your memory.
– The GLOBAL address of each
element would be:
[relative address] & [bank address].
– To get two elements at a time, start
reading from bank 0 (don’t start
from bank 1; this would be a
“memory address not aligned” error).
CIS360
Bank 0
000
001
010
011
100
101
Bank 0
000
001
010
011
100
101
000 0
001 0
010 0
011 0
100 0
101 0
Bank 1
000
001
010
011
100
101
000 1
001 1
010 1
011 1
100 1
101 1
Global addresses,
not contents.
Think of the contents as being
underneath the global addresses.
50
Basic Components 10
– Memory alignment: Assume a byte addressable
machine with 4-byte words. Where are operands of
various sizes positioned?
CIS360
bytes: on a byte boundary (any address)
half words: on half word boundary (even addresses)
words: on word boundary (addresses divisible by 4)
double words: on double word boundary (addresses divisible
by 8)
51
Basic Components 11
Byte ordering: how numeric data is stored in memory
– Ex.: 24789651110 = 0EC699BF16
– Stored at address 0
0 OE
1 C6
2 99
Big Endian
High order
(big end) is
at byte 0
Little
Endian
Low order
(little end) is
at byte 0
3 BF
0 BF
1 99
2 C6
3 0E
Contrast with bit ordering
CIS360
7
6
5
4
3
2
1
0
1
0
1
1
1
1
1
1
52
Basic Components 12
Read/Write operations: must know the address to
read or write. (read = fetch = load, write = store)
CPU puts address on address bus
A0
A1
CPU sends read signal
A(m-1)
– (R/W=1, CS=1)
– (Read/don’t Write, Chip Select)
Wait
Memory puts data on
data bus
– reset (CS=0)
CIS360
CS
R/
D0
D1
D(n-1)
53
W
Basic Components 13
– Types of memory:
ROM: Read Only Memory: non-volatile (doesn’t get erased
when powered down; it’s a combinational circuit!)
PROM: Programmable ROM: use a ROM burner to write data
to it initially. Can’t be re-written.
EPROM: Erasable PROM. Uses UV light to erase.
EEPROM: Electrically Erasable PROM.
RAM: Random access memory. Can efficiently read/write any
location (unlike sequential access memory). Used for main
memory.
– Many variations (types) of RAM, all volatile
• SDRAM, DDR SDRAM
• RDRAM
• www.tomshardware.com
CIS360
54
Basic Components 14
CPU: executes instructions -- primitive operations
that the computer can perform.
– E.g.,
CIS360
arithmetic
data movement
control
logical
A+B
A := B
if expr goto label
AND, OR, XOR…
Instructions specify both the operation and the operands.
Operands are usually locations in memory where the actual
operands may be found (addresses of actual operands).
55
Basic Components 15
– Instruction set: all instructions for a machine.
Instruction format specifies number and type of
operands.
Ex.: Could have an instruction like
ADD A, B, R
Where A, B, and R are the addresses of operands in memory.
The result is R := A+B.
Addr
Memory
Label
0
8
A
4
9
B
17
R
8
C
CIS360
56
Basic Components 16
– Actually, the “instruction” might be represented in a
source file as:
0x41444420412C20422C20520A. …
A D D
A ,
B ,
R
As such, it is an assembly language instruction.
– An assembler might translate it to, say, 0x504C, the
machine’s representation of the instruction.
As such, it is a machine language instruction.
CIS360
57
A Simple Instruction Set 1
Simple instruction set: the Accumulator machine.
– Simplify instruction set by only allowing one operand.
Accumulator implied to be the second operand.
– Accumulator is a special register. Similar to a simple
calculator.
CIS360
ADD
SUB
MPY
DIV
LOAD
STORE
addr
addr
addr
addr
addr
addr
ACC ACC + M[addr]
ACC ACC - M[addr]
ACC ACC * M[addr]
ACC ACC / M[addr]
ACC M[addr]
M[addr] ACC
58
A Simple Instruction Set 2
Ex.: C = AB + CD
LOAD
MPY
STORE
LOAD
MPY
ADD
STORE
20
21
30
22
23
30
22
!
!
!
!
!
!
!
1)Acc<-M[20]
2)Acc<-Acc*M[21]
M[30]<-Acc
3)Acc<-M[22]
4)Acc<-Acc*M[23]
5)Acc<-Acc+M[30]
M[22]<-Acc
Accumulator
20
A
21
B
22
C
23
D
...
30
1)
2)
3)
4)
5)
temp
– Machine language: Converting from assembly language
to machine language is called assembling.
CIS360
59
A Simple Instruction Set 3
Assume 8-bit architecture. Each instruction may be 8 bits. 3
bits hold the op-code and 5 bits hold the operand.
op-code
7
CIS360
operand
54
0
How much memory can we address?
How many op-codes can we have?
Convert the mnemonic op-codes into binary codes.
Operation
Code
ADD
SUB
MPY
DIV
LOAD
STORE
000
001
010
011
100
101
60
A Simple Instruction Set 4
Hand assemble our program:
LOAD 20
MPY
21
STORE 30
...
CIS360
100 10100
010 10101
101 11110
...
Instructions are stored in consecutive memory:
Addr
Memory
Mnemonic
0
1
2
3
4
5
6
…
20
21
22
23
…
30
100
010
101
100
010
000
101
…
4
5
6
7
…
20
LOAD A
MPY B
STORE temp
LOAD C
MPY D
ADD temp
STORE C
10100
10101
11110
10110
10111
11110
10110
A
B
C
D
temp
61
A Simple Instruction Set 5
INC
Addr
Op
2 to 1
MUX
Decode
3
Timing and
Control
PC
IR
2
9
12
Bus
4
5
6
7
0
10
1
MAR
MDR
2 to 1
MUX
ACC
11
ALU
Memory
8
13
CIS360
14
62
A Simple Instruction Set 6
– Control signals: control functional units to determine
order of operations, access to bus, loading of registers,
etc.
Number
0
1
2
3
4
5
6
7
CIS360
Operation
ACCbus
load ACC
PCbus
load PC
load IR
load MAR
MDRbus
load MDR
Number
8
9
10
11
12
13
14
Operation
ALUACC
INCPC
ALU operation
ALU operation
Addrbus
CS
R/W
63
A Simple Instruction Set 7
State
PC to bus
load MAR
INC to PC
load PC
0
1
2
3
MDR to bus
load IR
Addr to bus
load MAR
Y
4
5
OP=store
ACC to bus
load MDR
CIS360
N
CS, R/W
CS
Execute
6
OP=load
Y
7
8
Fetch
CS, R/W
MDR to bus
load ACC
N
MDR to bus
ALU to ACC
ALU op
load ACC
64
State 0: Control Signals 2, 5, 9, 3
Put the address of the next instruction in the Addr Register and Inc. PC.
INC
Addr
Op
Decode
2 to 1
MUX
PC to bus
load MAR
INC to PC
load PC
3
Timing and
Control
PC
Fetch
CS, R/W
IR
MDR to bus
load IR
2
9
12
Bus
4
Addr to bus
load MAR
5
6
7
0
OP=store
CS, R/W
CS
Execute
ACC
1
11
MAR
OP=load
ALU
Memory
8
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
13
CIS360
MDR
2 to 1
MUX
ACC to bus
load MDR
10
14
65
State 1: Control Signals 13, 14
Fetch the word of memory at Address, and load into Data Register.
INC
PC to bus
load MAR
INC to PC
load PC
Addr
Op
Decode
Timing and
Control
Fetch
2 to 1
MUX
CS, R/W
3
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
OP=store
5
6
0
ACC to bus
load MDR
CS, R/W
ACC
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
CS
10
Execute
14
66
7
State 2: Control Signals 6, 4
Send the word from the Data Register to the Instruction Register.
INC
PC to bus
load MAR
INC to PC
load PC
Addr
Op
Decode
2 to 1
MUX
Fetch
CS, R/W
3
Timing and
Control
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
OP=store
5
6
0
ACC to bus
load MDR
CS, R/W
ACC
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
CS
10
Execute
14
67
7
State 3: Control Signals 12, 5
Put the address from the instruction in the Address Register.
INC
PC to bus
load MAR
INC to PC
load PC
Addr
Op
Decode
2 to 1
MUX
Fetch
CS, R/W
3
Timing and
Control
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
OP=store
5
6
0
ACC to bus
load MDR
CS, R/W
ACC
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
CS
10
Execute
14
68
7
After State 3, what values are now stored
in each register?
PC
MAR
MDR
IR
ACC
CIS360
69
State 4: Control Signals 0, 7
Take the value from the ACCumulator and store it in the Data Register.
INC
Addr
PC to bus
load MAR
INC to PC
load PC
Op
2 to 1
MUX
Decode
Fetch
CS, R/W
3
Timing and
Control
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
5
OP=store
6
0
ACC to bus
load MDR
10
CS, R/W
Execute
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
ACC
CS
11
14
70
7
State 5: Control Signal 13
Write the data from the Data Register to the address stored in the MAR.
INC
Addr
PC to bus
load MAR
INC to PC
load PC
Op
2 to 1
MUX
Decode
Fetch
CS, R/W
3
Timing and
Control
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
5
OP=store
6
0
ACC to bus
load MDR
10
CS, R/W
OP=load
MDR to bus
load ACC
MAR
MDR to bus
ALU to ACC
ALU op
load ACC
1
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
ACC
CS
11
Execute
14
71
7
State 6: Control Signals 13, 14
Load the word at the Address from the Addr Reg into the Data Register.
INC
PC to bus
load MAR
INC to PC
load PC
Addr
Op
Decode
2 to 1
MUX
Fetch
CS, R/W
3
Timing and
Control
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
OP=store
5
6
0
ACC to bus
load MDR
CS, R/W
ACC
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
CS
10
Execute
14
72
7
After State 6, what values are now stored
in each register?
PC
MAR
MDR
IR
ACC
CIS360
73
State 7: Control Signals 6, 1
Load the word from Data Register into the ACCumulator.
INC
PC to bus
load MAR
INC to PC
load PC
Addr
Op
Decode
2 to 1
MUX
Fetch
CS, R/W
3
Timing and
Control
PC
MDR to bus
load IR
IR
Addr to bus
load MAR
2
9
12
Bus
4
OP=store
5
6
7
0
ACC to bus
load MDR
CS, R/W
ACC
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
CS
10
Execute
14
74
State 8: Control Signals 6, 8, 10/11, 1
Use word from the Data Register for Arith Op and put result in ACC.
INC
PC to bus
load MAR
INC to PC
load PC
Addr
Op
Decode
Fetch
2 to 1
MUX
CS, R/W
MDR to bus
load IR
3
Timing and
Control
PC
IR
Addr to bus
load MAR
2
9
12
Bus
4
OP=store
5
6
0
ACC to bus
load MDR
CS, R/W
OP=load
MDR to bus
load ACC
10
ACC
MDR to bus
ALU to ACC
ALU op
load ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
CS
Execute
14
75
7
New Instruction
•What is necessary to implement a new instruction?
•New states?
•New control signals?
•New fetch/execute cycle?
•An Example:
•SWAP
Exchange value in Accumulator with value at
Address
•SWAP addr
CIS360
! Acc <- #M[addr], M[addr] <- #Acc
76
New Instruction
What changes to fetch/execute cycle?
– The fetch part of the cycle usually remains the same.
– Recall the values stored in registers after each state
E.g., After State 6,
what values are in each register?
–
–
–
–
–
PC
MAR
MDR
IR
ACC
Handy to have #M[addr] in MDR
– Start after state 6 then… .
CIS360
PC to bus
load MAR
INC to PC
load PC
Fetch
CS, R/W
MDR to bus
load IR
Addr to bus
load MAR
OP=store
ACC to bus
load MDR
CS, R/W
CS
Execute
OP=load
MDR to bus
load ACC
MDR to bus
ALU to ACC
ALU op
load ACC
77
New State 9: Control Signals 6, 5
Save the Data value from the MDR in the Address Register.
INC
MDR -> bus
Load MAR
Addr
Op
2 to 1
MUX
Decode
3
Timing and
Control
PC
IR
2
9
12
Bus
4
5
6
7
0
10
1
MAR
MDR
2 to 1
MUX
ACC
11
ALU
Memory
8
13
CIS360
14
78
New State 10: Control Signals 0, 7
Send the ACCumulator value to the Data Register.
INC
ACC -> bus
load MDR
Addr
Op
2 to 1
MUX
Decode
3
Timing and
Control
PC
IR
2
9
12
Bus
4
5
6
7
0
10
1
MAR
MDR
2 to 1
MUX
ACC
11
ALU
Memory
8
13
CIS360
14
79
New State 11: Control Signals ?, 1
Put the saved value from the MAR into the ACCumulator.
INC
Addr
MAR->bus
load ACC
2 to 1
MUX
3
Timing and
Control
PC
IR
2
9
12
Bus
4
5
6
0
10
ACC
1
11
MAR
ALU
Memory
8
13
CIS360
MDR
2 to 1
MUX
Note: there is no control
signal in the current
architecture opposite of
5 (Load MAR), so we
would have to create a
new control signal
(MAR to bus) in
addition to creating these
new states.
Op
Decode
14
80
7
New State 12 (Old 3): Control Signals 12, 5
Put (reload) the address from the instruction in the Address Register.
INC
Addr -> bus
load MAR
Addr
Op
2 to 1
MUX
Decode
3
Timing and
Control
PC
IR
2
9
12
Bus
4
5
6
7
0
10
1
MAR
MDR
2 to 1
MUX
ACC
11
ALU
Memory
8
13
CIS360
14
81
New State 13 (Old 5): Control Signals 13
Write the data from the Data Register to the address stored in the MAR.
INC
Addr
CS
Op
2 to 1
MUX
Decode
3
Timing and
Control
PC
IR
2
9
12
Bus
4
5
6
0
10
1
MAR
MDR
2 to 1
MUX
ACC
11
ALU
Memory
8
13
CIS360
14
82
7
New Instruction Example Summary
Changes to States, added 9 thru 13
Changes to Signals, added 15: MAR -> bus
Changes to Fetch/Execute, new register transfer language (RTL)
PC -> bus, load MAR, INC -> PC, Load PC
CS, R/w
MDR -> bus, load IR
Addr -> bus, load MAR
CS, R/w
MDR -> bus, load MAR
ACC -> bus, load MDR
MAR -> bus, load ACC
Addr -> bus, load MAR
CS
CIS360
83
Instruction Set Architectures 1
RISC vs. CISC
– Complex Instruction Set Computer (CISC): many,
powerful instructions. Grew out of the need for high
code density. Instructions have varying lengths,
number of operands, formats, and clock cycles in
execution.
– Reduced Instruction Set Computer (RISC): fewer, less
powerful, optimized instructions. Grew out of
opportunity for simpler, faster hardware. Instructions
have fixed length, number of operands, formats, and
similar number of clock cycles in execution.
CIS360
84
Instruction Set Architectures 2
Motivation: memory is comparatively slow.
– 10x to 20x slower than processor.
– Need to minimize number of trips to memory.
Provide faster storage in the processor -- registers.
Registers (16, 32, 64 bits wide) are used for intermediate
storage for calculations, or repeated operands.
Accumulator machine
– One data register -- ACC.
– 2 memory accesses per instruction -- one for the instruction and
one for the operand.
CIS360
Add more registers (R0, R1, R2, …, Rn)
85
Instruction Set Architectures 3
How many addresses to specify?
– With binary operations, need to know two source
operands, a destination, and the operation.
E.g., op (dest_operand) (src_op1) (src_op2)
– Based on number of operands, could have:
CIS360
3 addr. machine: both sources and dest are named.
2 addr. machine: both sources named, dest is a source.
1 addr. machine: one source named, other source and dest. is
the accumulator.
0 addr. machine: all operands implicit and available on the
stack.
86
Instruction Set Architectures 4
1-address architecture: a:=ab+cde
– Memory only
Code
LOAD
MPY
STORE
LOAD
MPY
MPY
ADD
STORE
# mem refs
100
104
100
108
112
116
100
100
2
2
2
2
2
2
2
2
Using registers
Code
LOAD
MPY
STORE
LOAD
MPY
MPY
ADD
STORE
# mem refs
100
104
R2
108
112
116
R2
100
2
2
1
2
2
2
1
2
1½-address architecture: one operand must always be a
register. (½ address is register, 1 address is the memory
operand: LOAD 100, R1).
– Like an accumulator machine, but with many accumulators.
CIS360
87
Instruction Set Architectures 5
3-address architecture: a:=ab+cde
– Using memory only:
Code
MPY
MPY
MPY
ADD
100,
200,
200,
100,
# mem refs
100,
108,
116,
200,
104
112
200
100
;a:=ab
;t:=cd
;t:=et
;a:=t+a
Memory
– Using registers:
Code
MPY
MPY
MPY
ADD
R2, 100,
R3, 108,
R3, 116,
100, R3,
# mem refs
104
112
R3
R2
;t1:=ab
;t2:=cd
;t2:=et2
;a:=t1+t2
100
104
108
112
116
...
200
(a)
(b)
(c)
(d)
(e)
(t)
– What about instruction size?
CIS360
88
Instruction Set Architectures 6
2-address architecture: a:=ab+cde
– Using memory only:
Code
MPY
MOVE
MPY
MPY
ADD
# mem refs
100,
200,
200,
200,
100,
104
108
112
116
200
;a:=ab
;t:=c
;t:=td
;t:=te
;a:=t+a
4
3
4
4
4
– Using registers:
Code
MPY 100,
MOVE R2,
MPY R2,
MPY R2,
ADD 100,
# mem refs
104
108
112
116
R2
;a:=ab
;R2:=c
;R2:=R2d
;R2:=R2e
;a:=t+a
4
2
2
2
3
Memory
100
104
108
112
116
...
200
(a)
(b)
(c)
(d)
(e)
(t)
– Most CISC arch. this way, making 1 operand implicit
CIS360
89
Instruction Set Architectures 7
0-address architecture: a:=ab+cde
– Stack machine: All operands are implicit. Only push
and pop touch memory. All other operands are pulled
from the top of stack, and result is pushed on top.
E.g., HP calculators.
Code
PUSH A
PUSH B
MPY
PUSH C
PUSH D
PUSH E
MPY
MPY
ADD
POP A
CIS360
# mem refs
2
2
1
2
2
2
1
1
1
2
Stack
4
3
2
1
0
90
Instruction Set Architectures 8
Load/Store Architectures -- RISC
– Use of registers is simple and efficient. Therefore, the
only instructions that can access memory are load and
store. All others reference registers.
Code
LOAD
LOAD
LOAD
LOAD
LOAD
MPY
MPY
MPY
ADD
STORE
CIS360
# mem refs
R2, 100
R3, 104
R4, 108
R5, 112
R6, 116
R2, R2,
R3, R4,
R3, R3,
R2, R2,
100, R2
R3
R5
R6
R3
;R2a
;R3b
;R4c
;R5d
;R6e
;R2ab
;R3cd
;R3(cd)e
;R2ab+(cd)e
;aab+(cd)e
2
2
2
2
2
1
1
1
1
2
91
Instruction Set Architectures 9
Why load/store architectures?
– Number of instructions (hence, memory references to fetch them)
is high, but can work without waiting on memory.
– Claim: overall execution time is lower. Why?
Clock cycle time is lower (no micro code interpretation).
More room in CPU for registers and memory cache.
Easier to overlap instruction execution through pipelining.
– Side effects:
CIS360
Register interlock: delaying execution until memory read completes.
Instruction scheduling: rearranging instructions to prevent register
interlock (loads on SPARC) and to avoid wasting the results of
pipelined execution (branches on SPARC).
92
SPARC Assembly Language 1
SPARC (Scalable Processor ARChitecture)
– Used in Sun workstations, descended from RISC-II
developed at UC Berkeley
– General Characteristics:
32-bit word size (integer, address, register size, etc.)
Byte-addressable memory
RISC load/store architecture, 32-bit instruction, few addressing
modes
Many registers (32 general purpose, 32 floating point, various
special purpose registers)
– ISEM: Instructional SPARC Emulator - nicer than a
real machine for learning to write assembly language
programs.
CIS360
93
SPARC Assembly Language 2
Structure
– Line oriented: 4 types of lines
Blank - Ignored
Labeled – Any line may be labeled. Creates a
symbol in listing. Labels must begin
with a letter (other than ‘L’), then any
alphanumeric characters. Label must
end with a colon “:”. Label just
assigns a name to an address.
Assembler Directives - E.g., .data
.word .text, etc.
Instructions
– Comments start after “!” character and
go to the end of the line.
CIS360
.data
x_m:
y_m:
z_m:
.word 0x42
.word 0x20
.word 0
.text
start:
set
ld
set
ld
x_m, %r2
[%r2], %r2
y_m, %r3
[%r3], %r3
! Load x into reg 2
! Load y into reg 3
94
SPARC Assembly Language 3
Directives: Instructions to the assembler
– Not executed by the machine
.data -- following section contains declarations
– Each declaration reserves and initializes a certain number of bits
of storage for each of zero or more operands in the declaration.
• .word -- 32 bits
• .half -- 16 bits
• .byte -- 8 bits
E.g.,
w:
x:
y:
z:
CIS360
.data
.half
.byte
.byte
.word
27000
8
’m’, 0x6e, 0x0, 0, 0
0x3C5F
.text -- following section contains executable instructions
95
SPARC Assembly Language 4
Registers -- 32 bits wide
– 32 general purpose integer registers, known by several
names to the assembler
%r0-%r7 also known as %g0-%g7 global registers -- Note,
%r0 always contains value 0.
%r8-%r15 also known as %o0-%o7 output registers
%r16-%r23 also known as %l0-%l7 local registers
%r24-%r31 also known as %i0-%i7 input registers
Use the %r0-%r31 names for now. Other names are used in
procedure calls.
– 32 floating point registers %f0-%f31. Each reg. is
single precision. Double prec. uses reg. pairs.
CIS360
96
SPARC Assembly Language 5
Assembly language
– 3-address operations - format different from book
op src1, src2, dest !opposite of text
E.g.,
add %r1, %r2, %r3
!%r3 %r1 + %r2
or
%r2, 0x0004, %r2 !%r2 %r2 b-w-or 0x0004
– Contrast SPARC with MiPs (used in the book)
CIS360
indirect address notation: @addr vs [addr]
operand order, especially the destination register
register notation: R2 vs. %r2
branches
97
SPARC Assembly Language 6
– 2-address operations: load and store
ld [addr], %r2
st %r2, [addr]
! %r2 M[addr]
! M[addr] %r2
Often use set to put an address (a label, a symbolic constant)
into a register, followed by ld to load the data itself.
set x,
%r1 !put addr x into %r1
ld [%r1],%r2 !use addr in %r1 to load %r2
– Immediate values: instruction itself contains some data
to be used in execution.
CIS360
98
SPARC Assembly Language 7
– Immediate values (continued)
E.g., add %rs, siconst13, %rd !%rd%rs+const
Constant is coded into instruction itself, therefore available
after fetching the instruction (no extra trip to memory for an
operand).
On SPARC, no special notation for differentiating constants
from addresses because no ambiguity in a load/store
architecture.
Immediate value coded in 13 bit sign-extended value. Range
is, then, -212…212-1 or -4096 to 4095.
Immediate values can be specified in decimal, hexadecimal, or
octal.
E.g., add %r2, 0x1A, %r2 ! %r2 %r2 + 26
CIS360
99
SPARC Assembly Language 8
– Synthetic Instructions: assembler translates one
“instruction” into several machine instructions.
CIS360
set : used to load a 32-bit signed integer constant into a
register. Has 2 operands - 32 bit value and register number.
How does that fit into a 32 bit instruction?
E.g., set iconst32, %rd
set -10, %r3
set x, %r4
set ’=’, %r8
clr %rd : used to set all bits in a register to 0. How?
mov %rs, %rd : copies a register.
neg %rs, %rd : copies the negation of a register.
100
SPARC Assembly Language 9
– Operand sizes
–
set
ld
ldsb
ldub
x, %r2
[%r2], %r1
[%r2], %r1
[%r2], %r1
!Put addr x in %r2
!load word
!load byte, sign extended
!load byte, extend with 0’s
st
stb
sth
%r1, [%r2] !store word, addr is mult of 4
%r1, [%r2] !store byte, any address
%r1, [%r2] !store half word, address is even
Characters use 8 bits
CIS360
double word = 8 bytes, word = 4 bytes, half word = 2 bytes,
byte = 8 bits. Recall memory alignment issues.
ldub to load a character
stb to store a character
101
SPARC Assembly Language 10
– Traps : provides initial help with I/O, also used in
operating systems programming.
ta 0 : terminate program
ta 1 : output ASCII character from %r8
ta 2 input ASCII character into %r8
ta 4 : output integer from %r8 in unsigned hexadecimal
ta 5 : input integer into %r8, can be decimal, octal, or hex
E.g.,
set ’=’, %r8
ta 1
ta 5
mov %r8, %r1
set 0x0a, %r8
ta 1
CIS360
!put ’=’ in %r8
!output the ’=’
!read in value into %r8
!copy %r8 into %r1
!load a newline into %r8
!output the newline
102
SPARC Assembly Language 11
– More assembler directives (.asciz and .ascii):
Each of the following two directives is equivalent:
– msg01: .asciz "a phrase"
– msg01: .byte 'a', ' ', 'p', 'h', 'r'
.byte 'a', 's', 'e', 0
Note that .asciz generates one byte for each character between
the quote (") marks in the operand, plus a null byte at the end.
The .ascii directive does not generate that extra byte. Each of
the following three directives is equivalent:
– digits: .ascii "0123456789"
– digits: .byte '0', '1', '2', '3', '4', '5'
.byte '6', '7', '8', '9'
– digits: .byte 0x30, 0x31, 0x32, 0x33, 0x34
.byte 0x35, 0x36, 0x37, 0x38, 0x39
CIS360
103
SPARC Assembly Language 12
– Quick review of instructions so far:
ld [addr], %rd
st %rd, [addr]
op %rs1, %rs2, %rd
op %rs, siconst13, %rd
set siconst32, %rd
ta #
!
!
!
!
!
!
%rd M[addr]
M[addr] %r2
op is ALU op
%rd%rs op const
%rdconst
trap signal
– Have actually seen many more variants, e.g., ldub,
ldsb, sth, clr, mov, neg, add, sub, smul, sdiv,
umul, udiv, etc. Can evaluate just about any simple
arithmetic expression.
CIS360
104
Review: Sparc Loads, Stores
.data
x_m:
.word 0xa1b2c3d4
.skip 12
.text
set x_m, %r2
ld [%r2], %r3
ldsb [%r2], %r4
ldub [%r2], %r5
st %r3, [%r2+4]
sth %r3, [%r2+8]
stb %r3, [%r2+12]
ta 0
After this runs, what values are in %r2-5, and memory locations starting at byte address x_m?
CIS360
105
Flow of Control 1
In addition to sequential execution, need ability to
repeatedly and conditionally execute program fragments.
– High level language has: while, for, do, repeat, case, if-then-else,
etc.
– Assembler has if, goto.
– Compare: high level vs. pseudo-assembler, implementation of f=n!
f = 1;
i = 2;
while (i <= n)
{
f = f * i;
i = i + 1;
}
CIS360
f = 1
i = 2
loop: if (i > n) goto done
f = f * i
i = i + 1
goto loop
done: ...
106
Flow of Control 2
– Branch -- put a new address in the program counter.
Next instruction comes from the new address,
effectively, a “goto”.
– Unconditional branch
(book)
(SPARC)
BRANCH
ba
addr
addr
! PC addr
! PC addr
– Conditional branch
CIS360
(book) BRcc R1, R2, target
“if R1 cc R2 then PC target” and cc is comparison
operation (e.g., LT is <, GE is , etc.)
107
Flow of Control 3
– Evaluating conditional
branches
Evaluate condition
If condition is true, then
PC target, else PC
PC+1
– Consider changes to the
fetch-execute cycle given
earlier for accumulator
machine. What needs to
change?
CIS360
PC to bus, etc.
Fetch
Addr to bus, load
PC
Yes
OP=
BRANCH
No
Yes
Yes
Cond=T
No
OP=BRcc
Execute
No
108
Flow of Control 4
Other conditions (from text, very similar to MIPS)
BRLT
BRLE
BREQ
BRNE
BRGE
BRGT
Rn,
Rn,
Rn,
Rn,
Rn,
Rn,
Rm,
Rm,
Rm,
Rm,
Rm,
Rm,
;
;
;
;
;
;
if
if
if
if
if
if
Rn <
Rn
Rn
Rn
Rn
Rn
Rm
Rm
Rm
Rm
Rm
Rm
then
then
then
then
then
then
PCtarget
PCtarget
PCtarget
PCtarget
PCtarget
PCtarget
Can implement high level control structures now. Back to the
factorial example using the book’s assembly language:
LOAD
LOAD
LOAD
loop: BRGT
MPY
ADD
BRANCH
done: STORE
CIS360
target
target
target
target
target
target
R1,
R2,
R3,
R2,
R1,
R2,
loop
f,
#1
#2
n
R3,
R1,
R2,
R1
done
R2
#1
;
;
;
;
;
;
;
;
R1 = f = 1
R2 = i = 2
R3 = n
branch if i > n
f = f * i
i = i + 1
goto loop
f = n!
109
Flow of Control 5
– Condition Codes
Book’s assembly language has 3-address branches. SPARC
uses 1-address branches. Must use condition codes.
Non-MIPS machines use condition codes to evaluate branches.
Condition Code Register (CCR) holds these bits. SPARC has
4-bit CCR.
N
CIS360
Z
V
C
N: Negative, Z: Zero, V: Overflow, C: Carry. All are shown in
a trace, or in the reg command under ISEM.
Condition codes are not changed by normal ALU instructions.
Must use special instructions ending with cc, e.g., addcc.
110
Flow of Control 6
.text
start:
set 1, %r2
set 0xFFFFFFFE, %r1
cc_set: subcc %r1, %r2, %r3
end:
ta 0
ISEM> reg
----0--- ----1--G 00000000 fffffffe
O 00000000 00000000
L 00000000 00000000
I 00000000 00000000
PC: 08:00000028
cc_set
ISEM> trace
----0--- ----1--G 00000000 fffffffe
O 00000000 00000000
L 00000000 00000000
I 00000000 00000000
PC: 08:0000002c
CIS360
----2--- ----3--00000001 00000000
00000000 00000000
00000000 00000000
00000000 00000000
nPC: 0000002c
:
subcc
! –2 in 32-bit 2’s comp
! r3<= -2-1
----4--- ----5--- ----6--- ----7--00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000
PSR: 0000003e
N:0 Z:0 V:0 C:0
%g1, %g2, %g3
----2--- ----3--00000001 fffffffd
00000000 00000000
00000000 00000000
00000000 00000000
nPC: 00000030
----4--- ----5--- ----6--- ----7--00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000
00000000 00000000 00000000 00000000
PSR: 00b0003e
N:1 Z:0 V:0 C:0
111
Flow of Control 7
– Setting the condition codes
Regular ALU operations don’t set condition codes.
Use addcc, subcc, smulcc, sdivcc, etc., to set condition
codes.
E.g., Suppose %r1 contains -4 and %r2 contains 5.
N
addcc
subcc
subcc
subcc
CIS360
%r1,
%r1,
%r2,
%r1,
%r2,
%r2,
%r1,
%r1,
Z
V
C
%r3
%r3
%r3
%r3
112
ALU Hardware 1
How does a computer add?
– Design a circuit that adds three single digit binary
numbers. Results in a sum, and a carry out.
Cin
0
1
0
1
0
1
0
1
X
0
0
0
0
1
1
1
1
Y
0
0
1
1
0
0
1
1
Sum
0
1
1
0
1
0
0
1
Cout
0
0
0
1
0
1
1
1
x
cin
y
x
cout
y
cin
FA
Sum
Sum
1
cout
CIS360
113
ALU Hardware 2
Now cascade the full adder hardware
register x
cout
FA
FA
register y
FA
FA
FA
0
register z
How are CCR bits set? (Above is a ripple-carry adder.)
–
–
–
–
CIS360
C-bit = Cout
V-bit = Cout Cn-1
Z-bit = (rzn-1 rzn-2 rzn-3 ... rz0)
N-bit = rzn-1
114
Flow of Control 8
– Branches use logic to evaluate CCR (SPARC)
Operation
CIS360
Assembler Syntax
Branch Condition
Branch always
ba
target
1 (always)
Branch never
bn
target
0 (never)
Branch not equal
bne
target
Z
Branch equal
be
target
Z
Branch greater
bg
target
(Z (N V))
Branch less or equal
ble
target
(Z (N V))
Branch greater or equal
bge
target
(N V)
Branch less
bl
target
NV
Branch greater, unsigned
bgu
target
(C Z)
Branch less or equal, unsigned
bleu
target
CZ
Branch carry clear
bcc
target
C
Branch carry set
bcs
target
C
Branch positive
bpos
target
N
Branch negative
bneg
target
N
Branch overflow clear
bvc
target
V
Branch overflow set
bvs
target
V
115
Flow of Control 9
– Setting Condition Codes (continued)
Synthetic instruction cmp %rs1, %rs2
– Sets CCR, but doesn't modify any registers.
– Implemented as subcc %rs1, %rs2, %g0
Back to the factorial example (SPARC)
loop:
done:
CIS360
set 1, %r1
set 2, %r2
set n, %r3
ld [%r3], %r3
!
!
!
!
%r1
%r2
Get
Put
= f = 1
= i = 2
loc of n
n in %r3
cmp %r2, %r3
bg done
nop
! Set CCR (i?n)
! i > n done
! Branch delay
umul %r1, %r2, %r1
add %r2, 1, %r2
! f = f * i
! i = i + 1
ba loop
nop
! Goto loop
! Branch delay
set f, %r3
st %r1, [%r3]
! Get loc of f
! f = n!
116
Flow of Control 10
– Branch delay slots: unique to RISC architecture
Non-technical explanation: processor is running so fast, it can’t
make a quick turn.
– Instruction following branch is always executed.
CIS360
Technical explanation: the efficiency advantage of pipelining is
greater if the following instruction, which has almost
completed execution, is allowed to complete.
Compilers take advantage of branch delay slots by putting a
useful instruction there if possible.
For our purposes, use the nop (no operation) instruction to fill
branch delay slots. Beware! Forgetting the nop will be a
large source of errors in your programs!
117
High Level Control Structures 1
Converting high level control structures
– You get to be the “compiler”.
Some compilers convert the source language (C, Pascal,
Modula 2, etc.) into assembly language and then assemble the
result to an object file. GNU C, C++ do this to GAS (Gnu
Assembler).
– if-then-else, while-do, repeat-until are all possible to
create in a structured way in assembly language.
CIS360
118
High Level Control Structures 2
General guidelines
– Break down into independent (or nested) logical units
– Convert to if/goto pseudo-code.
f = 1;
for (i=2; i<=n; i++)
f = f * i;
f=1
i=2
loop: if (i>n) goto done
f = f*i
i = i+1
goto loop
done: ...
– Mechanical, step-by-step, non-creative process
CIS360
119
High Level Control Structures 3
if-then-else
if (a<b)
c = d + 1;
else
c = 7;
init: set
ld
set
ld
if:
cmp
bge
nop
set
ld
add
ba
nop
else: set
end: set
st
if/goto
if (a >= b) goto else
c = d + 1
goto end
else: c = 7
end:
CIS360
a,
[%r2],
b,
[%r3],
%r2,
else
%r2
%r2
%r3
%r3
%r3
d,
%r5
[%r5], %r5
%r5, 1, %r4
end
7,
c,
%r4,
!
!
!
!
!
!
get &a into r2
get a into r2
get &b into r3
get b into r3
a ?? b (want >=)
a >= b, do then
! get &d into r5
! get d into r5
! r4 <- d+1
%r4
! get 7 into r4
%r5
! get &c into r5
[%r5] ! c <- r4
120
High Level Control Structures 4
while loops:
while (a<b)
a = a+1;
c = d;
if/goto:
init: set
ld
set
ld
whle: cmp
bge
nop
body: add
st
ba
nop
done: set
...
a,
[%r4],
b,
[%r3],
%r2,
done
%r4
%r2
%r3
%r3
%r3
!
!
!
!
!
!
get &a into r4
get a into r2
get &b into r3
get b into r3
a ?? b (want >=)
a >= b skip body
%r2, 1, %r2
! r2 = a + 1
%r2,
[%r4] ! a = a + 1
whle
! repeat loop body
c,
%r5
! get &c into r5
whle: if (a>=b) goto done
body: a = a+1
goto whle
done: c = d
CIS360
121
High Level Control Structures 5
repeat-until loops:
rpt:
repeat
…
until (a>b)
...
...
set
ld
set
ld
cmp
ble
nop
a,
[%r2],
b,
[%r3],
%r2,
rpt
%r2
%r2
%r3
%r3
%r3
;
;
;
;
;
;
get &a into r2
get a into r2
get &b into r3
get b into r3
a <= b?
do body again
if/goto:
repeat:
…
if (a<=b) goto repeat
CIS360
122
High Level Control Structures 6
Complex condition
if((a<b)and(b>=c))
…
if((a<b)or(b>=c))
…
These can be combined
and used in if/else or
while loops.
CIS360
Primitive Language
if (a>=b) then goto skip
if (b<c) then goto skip
body: ...
...
skip: ...
Primitive Language
if (a<b) then goto body
if (b<c) then goto skip
body: ...
...
skip: ...
123
Flow of Control 11
– Optimizing code: change order of instructions, combine
instructions, take advantage of branch delay slots.
Factorial example again. (for i:=n downto 1 do…)
loop:
CIS360
set 1, %r1
set n, %r2
ld [%r2], %r2
umul %r1, %r2, %r1
subcc %r2, 1, %r2
bg loop
nop
set f, %r3
st %r1, [%r3]
!
!
!
!
!
!
!
!
!
%r1=f=1
Get loc of n
Put n in %r2
f=f*n
Decrement n
Repeat
Branch delay
Get loc of f
f=n!
Reduced 7 instructions in loop to just 4.
(You gain no advantage if you optimize code in your labs.)
124
Synthetic Instructions
Remember lab0?
x_m:
y_m:
z_m:
.data
.word 0x42
.word 0x20
.word 0
.text
start:
set
ld
set
x_m, %r2
[%r2], %r2
y_m,%r3
ld
[%r3], %r3
and so on…
Suppose you gave this command to ISEM (after loading):
ISEM> dump start
start
05 00 00 10 84 10 a0 00 c4 00 80 00 07 00 00 10
Could you find the set instruction?
CIS360
125
Instruction Encodings 1
First, Instruction Encoding is how instructions are
assembled
– All instructions must fit into 32 bits.
Register-register: op=10, i=0
31 30 29
op
op3
14 13 12
rs1
i
54
asi
rs2
rd
op3
rs1
i
simm13
Floating point: op=10, i=0
op
CIS360
rd
19 18
Register-immediate: op=10, i=1
op
25 24
rd
op3
rs1
i
opf
rs2
126
Instruction Encodings 2
Call instructions: op=01
31 30 29
op
Branch instructions: op=00, op2=010
31 30 29 28
25 24 22 21
op ia
op2
cond
disp22
SETHI instructions: op=00, op2=100
op
disp30
rd
op2
imm22
Ex.: add %r2, %r3, %r4
31 30 29
10
25 24
00100
19 18
000000
14 13 12
00010
0
54
00000000
00011
in hexadecimal: 88008003
CIS360
127
Understanding SET Synthetic
Usually used to put the value of an address in memory into a register.
For example, set 0x4004, %r3
Can do neither ‘add %r0, 0x4004, %r3’ nor ‘or %r0, 0x4004, %r3’. Why not?
SET is a synthetic instruction which may be implemented in two steps.
bit positions
#1
#2
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
sethi 0x10, %r3 ! Puts 0x10 in the Most Significant 22 bits
%r3
0 0 0 1 0 0 1 0 0 1 0
0x10
0 0 0 0 0 0 0 0 0 0 0
sethi
%r3
0 0 0 0 0 0 0 0 0 0 0
9
8
7
6
5
4
3
2
1
0
0
0
1
0
0
0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
hex value
0 1 0 0 1 0 0 1 0 0 0 0x12481248
0 x x x x x x x x x x 0x10
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0 0x4000
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0 0x4000
0 0x00000004
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
1
0
0 0x4004
0
0
0
0
0
0
0
1
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0 0x 07 00 00 10
0 0x 86 10 E0 04
or %r3, 0x0004, %r3 ! Puts 0x0004 in the least significant bits
%r3
0 0 0 0 0 0 0 0 0 0 0 0
0x0004
0 0 0 0 0 0 0 0 0 0 0 0
OR
%r3
0 0 0 0 0 0 0 0 0 0 0 0
Machine language encoding for 'set 0x4004, %r3'
sethi 0x10, %r3
or %r3, 4, %r3
CIS360
0
1
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
0
1
0
0
128
Decoding an Instruction
05 00 00 1016
0000 0101 0000 0000 0000 0000 0001 00002
Instruction Group (bits 30:31) = 00
Destination Register (bits 25:29) = 00010
Op Code (bits 22:24) = 100
Constant (bits 0:21) = 0000000000000000010000
Meaning: sethi 0x10, %r2
%r2 <-- 00000000000000000100000000000000 (0x4000)
CIS360
129
More Decoding
Binary
84 10 A0 00
Group O
P
Rd
Rs1
Rs2 SICONST
1000 0100 0001 0000 1010 0000 0000 0000
C4 00 80 00
07 00 00 10
86 10 E0 04
CIS360
130
SET Synthetic Instruction
set iconst, rd
sethi
or
sethi
or
CIS360
%hi(iconst), rd
rd, %lo(iconst), rd
--or-%hi(iconst), rd
--or-%g0, iconst, rd
131
Bitwise Operations 1
Bit Manipulation Instructions
– Bitwise logical operations
and %rs1, %rs2, %rd
10010011… (32 bits)
01111001…
or
%rs1, %rs2, %rd
10010011… (32 bits)
01111001…
xor %rs1, %rs2, %rd
10010011… (32 bits)
01111001…
CIS360
x
0
0
1
1
y
0
1
0
1
x y
0
0
0
1
x
0
0
1
1
y
0
1
0
1
x+y
0
1
1
1
x
0
0
1
1
y
0
1
0
1
xy
0
1
1
0
132
Bitwise Operations 2
andn %rs1, %rs2, %rd
10010011… (32 bits)
01111001…
orn %rs1, %rs2, %rd
10010011… (32 bits)
01111001…
not %rs, %rd
10010011… (32 bits)
CIS360
x
0
0
1
1
y
0
1
0
1
xy
0
0
1
0
x
0
0
1
1
y
0
1
0
1
xy
1
0
1
1
x
0
1
x
1
0
Recall the cc operations, so andcc, orcc, etc. are available.
(However, there is no notcc; use xnorcc.)
133
Bitwise Operations 3
CIS360
For what kinds of things are these bit level operations used?
Recall the synthetic operation clr, and mov.
clr %r2
or %r0, %r0, %r2
mov %r2 %r3
or %r0, %r2, %r3
Masking operations: Want to select a bit or group of bits from
a set of 32. E.g., convert lower (or upper) to upper case:
‘a’ in binary is 01100001
‘A’ in binary is 01000001
All we need to do is “turn off” the bit in position 5.
0xDF in binary is 11011111
and %r1, 0xDF, %r1 will turn off that bit!
What if we subtract 32 from %r1?
What about converting upper to lower case?
134
Bitwise Operations 4
– Bitwise shifting operations
Shift logical left: sll %rs1, %rs2, %rd
%rs1: data to be shifted
%rs2: shift count
%rd: destination register
E.g.,
set 0xABCD1234, %r2
sll %r2, 3, %r3
%r2: 1010 1011 1100 1101 0001 0010 0011 0100
%r3: 0101 1110 0110 1000 1001 0001 1010 0000
CIS360
sll is equivalent to multiplying by a power of 2 (barring
overflow). (In the decimal system, what’s a shortcut for
multiplying by a power of ten?)
135
Bitwise Operations 5
Shift Logical Right: srl %rs1, %rs2, %rd
– Shifts right instead of left, inserting zeros.
Arithmetic shifts: propagate the sign bit when shifting right,
e.g., sra. (Left shift doesn't change.)
– Equivalent to dividing by a power of 2.
Rotating shifts: Bits that would have gone into the bit bucket
are shifted in instead. (E.g., rr, rl)
Rotate Right
Rotate Left
– Rotate not implemented in SPARC
CIS360
136
More SPARC Assembly Language
Assembler directives
Are not encoded as machine instructions
Memory alignment: .align 4
– Used when mixing allocations of bytes, words, halfwords, etc.
and need word boundary alignment
Reserve bytes of space: .skip 20
– Useful for allocating large amounts of space (e.g., arrays)
Create a symbolic constant: .set mask, 0x0f
– Can now use the word “mask” anywhere we could use the
constant 0x0f previously
All this is leading to additional addressing modes, which
help us work with pointers, arrays, and records in
assembly language.
CIS360
137
Addressing Modes 1
Addressing Modes
– How do we specify operand values?
In a register, location is encoded in the instruction.
As a constant, immediate value is in the instruction.
In memory, operand is somewhere in memory, location may
only be known at runtime.
– Memory operands:
CIS360
Effective address: actual location of operand in memory. This
may be calculated implicitly (e.g., by a displacement in the
instruction) or may be calculated by the programmer in code.
138
Addressing Modes 2
– Summary of addressing modes:
Mode
Immediate
Register Direct
Memory Direct
Memory Indirect
Register Indirect
Register Indexed
Register
Displaced
Post Increment
Example
add %r1, 100, %r1
add %r1, %r2, %r1
add %r1, [2000], %r2
add %r1, [[2000]], %r2
ld [%r1], %r2
st %r1, [%r2+%r3]
st %r1, [%r2+x]
Loc. Of Operand
instruction
%r2
mem[2000]
mem[mem[2000]]
mem[%r1]
mem[%r2+%r3]
mem[%r2+x]
Suitable for
SPARC?
Constants
Integers, constants
Integers, constants
Pointers
Pointers
Arrays
Records
Yes
Yes
No
No
Yes
Yes
Yes
ld [%r1]+, %r2
ld -[%r1], %r2
Arrays, strings,
stacks
Arrays, strings,
stacks
No
Pre Decrement
mem[%r1]
increment %r1
decrement %r1,
mem[%r1]
CIS360
No
139
Addressing Modes 3
– Memory Direct addressing
Entire address is in the instruction (not in SPARC).
E.g., accumulator machine: each instruction had an opcode and
a hard address in memory.
– Can’t be done on SPARC because an address is 32 bits, which is
the length of an instruction. No room for opcodes, etc. Can be
done in CISC because multi-word instructions are permitted.
– Memory Indirect addressing
CIS360
Pointer to operand is in memory. Instruction specifies location
of pointer. Requires three memory fetches (one each for
instruction, pointer, and data). Not in RISC machines because
instruction is too slow; such an instruction would cause its own
register interlock!
140
Addressing Modes 4
– Register Indirect addressing
Register has address of operand (a pointer). Instruction
specifies register number, effective address is contents of
register.
Ex.:
.data
n_m: .word
.text
set
ld
CIS360
5
; initialize n to 5
n_m, %r1
[%r1], %r3
; %r1 has n_m, pointer to n
; fetch n into %r3
141
Addressing Modes 5
n_m:
a_m:
sum_m:
b_m:
loop:
.data
.word
.word
.word
.skip
Ex.: sum up array of integers:
5
4,2,5,8,3
0
5*4
!
!
!
!
.text
clr %r2
!
set n_m, %r3
!
ld [%r3], %r3
!
set a_m, %r4
!
ld [%r4], %r5
!
add %r5, %r2, %r2 !
add %r4, 4, %r4 !
subcc %r3, 1, %r3 !
bg loop
!
nop
!
set sum_m, %r1
!
st %r2, [%r1]
!
ta 0
!
CIS360
Size of array
5 word array
Sum of elements
another 5 word array
r2 will hold sum
r3 points to n
r3 gets array size
r4 points to array a
Load element of a into r5
sum = sum + element
Incr ptr by word size
Decrement counter
Loop until count = 0
Branch delay slot
r1 points to sum
Store sum
done
5
4
2
5
8
3
r2 r3
0
5
4
3
2
1
n_m
a_m
a_m+4
a_m+8
a_m+12
a_m+16
sum_m
r4
r5
Pre-loop
a_m
loop
a_m+4
loop+1
a_m+8
loop+2
a_m+12
loop+3
a_m+16
142
Addressing Modes 6
C-style example of pointer data type
char
x;
char * ptr;
ptr = &x;
*ptr = ‘a’;
x_m r1
ptr_m r2
‘a’ r3
x_m:
ptr_m:
//
//
//
//
object of type character
pointer to character type
ptr has address of x (points to x)
store ‘a’ at address in ptr
Assembly language equivalent
.data
x_m:
.byte 0
.align 4
ptr_m: .word 0
.text
set x_m, %r1
set ptr_m, %r2
st %r1, [%r2]
set ’a’, %r3
set ptr_m, %r2
ld [%r2], %r1
stb %r3, [%r1]
! reserve character space; x_m = &x; [x_m] = x
! align to word boundary
! pointer variable; [ptr_m] = ptr
!
!
!
!
!
!
!
get address x_m into %r1
get address ptr_m into %r2
make [ptr_m] point to [x_m]
put character ‘a’ into r3
get address ptr_m into %r2
get address [ptr_m], i.e. x_m, into %r1
store ‘a’ at address [ptr_m], i.e., ptr
‘a’
x_m, i.e., addr of x
CIS360
143
Addressing Modes 7
– Register Indexed addressing
.data
A: .skip
Suitable for accessing successive elements of the same type in
a data structure.
Ex.: Swap elements A[i] and A[k] in array
24*4
! reserve array[0..23] of int
! assume i is in %r2 and k is in %r3
.text
set
A,
%r4 ! beginning of array ptr.
sll
%r2, 2,
%r2 ! “multiply” i by 4
sll
%r3, 2,
%r3 ! “multiply” k by 4
ld
[%r2+%r4], %r7 ! r7 <- a[i]
r2 r3
ld
[%r3+%r4], %r8 ! r8 <- a[k]
st
%r8, [%r2+%r4] ! a[i] <- r8
001 0010
<- r7
st
%r7, [%r3+%r4] ! a[k] <=
100 1000
CIS360
A
A+4
A+8
A+12
r4
A
r7
r8
after sll
Effective address calculations!
144
Addressing Modes 8
Simulating Register Indirect addressing on SPARC
– SPARC doesn't truly have register indirect addressing. We can
write st %r2, [%r1] but assembler converts this
automatically into st %r2, [%r1+%r0]
Array mapping functions: used by compilers to determine
addresses of array elements. Must know upper bound, lower
bound, and size of elements of array.
–
–
–
–
CIS360
Total storage = (upper - lower + 1)*element_size
Address offset for element at index k = (k - lower)*element_size
Address (byte) offset for A[3] = (3-0)*4 = 12
This is for 1 dimensional arrays only!
145
Addressing Modes 9
1D array mapping functions: Want an array of n elements, each
element is 4 bytes in size, array starts at address arr.
–
–
–
–
Total storage is 4n bytes
First element is at arr+0
Last element is at arr+4(n-1)
kth (k can range from 0…n-1) element is at arr+4k. Array uses
zero-based indexing.
arr+0
k=0
arr+4
k=1
arr+8
k=2
arr+12
arr+16
arr+20
k=3
k=4
k=5
array of 6 elements, 4 bytes each
CIS360
146
Addressing Modes 10
2D array mapping functions: must linearize the 2D concept;
e.g., map the 2D structure into 1D memory.
0
1
2
3
4
0
0,0
0,1
0,2
0,3
0,4
1
1,0
1,1
1,2
1,3
1,4
2
2,0
2,1
2,2
2,3
2,4
3 Rows
(0...2)
5 Columns (0...4)
– Convert into 1D array in memory
0,0
CIS360
0,1
0,2
0,3
0,4
1,0
1,1
.....
2,3
2,4
147
Addressing Modes 11
2 ways to convert to 1D
– Row major order (Pascal, C, Modula-2) stores first by rows, then
by columns. E.g.,
0,0
0,1
0,2
0,3
0,4
1,0
1,1
.....
2,3
2,4
– Column major order (FORTRAN) stores first by columns then
by rows. E.g.,
0,0
1,0
2,0
0,1
1,1
2,1
0,2
.....
1,4
2,4
– Row major 2D array mapping function: Given an array starting
at address arr that is x rows by y columns, each element is m
bytes in size, and indices start at zero, then element (i, j) may be
found at location: arr + (y i + j) m
CIS360
148
Addressing Modes 12
3D array mapping function: natural extension of 2D function.
Store by row, then column, then depth.
+1
+3
+5
+7
+9
0,0,1 0,1,1 0,2,1 0,3,1 0,4,1
+0
+2 1,0,1
+4 1,1,1
+6 1,2,1
+8 1,3,1 1,4,1
0,0,0 0,1,0 0,2,0 0,3,0 0,4,0
+10
+122,0,1
+142,1,1
+162,2,1
+18 2,3,1
0,1,0 1,1,0 1,2,0 1,3,0 1,4,0
1,0,0
2,4,1
2,0,0 2,1,0 2,2,0 2,3,0 2,4,0
3 Rows, 5 Columns, 2 Depth
– Array starting at arr with x rows, y columns, depth z, m element
size. Element (i, j, k) is found at location:
arr + (z(yi + j) + k)m
CIS360
149
Addressing Modes 13
CALCULATE:
total storage
offset for A(i,j,k)
address for A(i,j,k)
element size (#bytes)
# rows (x)
# cols (y)
# depth (z)
starting addr (0)
i=
j=
k=
CIS360
1D
4
7
1
1
4
1
0
0
2D
2
3
5
1
8
1
1
0
3D
1
3
5
2
12
0
1
1
150
Addressing Modes 14
! Example that adds 1 to every element of columns 1 and 2, not 0, of a 5 by 3 array
.data
.set rows, 5
! define symbolic constants
.set cols, 3
arr_m:
.skip rows * cols * 4
! allocate space (.skip 60 same)
.text
...
set
arr_m, %r3
! get address of array
clr
%r1
! %r1 is i (row)
loop1:
cmp
%r1, rows
! done if i >= rows
bge
done
nop
set
1, %r2
! %r2 is j (col); start at one (skip col zero)
loop2:
cmp
%r2, cols
! if at last column, done with row
bge
inc1
nop
umul
%r1, cols, %r4
! # elements to skip for current row
add
%r4, %r2, %r4
! then which column being accessed
umul
%r4, 4, %r4
! change from element to byte offset
ld
[%r3+%r4], %r5
! get arr[i][j]
add
%r5, 1, %r5
! add 1 to the element value
st
%r5, [%r3+%r4]
! store it back to arr[i][j]
inc2:
add
%r2, 1, %r2
! next column
ba
loop2
! continue inner loop over columns
nop
inc1:
inc
%r1
! next row
ba
loop1
! continue outer loop over rows
nop
done:
...
CIS360
151
Addressing Modes 15
– Displacement Addressing
Suitable for accessing the individual fields of record data
structures. Each field can be of a different type.
20 Characters
Name
Age
Integer
DOB
Integer
Logical
view of a
record
Use .set directive to establish offsets to fields within records.
Then use displacement addressing to access those fields.
Actual layout of record in memory
20 bytes
person+0
CIS360
4 bytes
4 bytes
person+20
person+24
152
Addressing Modes 16
Ex.: Add 1 to the age field in a person record
.data
.set
name, 0
.set
age, 20
.set
dob, 24
person: .skip 28
!
!
!
!
offset to
offset to
offset to
size of a
name field
age field
date of birth
person record
!
!
!
!
get addr of person record
get the age of the person
increment age by 1
store back to record
.text
....
set
ld
add
st
person, %r1
[%r1+age], %r2
%r2, 1, %r2
%r2, [%r1+age]
CIS360
Problem: alignment in memory. May have to waste some
space in the person record in order to have the integer fields
align on a word boundary.
153
Addressing Modes 17
– Auto-increment and Auto-decrement addressing
CIS360
SPARC does not support these modes. They may be simulated
using register indirect addressing followed by an add or
subtract of the size of the element on that register.
Useful for traversing arrays forward (auto-increment) and
backward (auto-decrement). Also useful for stacks and queues
of data elements.
154
Subroutines 1
– Subroutines and subroutine linkage
Subroutines: programming mechanism to facilitate repeated
computations and modularization.
– Use of subroutines
CIS360
Basis for structured and disciplined programming
Compact code (no need to write monolithic loops)
Relatively easy to debug (no cut-and-paste errors)
Requires little hardware support, mostly protocols and
conventions to handle parameters.
155
Subroutines 2
– Terminology
CIS360
Caller: the code (which could be a subroutine itself) which
invokes the subroutine of interest
Callee: the subroutine being invoked by the caller
Function: subroutine that returns one or more values back to
the caller and exactly one of these values is distinguished as
the return value
Return value: the distinguished value returned by a function
156
Subroutines 3
– Terminology (continued)
CIS360
Procedure: a subroutine that may return values to the caller
(through the subroutine’s parameter(s)), but none of these
values is distinguished as the return value
Return address: address of the subroutine call instruction
Parameters: information passed to/from a subroutine (a.k.a.
arguments)
Subroutine linkage: a protocol for passing parameters between
the caller and the callee
157
Subroutines 4
– Subroutine linkage
Calling a subroutine
– Assembly language syntax for calling a subroutine
call label
nop
– Must change the program counter (as in a branch instruction) however,
we must also keep track of where to resume execution after the
subroutine finishes. Call instruction handles this atomically (i.e., without
interruption) by:
%r15 #PC
(PC #nPC)
nPC
label
Returning from a subroutine
– Assembly language syntax for returning from a subroutine
retl
nop
CIS360
158
Subroutines 5
Returning from a subroutine (continued)
– Again, must change the program counter to return to an
instruction after the one that called the subroutine. The address
of the instruction that called it was saved in %r15, and we must
skip over the branch delay slot as well. So, this is accomplished
by:
nPC %r15+8
Parameter passing: 2 approaches
– Register based linkage: pass parameters solely through registers.
Has the advantage of speed, but can only pass a few parameters,
and it won’t support nested subroutine calls. Such a subroutine
is called a leaf subroutine.
– Stack based linkage: pass parameters through the run-time stack.
Not as fast, but can pass more parameters and have nested
subroutine calls (including recursion).
CIS360
159
Register-based Linkage 1
– Subroutine linkage:
Startup
Sequence
Cleanup
Sequence
Prologue
Body
tl
CIS360
Callee
Caller
re
Startup Sequence: load
parameters and return
address into registers,
branch to subroutine.
Prologue: if non-leaf
procedure then save return
address to memory, save
registers used by callee.
Epilogue: place return
parameters into registers,
restore registers saved in
prologue, restore saved
return address, return.
Cleanup Sequence: work
with returned values
ca
ll
Epilogue
160
Register-based Linkage 2
– Example: Print subroutine.
main:
print:
CIS360
.text
set
set
mov
call
nop
mov
call
nop
add
call
nop
ta
set
or
mov
ta
mov
ta
retl
nop
1, %r1
3, %r2
%r1, %r8
print
! Initialize r1 and r2
%r2, %r8
print
! Print %r2
%r1, %r2, %r8
print
! Do our calculation
! Print the result (expect ‘4’)
0
‘0’, %r1
%r8, %r1, %r2
%r2, %r8
1
‘\n’, %r8
1
! Print %r1
!
!
!
!
Ascii value of zero
Treat r8 as parameter
Move into output register
Output character
! Output end of line (newline)
! Return
What’s wrong with the above code?
161
Register-based Linkage 3
– Which registers can leaf subroutines change?
Convention for optimized leaf procedures:
Register(s)
%r0
%r1
%r2-%r7
%r8
%r8-%r13
%r14
%r15
%r30
%r16-%r29, %r31
CIS360
Use
Zero
Temporary
Caller’s variables
Return value
Parameters
Stack pointer
Return address
Frame pointer
Caller’s variables
Changeable?
No
Yes
No
Yes
Yes
No
No
No
No
Any other registers the subroutine touches must be saved to memory
somewhere, and restored before returning to the caller.
Problem: how can a subroutine call another subroutine? How can a
subroutine call itself?
162
Register-based Linkage 4
– Example: procedure to print linked list of ints.
head
5
7
4
1
.data
.set dta, 0
.set ptr, 4
head: .word 0
! offset in record to data
! offset in record to next pointer
.text
main: . . . .
set head, %r8
ld
[%r8], %r8
call trav
nop
. . . .
!
!
!
!
!
nil
does all init and allocation of list
prepare parameter to traverse proc
follow head pointer to first node
call subroutine
branch delay
trav: mov %r8, %r1
! copy pointer to %r1
loop: cmp %r1, 0
! check for null pointer
be done
! null pointer means we are done
nop
! branch delay
ld [%r1+dta], %r8 ! follow pointer and get data field
ta 4
! print data field
ld [%r1+ptr], %r1 ! get pointer to next record
ba loop
nop
! branch delay
done: retl
nop
CIS360
163
Parameter Passing 1
– Parameter passing review:
CIS360
Pass by value copy: parameters to subroutine are copies upon
which the subroutine acts.
Pass by result copy: parameters are copies of results produced
by the subroutine.
Pass by reference copy: parameters to subroutine are (copies
of) addresses of values upon which the subroutine acts. Callee
is responsible for saving each result to memory at the location
referred to by the appropriate parameter.
Hybrid: some parameters passed by value copy, some by result
copy, and/or some by reference copy. Callee is responsible for
saving results for reference parameters.
164
Parameter Passing 2
– Parameter passing notes:
Array or record parameters typically are passed by reference
copy (efficiency reasons). Primitive data types may be passed
either way.
Conventions among languages allows any language to call
functions in any other language:
– Pascal: VAR parameters are passed by reference copy; all others
are passed by value copy.
– C: all parameters are passed by value copy. Must explicitly pass
a pointer if you want a reference parameter.
– C++: like Pascal, can pass by value or reference copy.
– FORTRAN: all things passed by reference copy (even constants).
– ADA: pass by value/result copy.
CIS360
165
Parameter Passing 3
.text
! Example 10.1 of Lab Manual
! pr_str – print a null terminated string
! Parameters: %r8 – pointer to string (initially)
!
! Temporaries: %r8 – the character to be printed
!
%r9 – pointer to string
!
pr_str:
mov %r8, %r9
! we need %r8 for the “ta 1” below
pr_lp:
ldub [%r9], %r8 ! load character
cmp %r8, 0
! check for null
be
pr_dn
nop
ta
1
! print character
ba
pr_lp
inc %r9
! increment the pointer (in
!
branch delay slot)
pr_dn:
retl
nop
CIS360
166
Parameter Passing 4
Summary from text (p. 220)
– Pass by value copy: For small “in” parameters. Subroutines
cannot alter the originals whose copies are passed as parameters.
– Pass by value/result copy: For small “in/out” parameters.
Caller’s cleanup sequence stores values of any “in/out”
parameters.
– Pass by reference copy: for “in/out” parameters of all sizes, and
large “in” parameters. “Out” values are provided by changing
memory at those addresses. (Note: pass by reference copy is
passing an address by value copy.)
CIS360
167
Parameter Passing 5
– Write Sparc code for the caller and callee for the
following subroutine using register based parameter
passing
!
!
!
!
!
!
!
!
!
!
!
!
!
!
global_function Integer subchr (A, B, C)
Substitutes character C for all B in string [A],
and returns count of changes.
// In comments, "[A+index]" is
index = 0
count = 0
LOOP: if [A+index]=0 go to END
if [A+index]B go to INC
[A+index]=C
count=count+1
INC: index=index+1
go to LOOP
END:
Assume
C_m:
B_m:
A_m:
R_m:
CIS360
denoted by "ch".
// while (ch != 0) {
//
if (ch == B) {
//
ch = C;
//
count++; }
//
index++;
// }
.data
! data section
.byte ’I’
! parameter C
.byte ’i’
! parameter B
.asciz "i will tip" ! parameter A
.align 4
.word 0
! for storing result count
168
Stack-based Linkage 1
Stack based linkage
– Advantages
Permits subroutines to call others.
Allows a larger number of parameters to be passed.
Permits records and arrays to be passed by value copy.
Saving of registers by callee is “built-in”.
A way for callee to reserve memory for other uses is “built-in”, too.
– Disadvantages
Slower than register based
More complex protocol
– Why a stack?
CIS360
Subroutine calls and returns happen in a last-in first-out order (LIFO).
Also known as a runtime stack, parameter stack, or subroutine stack.
169
Stack-based Linkage 2
Items “saved” on the stack
in one activation record
– Parameters to the
subroutine
– Old values of registers
used in the subroutine
– Local memory variables
used in subroutine
– Return value and return
address
CIS360
Say A() calls B(), B()
calls C(), and C() calls
A()
Runtime Stack
2nd stack
frame for A
1st stack
frame for C
1st stack
frame for B
1st stack
frame for A
Expanded View
Local variables
Saved general purpose
registers
Return addresses
Return values
Parameters
170
Stack-based Linkage 3
– Stack based linkage parameter passing
convention
Startup sequence:
Caller
– Push parameters
– Push space for return value
Prologue
Epilogue
– Restore general purpose registers
– Free local variable space
– Use return address to return
Body
tl
Cleanup
Sequence
Prologue
re
– Push registers that are changed
(including return address)
– Allocate space for local variables
Startup
Sequence
Callee
ca
ll
Epilogue
Cleanup Sequence
– Pop and save returned values
– Pop parameters
CIS360
171
Stack-based Linkage 4
– Stack based parameter passing example:
Register %r14 %sp stack pointer
– Invariant: Always indicates the top of the stack (it has the
address in memory of the last item on stack, usually a word).
– Moved when items are “pushed” onto the stack.
– Due to interruptions (system interrupts (I/O) and exceptions),
values stored above %sp (at addresses less than %sp) can change
at any time! Hence, any access above %sp is unsafe!
Register %r30 %fp frame pointer
– Indicates the previous stack pointer. Activation record is from
(some subroutine-specific number of words before) the %fp to
the %sp.
– Invariant: %fp is constant within a subroutine (after prologue).
CIS360
172
Stack-based Linkage 5
– Stack based parameter passing example:
!
!
!
!
!
!
!
!
!
!
!
!
!
!
Want to implement the following subroutine (also a caller):
global_function Integer subchr (A, B, C)
Substitutes character C for all B in string A,
and returns count of changes.
// In comments, "*(A+index)" is
index = 0
count = 0
LOOP: if *(A+index)=0 go to END
if *(A+index)B go to INC
*(A+index)=C
count=count+1
INC: index=index+1
go to LOOP
END:
denoted by "ch".
// while (ch != 0) {
//
if (ch == B) {
//
ch = C;
//
count++; }
//
index++;
// }
C_m:
B_m:
A_m:
R_m:
CIS360
.data
! data section
.byte ’I’
! parameter C
.byte ’i’
! parameter B
.asciz "i will tip" ! parameter A
.align 4
.word 0
! for storing result count
173
Stack-based Linkage 6
.data
! data section
.word ’I’
! parameter C
.word ’i’
! parameter B
.asciz "i will tip"
! parameter A
.align 4
! align to word address
stack: .skip 250*4
! allocate 250 word stack
bstak:
! point to bottom of stack
R_m:
.word 0
! reserve for count
.text
! Program’s one-time initialization
start:
set bstak, %sp
! set initial stack ptr
mov %sp, %fp
! set initial frame ptr
! STARTUP SEQUENCE to call subchr()
sub %sp, 16, %sp ! move stack ptr
set A_m, %r1
! A is passed by reference
st %r1, [%sp+4]
! push address on stack
set B_m, %r1
! B is passed by value
ld [%r1], %r1
! get value of B
st %r1, [%sp+8]
! push parameter B on stack
set C_m, %r1
! C is passed by value
ld [%r1], %r1
! get value of C
st %r1, [%sp+12] ! push parameter C on stack
! SUBROUTINE CALL
call subchr
! make subroutine call
nop
! branch delay slot
! CLEANUP SEQUENCE
ld [%sp], %r1
! pop return value off stack
add %sp, 16, %sp ! pop stack
set R_m, %r2
! get address of R
st %r1, [%r2]
! store R
. . .
! the rest of the program
C_m:
B_m:
A_m:
CIS360
stack:
%sp -> Return value
addr (a)
b
c
%fp ->
174
Stack-based Linkage 7
! SUBROUTINE PROLOGUE
subchr:
sub %sp, 32, %sp
st %fp, [%sp+28]
add %sp, 32, %fp
st %r15, [%fp-8]
st %r8, [%fp-12]
…
!
!
!
!
!
!
open 8 words on stack
Save old frame pointer
old sp is new fp
save return address
Save gen. Register
Save r9-r13, omitted
! SUBROUTINE BODY
ld_reg:
ld [%fp+4], %r8
ld [%fp+8], %r9
ld [%fp+12], %r10
clr %r12
clr %r13
loop:
ldub [%r8+%r13], %r11
cmp %r11, 0x0
be done
cmp %r11, %r9
bne inc
nop
stb %r10, [%r8+%r13]
add %r12, 1, %r12
inc:
add %r13, 1, %r13
ba loop
nop
done:
st %r12, [%fp+0]
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
“pop” (load) addr of A
“pop” (load) value of B
“pop” (load) value of C
%sp ->
count
index
load a string chr
is chr=null?
then go to done
is chr<>B? (branch delay)
then go to inc
branch delay slot
change chr to C
increment count
%fp ->
increment index
do next chr
branch delay slot
“push” (store) count on stack
!
!
!
!
!
!
!
Restore r9-r13, omitted
Restore r8
get saved return address
Get old value of frame ptr
Restore stack pointer
return to caller
branch delay slot
! EPILOGUE
CIS360
…
ld [%fp-12], %r8
ld [%fp-8], %r15
ld [%fp-4], %fp
add %sp, 32, %sp
retl
nop
...
%r9
%r8
return addr
old frame ptr
Return value
addr (a)
b
c
175
Stack-based Linkage 8
General Guidelines
– Keep Startups, Cleanups, Prologues, and Epilogues
standard (but not necessarily identical); easy to cut,
paste, and modify.
– Caller: leave space for return value on the TOP of the
stack.
– Callee: always save and restore locally used registers.
– Pass data structures and arrays by reference, all others
by value (efficiency).
CIS360
176
Traps and Exceptions 1
Traps, Exceptions, and Extended Operations
– Other side of low level programming -- the interface
between applications and peripherals
– OS provides access and protocols
CIS360
177
Traps and Exceptions 2
– BIOS: Basic Input/Output System
Subroutines that control I/O
No need for you to write them as application programmer
OS interfaces application with BIOS through traps (extended
operations (XOPs))
Applications
software
BIOS
Keyboard
CIS360
Screen
Mouse
Disk
178
Traps and Exceptions 3
– Where are OS traps kept? Two approaches:
Transient monitor: traps kept in a library that is copied into the
application at link-time
Appl 1
Appl 2
Appl 3
Appl 4
OS rtns
OS rtns
OS rtns
OS rtns
Resident monitor: always keep OS in main memory;
applications share the trap routines.
Appl 1
Appl 3
Appl 5
Appl 2
Appl 4
Appl 6
OS rtns
CIS360
OS routines monitor devices. Frequently used routines kept
resident; others loaded as needed.
179
Traps and Exceptions 4
– (Assuming a res. monitor) How to find I/O routines?
Store routines in memory, and make a call to a hard address.
E.g., call 256
– When new OS is released, need to recompile all application
programs to use different addresses.
Use a dispatcher
– Dispatcher is a subroutine that takes a parameter (the trap
number). Dispatcher knows where all routines actually are in
memory, and makes the branch for you. Dispatcher subroutine
must always exist in the same location.
BIOS 1
Application
Dispatcher
BIOS 12
BIOS n
CIS360
180
Traps and Exceptions 5
Use vectored linking
– Branch table exists at a well known location. The address of
each trap subroutine is stored in the table, indexed by the trap
number.
– On RISC, usually about 4 words reserved in the table. If the trap
routine is larger than 4 words, can call the actual routine.
CIS360
100
Addr of trap 0
100
104
Addr of trap 1
116
108
Addr of trap 2
132
100+4n
Addr of trap n
100+16n
181
Traps and Exceptions 6
– Levels of privilege
Supervisor mode - can access every resource
User mode - limited access to resources
OS routines operate in supervisor mode, access is determined
by bit in PSW (processor status word).
XOP (book’s notation) can always be executed, sets privilege to
supervisor mode (ta)
RTX (book’s notation) can only be executed by the OS, and
returns privilege to user mode (rett)
– Exceptions
CIS360
Caused by invalid use of resource. E.g., divide by zero, invalid
address, illegal operation, protection violation, etc.
182
Traps and Exceptions 7
Control transferred automatically to exception handler routine.
Similar to trap or XOP transfer.
Exceptions vs. XOPs
– XOPs explicit in code, exceptions are implicit
– XOPs service request and return to application; exceptions print
message and abort (unless masked).
– Trap example: non-blocking read ta 3
CIS360
If there is nothing in the keyboard buffer, return with a
message that nothing is there. Otherwise, put the character
into register 8.
183
Traps and Exceptions 8
Status of the keyboard is kept in a memory location, as is the
(one-character) keyboard buffer. Memory mapped devices.
! ta 3 returns character if one is there, otherwise
! it returns 0x8000000 into %r8
set
0x8000000, %r8 ! set default return val
set
KbdStatus, %r1 ! KbdStatus is memory loc
ld
[%r1],
%r1
! read status (1 is ready)
andcc %r1, 1, %r1
! check status
be
rtn
! can’t read anything
set
KbdBuff, %r1
! KbdBuff is memory loc
ld
[%r1],
%r8
! get character
rtn: rett
! return to caller
CIS360
On SPARC, trap table has 256 entries. 0-127 are reserved for
exceptions and external interrupts. 128-255 are used for
XOPs. Trap table begins at address 0x0000. Each entry is 4
instructions (16 bytes) long.
184
Traps and Exceptions 9
Trap execution: ta 3
– Calculate trap address: 3 * 16 + 0x0800 = 16 * (3 + 0x080)
– Save nPC and PSW to memory
• SPARC uses register windows
• Assumes local registers are available
– Set privilege level to supervisor mode
– Update PC with trap address (and make nPC = PC + 4) (jumps to
trap table)
– Trap table has instruction ba ta3_handler
– rett
• Restores PC (from saved nPC value) and PSW (resets to user
mode)
• Returns to application program
CIS360
185
Programmed I/O 1
Programmed I/O
– Early approach: Isolated I/O
CIS360
Special instructions to do input and output, using two
operands: a register and an I/O address.
CPU puts device address on address bus, and issues an I/O
instruction to load from or store to the device.
186
Programmed I/O 2
Isolated I/O
addr bus
data bus
Memory
read/write
CPU
addr bus
data bus
I/O
read/write
CIS360
187
Memory Mapped I/O
No special I/O instructions. Treat the I/O device like a
memory address. Hardware checks to see if the memory
address is in the I/O device range, and makes the adjustment.
Use high addresses (not “real” memory) for I/O memory maps.
E.g., 0xFFFF0000 through 0xFFFFFFFF.
memory
addr bus
unused
data bus
Memory
read/write
CPU
I/O
I/O
unused
CIS360
188
Programmed I/O 3
– Advantages of each
CIS360
Memory mapped: reduced instruction set, reduced redundancy
in hardware.
Isolated: don’t have to give up memory address space on
machines with little memory
189
Programmed I/O - UARTs
UARTs
– Universal Asynchronous Receiver Transmitter
Keyboard
01101010
serial
UART
parallel
0
1
1
0 CPU
.
.
0
– Asynchronous = not on the same clock.
– Handshake coordinates communication between two
devices.
– A kind of programmed I/O.
CIS360
190
UARTs 1
UART registers
– Control: set up at init, speed,
parity, etc.
– Status: transmit empty,
receive ready, etc.
– Transmit: output data
– Receive: input data
– All four needed for bidirectional communications,
– Status/control, transmit /
receive often combined.
Why?
CIS360
Control bus
Address bus
Control Reg
Status Reg
Transmit Reg
Receive Reg
Transmit
Logic
Receive
Logic
Data bus
191
UARTs 2
FFFF 0000
Memory mapped UARTs
– Both memory and I/O “listen” to
the address bus. The appropriate
device will act based on the
addresses.
– Keyboards and Printers require
three addresses (when addresses
are not combined).
– Modems require four.
– (why?)
Address bus
Control bus
CPU
Memory
UART1
UART 1 data
FFFF 0004 UART 1 status
FFFF 0008 UART 1 control
FFFF 000C
UART 2 xmit
FFFF 0010
UART 2 recv
FFFF 0014 UART 2 status
FFFF 0018 UART 2 control
FFFF 001C
UART 3 xmit
and so on
UART2
Data bus
CIS360
192
Programmed I/O 4
Programmed I/O Characteristics:
– Used to determine if device is ready (can it be read or
written).
– Each device has a status register in addition to the data
register.
– Like previous trap example, must check status before
getting data.
– Involves polling loops.
CIS360
193
Programmed I/O – Polling
Ex.: ta 2 handler (blocking keyboard input)
ta_2_handler:
set
KbdBuff,
%r1
set
KbdStatus, %r9
wait: ld
[%r9], %r10
andcc %r10, 1, %r10
be
wait
nop
ld
[%r1], %r8
rett
!
!
!
!
!
!
!
!
get addr of kbd buffer
get addr of kbd status
get status
check if ready
loop until ready
branch delay
get data
return from trap
Are you ready?...
Are you ready
now?...
How about NOW?...
Nope ..
Not
yet..
Hang
on..
Can’t afford to wait like this. Computer is millions
of times faster than a typist. Also, multi-tasking
operating systems can’t wait.
Special purpose computers can wait. E.g.,
microwave oven controllers.
Must have a better way! Interrupts are the answer!
CIS360
194
Interrupts and DMA transfers 1
Programmed (polled) I/O used busy waiting.
– Advantages: simpler hardware
– Disadvantages: wastes time
Interrupts (IRQs on PCs)
– I/O device “requests” service from CPU.
– CPU can execute program code until interrupted.
Solves busy waiting problems.
– Interrupt handlers are run (like traps) whenever an
interrupt occurs. Current application program is
suspended.
CIS360
195
Interrupts and DMA transfers 2
Servicing
an interrupt
– I/O controller generates interrupt,
sets request line “high”.
– CPU detects interrupt at
beginning of fetch/execute cycle
(for interrupts “between”
instructions).
– CPU saves state of running
program, invokes intrpt. handler.
– Handler services request; sets the
request line “low”.
– Control is returned to the
application program.
CIS360
Application
Program
:
:
*Interrupt
Detected*
:
:
Interrupt
Handler
Service
Request
:
:
Clear
Interrupt
196
Interrupts and DMA transfers 3
Changes to fetch/execute cycle
Problems
– Requires additional hardware in
Timing & Control.
– Queuing of interrupts
– Interrupting an interrupt handler
(solution: priorities and maskable
interrupts)
– Interrupts that must be serviced
within an instruction
– How to find address of interrupt
handler
CIS360
Y
Interrupt
Pending?
N
Save PC
Save PSW
PSW=new PSW
PC=handler_addr
PC -> bus
load MAR
INC to PC
load PC
197
Interrupts and DMA transfers 4
Example:
interrupt driven string output
– Want to print a string without busy waiting.
– Want to return to the application as fast as
possible
I’m
ready!
CIS360
198
Trap handler implementation
Install trap handler into trap table
– Buffer is like circular queue
– only outputs, at most, one character
disp_buf: .skip 256
disp_frnt: .byte 0
disp_bck: .byte 0
! buffers string to print
! offset to front of queue
! offset to back of queue
ta_6_handler:
! Copy str from mem[%r8] to mem[disp_buf+disp_bck]
! Disp_back = (disp_back+len(str)) mod 256
! If display is ready
!
If first char is not null, then output it
!
Disp_frnt = (disp_frnt+1) mod 256
rett
! Return from trap
CIS360
Disp_buf:
disp_frnt
Oldest
byte
Undisplayed
byte
newest
byte
disp_bck
199
Interrupt handler implementation
This too outputs only one character at most, but when display becomes
ready again, it generates another interrupt which invokes this routine!
display_IRQ_handler:
! Save any registers used
! If disp_frnt != disp_bck (queue is not empty)
!
Get char at mem[disp_frnt]
!
If char is not null, then output it
!
Disp_frnt = (disp_frnt+1) mod 256
! Restore registers and set the request line “low”
rett
! Return from trap
I’m
ready!
Uses the UART for transmission.
CPU
Memory
CIS360
200
Interrupts and DMA transfers 5
Problems with interrupt driven I/O
CPU is involved with each interrupt
Each interrupt corresponds to transfer of a single byte
Lots of overhead for large amounts of data (blocks of 512 bytes)
Execute 10s or 100s
of instructions per byte
Memory
Transfer one
word of data
CIS360
CPU
Device
Controller
Interrupt
Transfer one byte of data
201
Interrupts and DMA transfers 6
DMA (Direct Memory Access)
Want I/O without CPU intervention
Want larger than one byte data transfers
Solution: add a new device that can talk to both I/O devices
and memory without the CPU; a “specialized” CPU strictly for
data transfers.
CPU
Device
Controller
Memory
DMA
Controller
CIS360
202
Interrupts and DMA transfers 7
Steps to a DMA transfer
– CPU specifies a memory address, the operation
(read/write), byte count, and disk block location to the
DMA controller (or specify other I/O device).
– DMA controller initiates the I/O, and transfers the data
to/from memory directly
– DMA controller interrupts the CPU when the entire
block transfer is completed.
Problem
– Conflicts accessing memory. Can either arbitrate
access or get a more expensive dual ported memory
system.
CIS360