Transcript SARs - ITU
Challenges of Mobile Phone SAR
Enforcement in Africa
Dr. Ally Y. Simba
Tanzania Communications Regulatory
Authority
Introduction
Many people want to know:
Are mobile phones safe?
Are base station safe?
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
2
EMF Exposure Safety
General Conclusion of Expert Scientific Reviews
According to International guidelines, the only
scientifically established adverse health effect
of RF energy in the human body is thermal, and
its safety limits are given based on Specific
Absorption Rates (SARs)
No credible evidence that RF exposure within
Internationally accepted limits causes any adverse
health effects
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
3
SAR Basics
Specific Absorption Rate (SAR)
is the rate at which RF energy is absorbed per
unit mass of a biological body
where , are conductivity and density
| Et | 2
SAR
[W/kg] of the material, respectively and Et is the
total electric field in a biological body
SAR and Temperature Relationship
Pennes bio-heat equation
Here T represents the temperature of the tissue in degrees Celsius, ρ is the material
density (kg/m3), c is the heat capacity (J/kg/oC), k is the thermal conductivity
(W/m/°C), w is the perfusion by blood (mL/g/s), and Qm is the heat generated by
metabolism(W/m3). The term Tcore represents the core, or arterial, temperature of the
body.
SAR Basics
SAR depends on the following
Incident field parameters
- frequency, intensity, polarization
source-object configuration (near- or
far-field)
Characteristics of the exposed body
- size, internal and external geometry
electrical properties of various tissues
Ground effects and reflector effects of the
objects in the field near the exposed body
Averaged SAR
SAR is usually averaged over a certain
weight
10-g Averaged SAR
Whole
Body Averaged SAR (WBA-SAR)
14:23
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
5
Mobile SAR Limits According
to ICNIRP Guideline
Localized Exposure
Mobile phone exposure is categorise as localized
exposure, i.e., only part of the body is exposed during
use
The safety limit of the localized exposure, according to
ICNIRP is given:
General Public:
10-g averaged SAR = 2 W/kg
Occupational:
10-g averaged SAR = 10 W/kg
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
6
Mobile SAR Limits According
to ICNIRP Guideline
The limits were obtained based on the eye
experiment
– Human eye is about 10-g
– Because of the lack of blood flow in the eye,
there is low heat dissipation
– Considered to be a part that is most affected
in body
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
7
Mobile Phone SAR Enforcement
Mobile phone manufacturers are required to
ensure that their phones comply with these
objective limits for safe exposure
Manufactured phones, before put in to market
they must under go a compliance test
Phone considered safe to be legally sold in the
US and EU have FCC ID and EC mark in the
phone case, usually below the battery
The SAR values of mobile phones are available
on the internet or you can find them on the
specification sheet when you buy it
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
8
SAR Enforcement in Africa
Enforcement base on manufacturer
compliance test and FCC or EU marking in
the SAR the phone works fine in US, America
and other country where strong legal systems
exist, and illegal importation is almost
impossible
However, this approach is not effective in
most of the African countries
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
9
SAR Enforcement in Africa
The case of Counterfeit Phone
The cell of counterfeit phone is growing problem in Africa
These fake handsets are manufactured in a back office some
where in Asia and make their way to Africa countries
Due to this fact, manufacturer compliance test cannot be used
as an enforcement mechanism because even SAR value
indicated in these phone may be also fake
This problem has increased public anxiety to the public on
the safety of mobile phones
It should be noted here that, the SARs of counterfeit phones
do not necessarily exceed the safety limits
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
10
Possible Solution
The regulators should provide measured SAR
of phones in the market annually
This can be done by taking sample phone in
the market
Compare the SAR values in the phone manual
and measured ones
Inform the public of this information through
seminar, workshop and stake holder meeting
and by publishing them in the website for public
to access
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
11
SAR Measurements Approach I
Regulators need to build Type Approval Laboratories (TAL)
with mobile phone SAR testing capabilities
This is very expensive project, you will need at least the following
facilities and equipments. Most of these equipments are very
expensive
- EMC Chamber
- Mobile Phone Base Station Simulator
- SAR Measurement System
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
12
SAR Measurements Approach I
Taken from EMF Explained Series
For example; SAR testing System alone cost up to
€ 400,000 EU and annual cost of € 100,000 for maintenance
and calibrations depending on the number of accessories
SAR Measurements Approach I
Good news is less expensive testing system are developed.
Some of this do not required expensive industrial-sized robot like
those used in the conventional system, hence less expensive
SARA – C (Index SAR, UK)
iSAR system (SPEAG, Switzerland)
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
14
SAR Measurements Approach II
SAR measurements foreign laboratory
In this case the regulator will collect sample phones from the
market and send them to foreign country for measurements
Although the cost for SAR measurement per phone has not
been determine yet, this may be the short solution as the
regulators are building long term solution of building long term
capacity in equipment and human resource
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
15
Conclusion
The issue of mobile phone generate a lot of
anxiety to public in many African Countries
In order to minimize the public anxiety, the SAR of
of the mobile phone should be measured and the
values made available to the general public
There is no short cut in the SAR measurements in
Africa, Regulatory bodies should buy and install SAR
Measurements Systems or outsource the exercise in
foreign countries for few phones sampled in their
market so that to satisfy the public
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011
16
Thank you for your kind attention
contact: [email protected]
ITU Workshop on tackling climate change and SAR Measurement: Benin, July 19, 2011