television philips

Download Report

Transcript television philips

What’s New in DICOM 2004
Created by: Robert Horn – Agfa Healthcare
Chair DICOM WG-06 (Base Standard)
Presented by: Bas Revet – Philips
New in the 2004 DICOM
Publication

New Image Objects




New Structured Reports





Enhanced CT
Ophthalmic Photography
MPEG-2 and Visible Light (for endoscopy)
OB-Gyn Procedure, Catheterization Lab Procedure
Vascular Ultrasound Procedure, Echocardiography
Intravascular Ultrasound, Quantitative Arteriography
Breast Imaging
Media Related


April 1, 2005
USB and Flash Memory
Media Creation Services
DICOM Conference Singapore
New in DICOM 2004 (contd)

Other services




Relevant Patient Information Query
Spatial Registration
Instance Availability Notification
Used with other standards


April 1, 2005
Configuration Management
Web Access to DICOM Objects
DICOM Conference Singapore
New Structured Reports

All of these reports are designed to capture
precise measurements taken by equipment
during various diagnostic procedures.
Examples include:
– Fetal bone measurements
– Vascular flow and diameter measurements

Customized reports are defined for:
–
–
–
–
–
–
–
April 1, 2005
OB-Gyn procedures
Catheterization Lab Procedures
Vascular Ultrasound Procedures
Echocardiography
Intravascular Ultrasound (IVUS)
Quantitative Arteriography and Vasculography
Breast Imaging
DICOM Conference Singapore
Enhanced CT

CT has been enhanced in a manner very
similar to that done for MR last year.




Instead of one object per slice, use multi-frame images
Support segmenting the study into more conveniently
sized objects.
Support flexible structuring of slice descriptions and slice
parameters.
There is a CT and MR taskforce




April 1, 2005
To avoid compatibility problems in the field
To simplify the upgrade process
To help ensure that a hospital can upgrade all of their
equipment in a synchronized manner
To reduce development costs for vendors
DICOM Conference Singapore
Ophthalmic Photography

Supports the many different forms of
traditional ophthalmic photography, both still
and moving, with and without contrast.
– Fundus Photography,
– Bio-microscopy (slit lamp)
– External Photography

Added generic support for describing stereo
pairs for stereo viewing. All ophthalmic
objects are potentially stereo components.
April 1, 2005
DICOM Conference Singapore
MPEG-2 and Visible Light
Video



The MPEG-2 standard for compressed video has
been added as a transfer syntax. This syntax is
presently limited to the broadcast television
parameters, not other higher resolution
configurations.
Suitable for replacing videotape capture from
standard television cameras.
Defined a generic endoscopy object that supports
this transfer syntax. This object is expected to be
used as a functional replacement for the present
video camera and video tape used during endoscopic
procedures.
April 1, 2005
DICOM Conference Singapore
Media Related Additions

USB and Flash removable media




Generic removable USB devices.
Compact Flash
SD Flash
Media Creation Services

April 1, 2005
Similar to Print Services, but used to create
CD’s and DVD’s.
DICOM Conference Singapore
Relevant Patient Information
Query
Simple Interface to HIS or other
services for important patient
information such as allergies.
 Intended for use in modalities and other
equipment that is already DICOM
enabled.

April 1, 2005
DICOM Conference Singapore
Spatial Registration

Defines spatial relationships between
multiple DICOM image objects. E.g.:



Mapping PET and CT images to a common
coordinate system.
Mapping MR and CT images to a common
coordinate system.
Captures fiducial marker information:


April 1, 2005
Location of fiducial marks on images
Matching of fiducial marks between images
DICOM Conference Singapore
Instance Availability
Notification



Used by PACS, RIS, and other systems to coordinate
scheduling of activity with the transfer of image data
between systems.
Recipient of images will notify other systems after
image data transfer is complete.
Prior DICOM messages had a way for a modality to
notify the managing system that it was sending
images to the archive, but lacked a way for the
archive to indicate that all the images had arrived.
The result was excessive queries by workstations
asking the archive whether images had arrived yet.
April 1, 2005
DICOM Conference Singapore
Configuration Management



Defines proper use of DNS, DHCP, and NTP for
automatic assignment of IP addresses and automatic
maintenance of correct time.
Defines an LDAP information structure that describes
the DICOM application configuration for a network.
This is different from the other extensions in that it is
intended to improve administration and network
operations.





April 1, 2005
Quicker installation, maintenance, and upgrades
Easier reconfiguration of networks and facilities
More potential for customer performed maintenance
More potential for automatic and semi-automatic new
equipment installation.
Consistent time on images, reports, and user displays on all
systems.
DICOM Conference Singapore
Web Access to DICOM
Objects

This is a joint effort together with ISO and is
issued as both part of DICOM and an ISO
standard
 A URL format is defined so that a web query
from a web browser can be supported by a
DICOM aware server. URL parameters
indicate the desired patient, study, image,
frame, and area of the frame that is to be
returned as a JPEG image.
 Similar URL parameters are defined for some
other operations on DICOM information.
April 1, 2005
DICOM Conference Singapore
Work with other standards

HL7 CDA references from DICOM
 DICOM SR extensions to ease transcoding to
CDA
 Encapsulation of PDF Objects
April 1, 2005
DICOM Conference Singapore