CS Marketing Group, LLC
CS-100 (Cardio Scan 100)
An Acquisition and FCG (Frequency
Cardiograph) Spectrum Diagnostic System
A Preliminary Screening Tool
To Detect Coronary Artery Diseases (CAD)
Early Ischemia to Myocardial Infarction
presentation
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
2
Cardiovascular Disease
The #1 killer and cause of disability in the world
- 1 million deaths in the U.S. and 17 million worldwide every year.
- Debilitates more than 5 million every year.
Approximately 23% of myocardial infarctions go undetected.
- #1 cause of sudden death
- Irreversible debilitating condition
Over $30 billion in payments were made to Medicare beneficiaries for hospital
expenses.
CS-100 meets the need for a risk free and cost effective screening tool to detect
ischemic heart diseases in its early stage.
- Preventive screening tool for primary care physicians
- Detect ischemic condition that is reversible by exercise and dietary change
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
3
CS-100 RESEARCH AND DEVELOPMENT
A Different Approach
- More than 30 years research and development.
- Heart is a dual functioning machine – electric generator and pump.
- Change in heart’s physiology will cause change in EKG waveform.
- Apply Digital Signal Processing Principles in digitizing and transforming 12 lead
ECG into frequency components of energy value (uV) at frequency (Hz).
- Use differential diagnosis to identify and select diagnostic indexes.
- Statistically compare the value of each index against the value from the
data base to determine abnormal (+) or normal (-) for each diagnostic index.
- From (+) indexes to detect ischemic condition from early ischemia to myocardial
infarction.
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
4
Schematic Flow Chart of CS-100
Electrodes
Time Domain Cardiac
Electrical Currents
FFT (Fast Fourier
Transformation)
Into Frequency
Components
ECG
Electrocardiogram
Complied and
Recorded
Digital Signal Analysis
(1) Power Spectrum
(2) Phase Shift
(3) Impulse Response
FCG
Frequency Cardiograph
and
Diagnostic Indexes
Index Value
- Data Base
(30,000 tests)
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
5
COMPARISON OF TESTS TO DIAGNOSE HEART DISEASES
Test
Risk
Test
Time
20 min.
Average
Cost/Test
$300
Accuracy
Limitation
50-70%
High false reading for
abnormal ECG
Stress Test
Moderate
Chemical
Stress Test
Moderate
4 hours.
$3,800
80-90%
Higher false positive if
hypertensive
Angiogram
High
8 hours.
$10,000
95-98%
Highly invasive, expensive
CS-100
None
12 min.
$2,000
94-97%
Accuracy is similar to
heart catheterization, noninvasive.
* The expensive and non-routinely used Ultra-Fast CT Scan & PET technology are not included for comparison.
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
6
CS - 100
ADVANTAGES & BENEFITS
- Non-Invasive (No Injection or catheters required)
- No Strenuous Exercise Required (Patient is at rest)
- Safe and Easy to Operate
- On-site Diagnosis for CAD in 12 minutes
- High Sensitivity
- High Specificity
- Limited Training Required
- Cost Efficient
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
7
What the Experts Say:
“This technology (cardio spectrum diagnostic system) is a signature new method
of early Screening for heart diseases. It is --- a very simple, fast, and non-invasive
method ----- and should be used in clinics where cardiac screening is performed,
as well as by primary care physicians.”
William J. Tenet, M.D., New York Hospital – Medical Center of Queens
“This technology (cardio spectrum diagnostic system) will provide a significant
new method of early diagnosis of heart diseases.”
Marne Def. Gomes, M.D., Dean of Institute of Cardiology, Foundation University of Cardiology – Brazil
“Frequency Domain FCG may index LVH with a high accuracy and the prediction of
MID is largely superior (based on F statistics) to standard time-domain ECG
parameters, either taking voltage alone or time-voltage integral into consideration.
It may thus be a new tool to help indexing the probabilistic presentation of LVH.”
Paolo Emilio Puddu, Institute of Heart and Great Vessels, Ls Sapienza University, Rome, Italy
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
8
CS – 100 Opening Page
FCG Spectrum Analysis
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
9
CS-100 Important Features
- This device complies with the accepted specifications to provide the maximum
safety to patients and operators.
-
A Window based touch screen diagnostic system with an easy to operate menu.
-
Acquire 10 leads ECG signal simultaneously and continuously for up to one
hundred and ten seconds.
- Two ECG time-domain waveform display (6x2 and 12x1).
-
Frequency Analysis with CS-100 spectrum displays.
-
Five power spectrum diagnostic indexes for each of the 12 leads.
-- Five special diagnostic indexes for Lead II and V5.
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
10
ECG (Electrocardiograph)
-
CS-100 has the ECG data acquisition capability to acquire and record a
conventional 12 lead ECG simultaneously; and
-
to display and print out the ECG graph in two different formats: 12x1 and 6x2
12x1 ECG Wave Display
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
11
- Also can display and print out a 6 x 2 ECG
6 x 2 ECG Wave Display
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
12
FCG (Frequency Cardiogram)
Unique and Valuable System
- An Innovative and scientifically proven system.
- High degree of sensitivity and accuracy.
- Cardiac screening for early diagnosis of heart
disease.
- Preventive warning for reversible ischemia.
may
problems.
7/21/2015
- Detection of ischemic myocardium injuries which
eventually lead to more serious heart
Copyright, Trigon Medical Devices
Inc. 2011
13
FCG (Frequency Cardiogram)
Advanced Technology
-
Automatically amplify, filter and digitize the 12 lead cardio-electrical signals;
Transform those digitized signals into 12 individual frequency domain spectra;
Calculate and Determine (+) or (-) for each diagnostic index;
Frequency range from 0 Hz to 25.6 Hz with much refine 0.2 Hz resolution
Display and Print-out
- one page of power spectra with 60 diagnostic indexes (one power spectrum
with 5 indexes for each of the 12 lead);
- a multi-color CAD location picture, and
- frequency graph for power spectrum, phase angle shift and impulse response
and their respective diagnostic indexes for lead II and V.
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
14
C. FCG Power Spectrum
- CS-100 displays and prints out a power spectrum with all 12 leads on
- Each power spectrum lists five (5) ischemic diagnostic indexes
12-Lead FCG Power Spectra with Ischemic Diagnostic Indexes
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
15
12 LEAD POWER
SPECTRUM
can detect
of blood
-
Insufficient myocardial energy caused by lack
supply (Early Ischemia)
Myocardium injuries
- Ventricular hypertrophy or Ischemic
Cardiomyopathy
-
Myocardial Ischemia
- Myocardial compensation has set in for one or
more years
7/21/2015
CAD and its location
Copyright, Trigon Medical Devices
Inc. 2011
16
E. Two Lead Analysis:
- analyze the digitized data from the two leads (V5 and II) to determine the (+) or
(-) for one diagnostic index designated for phase shift and five (5) indexes for
impulse response; and
- Display and print out a two-lead frequency graph showing two power spectra
(one for lead II and one for lead V5, one phase shift and one impulse response.
FCG Power Spectra for Lead II and Lead V5, and Their Phase Shift
and Impulse Response
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
17
Two Lead Analysis can detect:
- Poor blood flow to the heart, poor blood circulation and
change of blood dynamics.
- Poor or defective conduction function, unstable cardiac
electricity.
- Left bundle branch conduction block.
- CAD , coronary artery blockage, or myocardial infarction
(MI). latent cardiac electrical activities at the beginning of
- Unstable
contraction.
7/21/2015
Copyright, Trigon Medical Devices
Inc. 2011
18
For More Information Contact: