KX-TDA200/100 System (Ver.1.0)

Download Report

Transcript KX-TDA200/100 System (Ver.1.0)

KX-TDA200/100 System
(Production Version 2.02)
Chapter 1
System Capacity and
System Resources
Panasonic Communications Co., Ltd.
Office Network Company
Edition 1.0 31 May, 2006
Confidential
1
Index
1. System Capacity
2. System Resources
Confidential
2
Function
1. System Capacity
Confidential
3
1.System Capacity(1/14)
Full free slot for TDA100/200
< Card (1/3) >
Line Type
Trunk
Extension
Total
Confidential
OLD
NEW (Ver.3)
TDA100 TDA200
4
4
5
8
8
10
Line Type
Trunk
Extension
Total
TDA100 TDA200
6
6
6
8
8
11
free slots 1 to 10
free slots 1 to 11
free slots 1 to 5
free slots 1 to 6
4
1.System Capacity(2/14)
Card Type
Maximum Number
KX-TDA100
KX-TDA200
LCOT / DID /
E&M / BRI
6
8
T1 / E1 / PRI
4
IP-GW
Terminal
Equipment Type
KX-TDA100
KX-TDA200
W/O MEC
W/I MEC
W/O MEC
W/I MEC
EXT
64
160
128
256
SLT
64
96
128
128
4
T76 DPT
64
128
128
256
4
4
T7560/65 DPT
64
96
128
128
DHLC / DLC /
SLC / IP-EXT
6
8
Other DPT
32
32
128
128
CSIF
4
4
APT
24
24
64
64
CTI-Link
1
1
IP-PT
64
96
128
128
MEC
1
1
RMT
1
1
OPB3
4
4
PSU-S
64
x
PSU-M
PSU-L
Confidential
128
x
512
DSS Console
8
8
CS
32
32
PS
128
128
VM
2
2
Door phone
16
16
Door opener
16
16
Ext. Sensor
16
16
Ext. Relay
16
16
5
1. System Capacity(3/14)
< Card (2/3)>
TDA100
Card Type
PRI, E1, T1, IPGW, CSIF
New
Old
Max. 4
Max. 2
Max. 2 cards for
PRI/E1/T1/IPGW/CSIF
Max. 4 cards for
PRI/E1/T1/IPGW/CSIF
New
Confidential
Old
6
1. System Capacity(4/14)
< Card (3/3)>
TDA30
Card Type
New
Old
E1
Yes
No
Confidential
7
1.System Capacity(5/14)
< Port >
TDA100
w/o MEC(1/2)
KX-TDA100
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
32
32
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
TDA100
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
N/A
N/A
N/A
N/A
N/A
DLC16
DLC16
LCOT16
LCOT16
LCOT16
LCOT16
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 64
PSU Type :
Total PT+SLT : 64
MEC Card :
Power-S
Not Required
Total:64+64=128
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
8
1.System Capacity(6/14)
< Port >
TDA100
w/o MEC(2/2)
KX-TDA100
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
32
32
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
TDA100
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
N/A
N/A
N/A
N/A
N/A
DLC16
DLC16
PRI
PRI
PRI
PRI
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 64
PSU Type :
Total PT+SLT : 64
MEC Card :
Power-S
Not Required
Total:64+120=184
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
9
1.System Capacity(7/14)
< Port >
TDA200
w/o MEC(1/2)
KX-TDA200
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
64
64
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
TDA200
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot10
Slot11
DLC16
DLC16
DLC16
DLC16
LCOT16
LCOT16
LCOT16
LCOT16
LCOT16
LCOT16
LCOT16
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128
PSU Type :
Total PT+SLT : 128
MEC Card :
Power-M
Not Required
Total:128+112=240
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
10
1.System Capacity(8/14)
< Port >
TDA200
w/o MEC(1/2)
KX-TDA200
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
64
64
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
TDA200
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot10
Slot11
DLC16
DLC16
DLC16
DLC16
PRI
PRI
PRI
PRI
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128
PSU Type :
Total PT+SLT : 128
MEC Card :
Power-M
Not Required
Total:128+120=248
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
11
1.System Capacity(9/14)
< Port >
TDA100
with MEC(1/4)
KX-TDA100
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
64
64
0
0
0
0
0
0
32
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
N/A
N/A
N/A
N/A
N/A
TDA100
DLC16
DLC16
DLC16
DLC16
IP-EXT16
IP-EXT16
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128
PSU Type :
Power-M
Total PT+SLT : 160
MEC Card :
Required
Total:160+0=160
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
12
1.System Capacity(10/14)
< Port >
TDA100
with MEC(2/4)
KX-TDA100
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
64
64
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
N/A
N/A
N/A
N/A
N/A
TDA100
DLC16
DLC16
DLC16
DLC16
LCOT8/16
LCOT8/16
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128
PSU Type :
Power-M
Total PT+SLT : 128
MEC Card :
Required
Total:128+32=160
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
13
1.System Capacity(11/14)
< Port >
TDA100
with MEC(3/4)
KX-TDA100
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
64
64
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
N/A
N/A
N/A
N/A
N/A
TDA100
DLC16
DLC16
DLC16
DLC16
PRI
PRI
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128
PSU Type :
Power-M
Total PT+SLT : 128
MEC Card :
Required
Total:128+60=188
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
14
1.System Capacity(12/14)
< Port >
TDA100
with MEC(4/4)
KX-TDA100
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
32
32
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
TDA100
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
N/A
N/A
N/A
N/A
N/A
DLC16
DLC16
PRI
PRI
PRI
PRI
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 64
PSU Type :
Total PT+SLT : 64
MEC Card :
Power-S
Not Required
Total:64+120=184
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
15
1.System Capacity(13/14)
< Port >
TDA200
with MEC(1/2)
KX-TDA200
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
128
128
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot10
Slot11
TDA200
DLC16
DLC16
DLC16
DLC16
DLC16
DLC16
DLC16
DLC16
LCOT
LCOT
LCOT
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 256
PSU Type :
Power-L
Total PT+SLT : 256
MEC Card :
Required
Total:256+48=304
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
16
1.System Capacity(14/14)
< Port >
TDA200
with MEC(2/2)
KX-TDA200
Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS
KX-T76xx DPT
KX-T76xx DPT (D-XDP)
Other DPT
KX-T7640 DSS Console
Other DSS Console
APT
Cell Station for DLC/DHLC card
Cell Station for CSI/F card
IP-PT *
SLT *
128
128
0
0
0
0
0
0
0
0
Total Port Number of KX-TV (DPT Integration)
First VM Unit
0 CH
0
Second VM Unit
0 CH
0
PBX Selection
Main Unit
Card Installation
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Slot 8
Slot 9
Slot10
Slot11
TDA200
DLC16
DLC16
DLC16
DLC16
DLC16
DLC16
DLC16
DLC16
PRI
PRI
PRI
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 256
PSU Type :
Power-L
Total PT+SLT : 256
MEC Card :
Required
Total:256+90=346
Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.
Power-M supports up to 128 points. Power-S supports up to 64 points.
Confidential
17
Function
2. System resource
Confidential
18
2.System Resources (1/4)
TDA100/TDA200
Resources
New
Old
Network DSS Key(TDA0920)
250
32
80 (4 digits)
80(4digits)+4,000(8digits)
128
80 (4 digits)
80 (4 digits)
64
32
Quick Dial
Quick Dial with MEC card
ICD Group
ICD Group Member
ICDG Member(sales C mode)
32
128
TDA30
Quick Dial with MEC card
Confidential
80(4digits)+1,000(8digits)
80 (4 digits)
19
2.System Resources (2/4)
TDA0920
is required.
Network DSS Key
Network Data Transfer
NDSS Key Table
Network PBX ID
up to 8
NDSS
up to 250
Confidential
20
2.System Resources (3/4)
Quick Dial expansion
Quick Dial
With MEC
Basic Memory
MEC Memory
Up to 80 without
MEC
Up to 4,000
with MEC
Confidential
21
2.System Resources (4/4)
ICD Group expansion
Sales
Company
Level
Miscellaneous
Enable 128
extensions
ICD Group
ICD Group Member
128 ICD groups
128 extensions
Confidential
22
Chapter 1
System Capacity and
System Resources
Thank you very much !
Confidential
23