Treat Here - ecogreentreatment.com

Download Report

Transcript Treat Here - ecogreentreatment.com

Bio Organic Catalyst Case
Study
Hydrogen Sulfide Control
In Sewer Systems
Hydrogen Sulfide Control Case
Study
1st Manhole
Poor Slope
2nd Manhole
Force Main
Flow
Lift Station
Hydrogen Sulfide Control Case
Study
Some odor here
Most odor here
Minor odor
here
1st Manhole
Poor Slope
Force Main
2nd Manhole
Flow
Lift Station
Hydrogen Sulfide Control
Case Study
Some odor here
Minor odor
Most odor here
here
1st Manhole
Poor Slope
2nd Manhole
Force Main
Flow
Lift Station
Treated here
Problem Here
(in blue)
Hydrogen Sulfide ControlBOC Injection Method
Dilution Unit
Pump
Water
BOC's
Existing Blower
Dripped not sprayed Electrically coupled to pump
Inlet
air
Lift
Pump
Existing Wet Well
Hydrogen Sulfide Control
Case Study
Monitored
here
2nd Manhole
Flow
Lift Station
Treated here
HYDROGEN SULFIDE GAS CONCENTRATION
Municipal Sewer Lift Station
(30 - minute intervals)
Treated With BOC
40
Concentration (ppmv)
Untreated
Untreated
30
20
10
0
0
24
48
72
Elapsed Time (hours)
Treated
96
120
Results of Hydrogen Sulfide
Control Case Study
Radical change in H2S gas.
Peak H2S reduced from 40 PPM to
8 PPM.
Most H2S after treatment was 0
PPM.
Results lasted several days after
test.
Very inexpensive installation.
The Power In
Nature
The Safe, Bio-Organic Catalyst for the
Future
Inside a Gravity Sewer Pipe
Pipe
Airspace
Sewer
Water
Inside a Gravity Sewer Pipe
Bacteria form
inside the pipe
Inside a Gravity Sewer Pipe
Bacteria form
inside the pipe
Oxygen is limited
A Protective
slime builds up
over the bacteria
Inside a Gravity Sewer Pipe
The bacteria
become
predominately
Anaerobic
The slime prevents
oxygen from
getting to
the bacteria
O2
Inside a Gravity Sewer Pipe
At the same time . . .
Oxygen in the sewer
water is depleted
The entire sewer
becomes anaerobic
and compounds
are reduced. . .
forming odors
Sulfates
Inside a Gravity Sewer Pipe
At the same time . . .
Oxygen in the sewer
water is depleted
The entire sewer
becomes anaerobic
and compounds
are reduced. . .
forming odors
Sulfates
+
Sulfides
Inside a Gravity Sewer Pipe
At the same time . . .
Oxygen in the sewer
water is depleted
The entire sewer
becomes anaerobic
and compounds
are reduced. . .
forming odors
Sulfides
+
Hydrogen
Inside a Gravity Sewer Pipe
At the same time . . .
Oxygen in the sewer
water is depleted
The entire sewer
becomes anaerobic
and compounds
are reduced. . .
forming odors
H2S Gas forms
Inside a Gravity Sewer Pipe
H2S gas is also very
corrosive . . . .
Pipes are destroyed
H2S Gas forms
Inside a Gravity Sewer Pipe
Slime and grease
continue to build
on the pipe
Flow is reduced
Slime builds
Treated With BOC's
Treated With BOC's
The protective slime
layer is reduced
Treated With BOC's
The protective slime
layer is reduced
Microbubbles
add oxygen to
the sewer
Exposing anaerobic
bacteria to oxygen
Treated With BOC's
The entire sewer
becomes more
aerobic . . .
Corrosion stops
Odors are prevented
from forming in
aerobic conditions
Treated With BOC's
With continued use
the pipe becomes
cleaner . . .
Preventing
corrosion
Reducing the
possibility of sudden
odor blooms
Increasing
flow
Treated With BOC's
The entire process
happens slowly,
naturally
But lasts for several
days after stopping
Injection
Where are BOC's added
to the sewer?
BOC's are normally added upstream of
where odor is perceived.
Typical Sewer Odor Problem
WWTP
Flow
Typical Sewer Odor Problem
WWTP
Gravity Main
Force Main
Gravity Main
Flow
Street Manhole
Lift Station
Main
Lift
Station
Typical Sewer Odor Problem
WWTP
Flow
Odor
Here
Typical Sewer Odor Problem
Odor
Here
Flow
Problem
Here
(Treat Here)
Typical Sewer Odor Problem
Odor
Here
Flow
Typical Sewer Odor Problem
Odor
Here
Problem Here
(Treat Here)
Flow
Typical Sewer Odor Problem
Odor
Here
Flow
Typical Sewer Odor Problem
Odor
Here
Flow
Problem
Here
(Treat Here)
Typical Sewer Odor Problem
But not
here
Flow
Odor
Here
Typical Sewer Odor Problem
But not
here
Odor
Here
(Treat Here)
Flow
Problem Here
Typical Sewer Odor Problem
But not
here
Flow
Odor
Here
Odor
Here
Typical Sewer Odor Problem
Treat
here
Odor
Odorand
Here
Here
Problem Here
Flow
INJECTING BOC'S
Injecting BOC's into the sewer is
simple and inexpensive.
INJECTING BOC's INTO
A GRAVITY SEWER
Using any sewer
manhole . . .
BOC's are dripped
into the gravity sewer
INJECTING BOC's AT A LIFT
STATION
General Layout
Dilution Unit
BOC's
Spray Injection
Pump
Water
Blower
Option
Sprayhead
Inlet
air
Wet Well
Lift
Pump
Needed in
some cases
When sprayed on the surface
of the lift station . . .
Grease does not build up on the surface of the wet well.
Odor is reduced at the lift station and downstream.
Lift station walls and equipment are kept clean.
Corrosion is halted.
Flow increases
The Power In
Nature
The Safe, Bio-Organic Catalyst for the Future
Using BOC's in
Domestic Sewage
Applications
Using BOC's in
Domestic Sewage Applications
Lagoons
Packaged Plants
Wastewater Treatment Plants
Packaged Plant Application
Typical below ground unit
Packaged Plant Application
Inlet
Final
Effluent
Primary Settling Aeration Sludge Settling
Packaged Plant Application
Treated with BOC's
$
Reduced Sludge Build up
saves clean out costs
Packaged Plant Application
Treated with BOC's
No Odor
No corrosion
Better
effluent
quality
$
Reduced Sludge Build up
saves clean out costs
Improved biomass
Improved oxygen transfer