Potential Conceptual Design

Download Report

Transcript Potential Conceptual Design

Rotating Motor
Pushing hollow
cylinder
Connector
Rotating Shaver
Stent
Design Concept #1: The Stent Shaver
The stent is carried by a cylindrical tube that is design to lock onto the Stent Shaver
platform. The pushing of the hollow tube that is covered with protective material so that when
pushing against the stent, it will not damage it. The stent is push forward to the shaver and the
shaver blades shaves off the overflow drug. The shaving diameter can be adjusted to a specific
diameter.
Conceptual Design #2 Stent Driller
Drill
Stent
Stent
Holder
Open and
Closing
The stent is load into the stent holder which
does not touch the outter diameter of the stent. The stent
is uploaded by a cylindrical rod into the stent holder which
can open and close. The drill is precisely cut to fit over
the stent inner diameter. The drill will drill through the
stent and remove any overflow solution to an accuracy.
Brush Cleaner
2 type of brush
Stent Holder
Heating Rod
Cloths Cleaner
Spinner
Conceptual Design #3: Multipurpose Cleaner
The stent is held fix by the stent holder, the spinner is rotated so that the heating rod is aligned
with the stent inner diameter. The heating rod is moved forward and heat the inner diameter of the stent to
loosen the overflow drug. Then it is move backward and the spinner rotate to the brush cleaner rod. The
brush cleaner rod moves back and fourth to scrub out the solution and absorb it in the brushes.
Lastly, the spinner rotate to the cloths cleaner rod which is made to mop and clean the stent. The stent
is then reversed to clean the other side.
Stent Holder
Rotating Rod
Stent
Circular blade
Stent Lock
Conceptual Design #4: Stent Cutter
The stent is held fix by the stent holder, and is block from moving by the stent lock. The
rotating rod spins the blade with the motion of cutting and slicing while moving slowly to the left. The
circular blade slice and cut the hanging overflow drug and is move through the entire length of the stent.
It is followed by a second stent holder, as the first one leave.
Stent
Stent Holder
Filler
Rotating Rod
Linear motion
Conceptual Design #4: Stent Filler
The stent is held into place by the stent holder and the filler is situated close to the stent
Surface and it motion is linear, up and down and forward and backward. The stent filler is rotated along
with the stent holder to file the remaining surface on the stent. The filler is made with tiny blade the will
carve the overflow coating solution.