Gilian Air Sampling and Sensidyne Detector Tubes

Download Report

Transcript Gilian Air Sampling and Sensidyne Detector Tubes

Gilian Air Sampling Pumps
The World’s Most Reliable Air Sampling Equipment
Air Sampling Introduction

Air sampling pumps draw
air through collection media
for the evaluation of worker
exposure to a targeted
substance during the work
shift.

Samples are collected using
a filter cassette or sorbent
tube then later analyzed in
a lab.
Introduction to Gilian

Gilian air sampling pumps are
manufactured by Sensidyne in
Clearwater, Florida.

Product line includes personal
and area air sampling pumps
for the evaluation of worker
exposure to airborne hazards
during the work shift.
The Gilian Advantage

Proven dependability for over 35 years

Precision accuracy for reliable samples

Robust designs for use in heavy industry

Backed by a global support network

Legacy products trusted world-wide

Innovations revolutionizing air sampling
The Gilian Family
Gilian Innovation
Gilian Legacy Products
GilAir Plus

Unmatched dynamic flow range: 1 - 5000 cc/min
– Low-flow: 1 - 449 cc/min
– High-flow: 450 - 5000 cc/min

Multi-function docking station

Data logging for sampling events
and report generation and
data export

Computer interface
option for transferring
program and sample data
Unmatched Application Versatility

Samples particulates, vapors, gases,
and metal fumes

QuadModeSM air sampling technology
*** No need for external flow adapters ***
– High-flow constant flow
– High-flow constant pressure
– Low-flow constant flow
– Low-flow constant pressure

Works with all common sampling media

Outlet port for bag sampling

Multi-language capability –
English, Spanish, French, Italian,
Dutch, Portuguese, and German

Intrinsically Safe certified
Gilian 5000

Constant flow: 800-5000 cc/min

Low flow: 20-750 cc/min

High backpressure capability

Memory free NiMH battery

Programmable functionality
–
–
–
Four stage program with repeat cycling
Allows scheduled sampling or intermittent
duty cycles
Programmable delayed start

Digital live flow display

En1232 Compliant – 3rd party verified

Intuitive operation with lock-out

Intrinsically Safe certified
Gilian 800i Low Flow Pump

Meets Requirements of High
Backpressure Low-Flow
Applications

200 – 800 cc/min Flow Rate

Backpressures up to 80 inches
H2O

Ideal solution for VOC
monitoring applications using
TD tubes
– Including modified versions of
NIOSH 2549 & EPA TO-17 at
higher flow rates for improved
sensitivities
Gilian 10i High Flow Sampling Pump

4 – 10 LPM Flow Rates

Backpressure Capability
upto 50” H2O @ 4 LPM

Intrinsically Safe Certified

Built on the Proven-reliable
Gilian 5000 Platform
Gilian 12 High Flow Sampling Pump

Flow Rates from 4 – 12 LPM

Extreme Backpressure
Capability to 67” H2O @
4LPM

Ideal for Sampling Trains
Creating High Backpressure
Across the Entire Sampling
Period
– Standard Test Method for
Measurement of Respirable
Crystalline Silica in Workplace
Air by Infrared Spectrometry
Gilian GilAir-3

Constant flow: 850-3000 cc/min

Low flow: 1-750 cc/min

Rechargeable NiMH battery pack

Built-in rotameter & flow adjust

Multiple sorbent tube capability

Programmable LCD clock timer

Instant-fault function

UL listed & Intrinsically Safe certified

ATEX & CE approved
Gilian GilAir-5

Constant flow: 850-5000 cc/min

Low flow: 1-750 cc/min

Rechargeable NiMH battery pack

Built-in rotameter & flow adjust

Multiple sorbent tube capability

Programmable LCD clock timer

Instant-fault function

UL listed & Intrinsically Safe certified

ATEX & CE approved
Gilian LFS-113

Constant flow: 5-200 cc/min

Multi-tube flow: 1-350 cc/min

Elapsed time clock

Built-in sorbent tube end breaker

Multi-tube sorbent tube sampling capability

Suction and bag-fill sampling

Instant-fault functions

Battery check LEDs

Rechargeable Battery Pack

Intrinsically Safe certified
Gilian BDX-II

Flow: 500-3000 cc/min

Rechargeable NiMH battery pack

Built-in rotameter & flow adjust

Compact, lightweight, & quiet

Low-cost designed for use with
asbestos and lead sampling

Meets NIOSH 7400, 7082, 7105
and 7300 specifications
Gilian AirCon-2

Constant flow: 2-30 LPM

DC or AC Powered

Fully programmable for custom
and unattended sampling

Touchpad & LCD display

Instant fault function

Instant pressure check

Charges battery while in AC
operation
Key Air Sampling Markets

Refineries

Chemical plants

Utilities

Construction sites

Foundries

Lead & asbestos abatement
High Flow vs. Low Flow
High Flow

Personal Pump High Flow

Flow rates from 1 to 4 LPM

Examples:
Low Flow

Flow Rates from 20 to
300cc/min

Examples:
– Hydrocarbon Solvents
(Benzene)
– Chlorinated Solvents
(Methylene Chloride)
– Alcohols
– Lead
– Asbestos
– Dust

Accessories
– Filters
– Cyclones
– Impingers

Accessories
– Sorbent Tubes
– Charcoal Tubes
Constant Flow Control

Works like the cruise
control on a car

Senses when the flow
rate is trying to drop and
speeds up the pump

Maintains the flow rate at
± 5% of set flow
Multiflow Low Flow Pumps

Constant pressure control allows two to four
simultaneous samples using special manifolds

A constant low pressure level is maintained in
the connection tubing

Flow rate is controlled with a needle valve on
each tube holder
Air Sampling Media
Charcoal Tubes
Sorbent Tubes
Cyclone Samplers
Filter Cassettes
Impingers
Universal Tube Holder System
Gilian Gilibrator-2

True Primary Standard

NIST traceable

Easy Set-Up and Operation

Microprocessor Controlled

Field Portable

Low Maintenance

Alphanumeric Display

Built-in RS-232 Port

Auto Averaging of readings

Battery or AC operation
Standard Diagnostics Panel

Measures back pressure of
sample media

Tests pump with induced
back pressure

Evaluates flow
compensation system

Handles flow rates to to 5
LPM and back pressures to
40 inches of water

Available free standing or
mounted inside Gilibrator
case
The Gilian Family
Gilian Innovation
Gilian Legacy Products
www.Sensidyne.com
800-451-9444 / 727-530-3602