Asahi/America
Actuation-Electric & Pneumatic
Asahi/America
Actuation
•
•
•
•
•
•
Actuator Packages
State of the Art Design
Ability to Interface
In-House Manufacturing
Specials
Over 25 Years Experience
Asahi/America
Actuation Markets
• Water Purification
•
•
•
•
•
•
Waste Treatment
Chemical
Landfills
Aquariums
Off Shore Applications
Semiconductor
Asahi/America
Electric &Pneumatic Actuators
Series 83-Electromni
Series 94-Quartermaster
Series 92-Quartermaster Chief
Series 79- Pneumatic
Asahi/America
Actuation
Actuator Packages
(Multiturn)
(90 Pneumatic)
(90-180 Electric)
Asahi/America
Actuation
State of the Art
Castings Strength Test
Asahi/America
Actuation
Ability to Interface
Asahi/America
Actuation
In-House Manufacturing
Asahi/America
Quality Control
Asahi/America
Quality Control Actuation
Design Life 250,000 cycles minimum
Assembly Process
Parts Inspection
100% Testing
Serializing
Appearance

Asahi/America
Actuation
Electric Actuator Terminology
 Reversing/Unidirectional
 Duty Cycle
 Nema Ratings
 Switches
 Flow Control Loop
Asahi/America
Actuation
Unidirectional:
Rotates in one direction only and stops every 90 degrees
until signaled to move again.
Reversing:
Rotates clockwise to open a valve and counterclockwise to
close a valve.
Asahi/America
Actuation
Electric Actuator Design-Spur Gear
Stator
Motor
Pinion Gear
Capacitor
Gearbox
Main Output Gear
Asahi/America
Actuation
Duty Cycle
Duty Cycle is the ratio between actuator cycle time
and the “cool off” time required based on 100%
to avoid thermal cut out.
Example: 25% Duty Cycle means that the unit can
be cycled 25% of the time.
If the actuator is cycled for 1 minute continuously,
Necessary cool off time is 3 minutes.
Asahi/America
Actuation
Nema Ratings (Non Hazardous Locations)
Type 1
Type 2
Type 3
Type 3R
Type 3S
Type 4
Type 4X
Type 5
Type 6
Type 11
Type 12
Type 13
General Purpose - Indoor
Dripproof - Indoor
Dusttight, Raintight and Sleet (Ice)-Proof - Outdoor
Rainproof and Sleet (Ice)-Resistant - Outdoor
Dusttight, Raintight and Sleet (Ice)-Proof - Outdoor
Watertight and Dusttight - Indoor and Outdoor
Watertight, Dusttight and Corrosion-Resistant - Indoor and
Outdoor
Superseded by Type 12 for Control Apparatus
Submersible, Watertight, Dripproof and Sleet (Ice)Resistant - Indoor and Outdoor
Corrosion-Resistant and Dripproof - Oil-immersed - Indoor
Industrial Use - Dusttight and Dripproof - Indoor
Oiltight and Dusttight - Indoor
Asahi/America
Actuation
Nema Ratings (Hazardous Locations)
Type 7
Type 8
Type 9
Type 10
Class I, Group A, B, C, or D - Indoor Hazardous
Locations - Air-break Equipment
Class I, Group A, B, C, or D - Indoor Hazardous
Locations - Oil-Immersed Equipment
Class II, Group E, F, or G - Indoor Hazardous
Locations - Air-break Equipment
Bureau of Mines
Asahi/America
Actuation
Nema Ratings (Hazardous Location Class & Divisions)
CLASS I
GASES OR VAPORS
DIVISION 1
Hazardous vapors present
GROUP A
Acetylene
GROUP B
Hydrogen, etc.
DIVISION 2
Hazardous vapors contained but may be present
GROUP C
Ether, UDMH, ethylene,
etc.
GROUP D
Acetone, hydrocarrbons,
acetates, alcohols, etc.
Asahi/America
Actuation
Nema Ratings (Hazardous Class & Divisions)
CLASS II
DUST
DIVISION 1
Air Suspended
GROUP E
Metal: aluminum,
magnesium, etc.
DIVISION 2
Surface accumulated -non-air suspened
GROUP F
Carbon black, coal,
coke dust, etc.
GROUP G
Flour, starch, grain, and
organic food stuffs, etc.
Asahi/America
Actuation
Nema Ratings ( Hazardous Class & Divisions)
CLASS III
FIBERS
DIVISION 1
Handled, manufactured,
or used
DIVISION 2
Handled and stored
NO GROUPS
Textiles, wood,
synthetic fibers
Asahi/America
Wiring Schematic Series 92
Asahi/America
Actuation
Aluminum
316 SS
Plastic (Glass filled Polyamide)
Asahi/America
Actuation
Pneumatic Actuator Terminology
 Designs
 Double Acting (Air to Air)
 Single Acting (Spring Return)
 Switches
Asahi/America
Actuator Types
Double Acting (Air to Air):
Requires air to open and air to close.
No fail position if air supply is lost.
Spring Return (Air to Spring):
Requires air to open only, once air is exhausted
springs close the valve.
Fail position open or close if air supply is lost.
Asahi/America
Actuation
Double Piston Rack & Pinion
Namur Dimensions
Piston
Rack
Concentric
Springs
Pinion
Double O Ring Sealing
Asahi/America
Actuation-Switches
SPST
Line
Voltage
(Single Pole Single Throw)
Used for Solenoid Valves
SPDT
Line
Voltage
(Single Pole Double Throw)
Used for one Electric Actuator
A
Line
Voltage
B
DPDT
Equipment
(Double Pole Double Throw)
Used for two Electric Actuators
Asahi/America
Flow Control Loop
4-20 ma

Set Point Controller
Positioner
Actuator
Sensor
Valve