Topics
Basics of serial communication
RS-232
RS-422
RS-485
www.idc-online.com/slideshare
Technology Training that Works
Serial Communication
Data is sent and received one bit at a time over
a communication channel.
Serial ports
9 pin and 25 pin
Used to communicate with terminals and
peripheral devices
Also known as COM port, controlled by
UART
www.idc-online.com/slideshare
Technology Training that Works
Parallel Communication
8 (or 16 or 32) bits are sent and received
simultaneously
Sent over a bus comprising 8 (or 16 or 32) channels,
one for each bit.
Usually used within a device.
www.idc-online.com/slideshare
Technology Training that Works
Connector – Types
Types of serial port connectors
www.idc-online.com/slideshare
Technology Training that Works
DTE vs. DCE
Devices that use serial cables for their communication
DTE
Data Terminal Equipment
E.g. computers, printers
Transmits on Pin 2
DCE
Data Communications Equipment
E.g. modems
Transmits on Pin 3
www.idc-online.com/slideshare
Technology Training that Works
Asynchronous vs. Synchronous
Asynchronous
No clock sent
Level sync
Character transfer
Susceptible to noise
Slow
Short lengths
www.idc-online.com/slideshare
Synchronous
Clock sent
Edge sync
Packet transfer
Resistant to noise
Fast
Long distances
Technology Training that Works
Serial Communication – Keywords
Handshaking - a procedure used to check the link
between DTE & DCE before transmitting data
Baud Rate
Transmission speed
Number of bits that are actually being sent over the serial
link
Type of Cables
Modem Cable
Null Modem Cables
www.idc-online.com/slideshare
Technology Training that Works
Modem Cable
Signal Description
9-pin
DTE
25-pin
DCE
Remarks
Carrier Detect (CD)
Receive Data (RD)
1
2
8
3
From Modem
From Modem
Transmit Data (TD)
3
2
From Terminal/Computer
Data Terminal Ready (DTR)
4
20
From Terminal/Computer
Signal Ground (SG)
5
7
From Modem
Data Set Ready (DSR)
6
6
From Modem
Request to Send (RTS)
7
4
From Terminal/Computer
Clear to Send (CTS)
Ring Indicator (RI)
8
9
5
22
From Modem
From Modem
RS-232 Pinouts DB9 to DB25
www.idc-online.com/slideshare
Technology Training that Works
Null Modem Cables
Signal description
25-pin
25-pin
Signal description
Receive Data
3
2
Transmit Data
Transmit Data
2
3
Receive Data
Data Terminal Ready
20
6+8
Data Set Ready + Carrier
Detect
System Ground
7
7
System Ground
Data Set Ready + Carrier
Detect
6+8
20
Data Terminal Ready
Request to Send
4
5
Clear to Send
Clear to Send
5
4
Request to Send
Connecting 25 pin to 25 pin for Null Modem
www.idc-online.com/slideshare
Technology Training that Works
Null Modem Cables
Signal description
9-pin
9-pin
Signal description
Receive Data
2
3
Transmit Data
Transmit Data
3
2
Receive Data
Data Terminal Ready
4
6+1
Data Set Ready + Carrier
Detect
System Ground
5
5
System Ground
Data Set Ready + Carrier
Detect
6+1
4
Data Terminal Ready
Request to Send
7
8
Clear to Send
Clear to Send
8
7
Request to Send
Connecting 9 pin to 9 pin for Null modem
www.idc-online.com/slideshare
Technology Training that Works
RS-232 Standard
Specifies the method of connection of a DTE and a
DCE.
A DCE receives data from the DTE and retransmits it to
another DCE via a data communications channel such as a
telephone link.
www.idc-online.com/slideshare
Technology Training that Works
RS-232 Connections
Connection between DTE and DCE using DB-25 connectors
www.idc-online.com/slideshare
Technology Training that Works
Voltage Levels
www.idc-online.com/slideshare
Technology Training that Works
RS-232 Transmitters & Receivers
www.idc-online.com/slideshare
Technology Training that Works
Half Duplex Operational Sequence of RS 232
www.idc-online.com/slideshare
Technology Training that Works
RS-422 Interface Standard
Defines a balanced, or differential, data
communications interface
Uses two separate wires for each signal
Permits very high data rates
Minimizes problems with varying ground potentials
www.idc-online.com/slideshare
Technology Training that Works
The EIA-422 Balanced Line Driver
Connections
www.idc-online.com/slideshare
Technology Training that Works
EIA 422 Voltages vs. Real Life
EIA voltages: ±6 volts to ±2 volts
In real systems the voltage is between ±5 volts
and ±.2 volts
Often the same chips that are used for 485
systems are used for 422
Typical measured voltage is approximately ±2
volts
www.idc-online.com/slideshare
Technology Training that Works
EIA - 422 vs. Real Life
Simplex
Half or full duplex
10Mbps
Differential
10 devices
No speed defined
Differential
Point to point
www.idc-online.com/slideshare
Technology Training that Works
RS-485 Interface Standard
Most versatile EIA standard
Distances of up to 1200m
Data rates of up to 10Mbps
32 line drivers
32 line receivers
www.idc-online.com/slideshare
Technology Training that Works
RS-485
RS-485 is the most common voltage standard in use today
for multi-drop communication systems.
This is because …
It is very resistant to noise
It can send data at high speeds
And can go long distances
www.idc-online.com/slideshare
Technology Training that Works
Two-Wire Multidrop
www.idc-online.com/slideshare
Technology Training that Works
Four Wire Network
www.idc-online.com/slideshare
Technology Training that Works
DO YOU WANT TO KNOW MORE?
If you are interested in further training or
information, please visit:
http://idc-online.com/slideshare
www.idc-online.com/slideshare
Technology Training that Works