suction electrodes
Download
Report
Transcript suction electrodes
TYPES OF ELECTRODES
BY
Parmar Anjali
Singh Sweta
WHY NEEDED ?
• Normally metal paste is used to applied on skin after
cleaning in form of electrolyte paste or jelly.
• But sometimes this treatment is time consuming &
irritating due to poor quality signal & baseline drift etc.
• During long term monitoring ,the electrode-skin interface
get dries out.Therefore,many reactions in skin takes
place.
• Periodically,jelly replinishment requires,produces
discomforts.
• Types:- Airjet electrode
Capacitive type
PASTELESS ELECTRODE
Electrode
unit
cable
Current sinks
Instrumentation
amplifier
10K
R
can
LED
R
47K
10K
R
shield
shell
gnd
V
+V
gnd
PASTELESS ELECTRODE
•
•
•
•
•
•
•
•
•
•
The dia. is of integrated electrode & amplifier arrangement for pasteless
operation.
It was designed in 1979.
Here electrode & amplifier acts as an integrated unit.
Arrangement comprises of metal shell whose function are
(1)places electrode.
(2)has gnd contact.
Shell is made up of pure titanium metal measuring 30*15*7nm.
2 FETs are connected with epoxy glue in middle of shell.Their centres are 10mm
apart.
Cans have diameter of 4.5mm & made of stainless steel.
Rectangular border of shell acts as gnd & remainder of it forms shield against
interfacing radiation.
Source terminal of 2 FETs are connected to different inputs of instrumentation
amplifier.
Amplifier has a high ac input impedence (>100Mohm).
DRAWBACKS
• High electrode resistance & strong sensitivity
to motion.This resistance can be overcome by
high input resistance.
• Skin preparation required to remove motion
artefacts.
• All process are time consuming & so loses
practicability of dry electrodes for routine
clinical use.So,less acceptable to patient.
PRE-GELLED DISPOSABLE ELECTRODE
• Electrode snap contact.
• Sensor has diameter:0.5-1.5
• Ag-Agcl conductor
• Buffer layer
• Diameter of electrode:4.6cm
• Tape of polyethylene is
used
PROPERTIES OF GEL
• Moistness is due to intended shelf life by
including humectant in gel.
• Prevent micro-organism & mould growth.
• Provide low electrolyte skin impedance.
• Causes minimum skin irritation
STANDEREDS
• Direct current offset
voltage.
• Combined offset instabiliy &
internal noise.
• Alternating current
impedance.
• Defibrillation overload
recovery.
• Bias current tolerance.
ADVANTAGES
• Reduces artefacts,drift
• Baseline wandering
provides buffer layer.This
absorbs effects of
movement of electrode in
relationship to skin.
• No risk of infection.
• Small size & so easy to
handle.
• Less time required per ECG
procedure.
SUCTION
ELECTRODES
SUCTION ELECTRODES
THESE ELECTRODES ARE USED IN
ELECTROCARDIOGRAPHY AS PRECORDIAL
LEADS,AS THEY CAN BE PLACED AT A
PARTICULAR LOCATION AND USED TO TAKE
RECORDING.
THEY CONSIST OF A HOLLOW METALLIC
CYLINDRICAL ELECTRODE THAT MAKES
CONTACT WITH SKIN AT ITS BASE.
SUCTION ELECTRODE
AN APPROPRIATE
TERMINAL FOR THE
LEAD WIRE IS
ATTACHED TO THE
METAL CYLINDER,AND A
RUBBER SUCTION BULB
FITS OVER ITS BASE.
ELECTROLYTE GEL IS
PLACED OVER
CONTACTING SURFACE
OF THE ELECTRODE.
SUCTION ELECTRODE
THEN THE BULB IS
SQUEEZED,AND THE
ELECTRODE IS THEN
PLACED ON THE CHEST
WALL.
THE BULB IS RELEASED
AND APPLIES SUCTION
AGAINST THE
SKIN,HOLDING THE
ELECTRODE ASSEMBLY
IN PLACE.
DISADVANTAGES OF SUCTION
ELECTRODE
THIS ELECTRODE CAN BE USED ONLY FOR A
SHORT PERIODS OF TIME.
THE SUCTION AND THE PRESSURE OF THE
CONTACT SURFACE AGAINST THE SKIN CAN
CAUSE IRRITATION.
ALTHOUGH THE ELECTRODE ITSELF IS QUITE
LARGE THE ACTUAL CONTACTING AREA IS
RELATIVELY SMALL.
THESE ELECTRODES HAVE A HIGHER SOURCE
IMPEDANCE.
FLOATING
ELECTRODES
INTRODUCTION
LIMB ELECTRODES GENERALLY SUFFER FROM
WHAT IS KNOWN AS MOTION ARTEFACTS DUE
TO THE RELATIVE MOTION AT THE INTERFACE
BETWEEN THE METAL ELECTRODE AND THE
ADJACENT LAYER OF ELECTRODE JELLY.
THE INTERFACE CAN BE STABILISED BY THE
USE OF FLOATING ELECTRODES IN WHICH THE
METAL ELECTRODE DOES NOT MAKE DIRECT
CONTACT WITH THE SKIN.
THESE ELECTRODES CAN BE RECHARGED;THAT
IS THE JELLY IN THE ELECTRODES CAN BE
REPLENISHED IF DESIRED.
CONNECTION WITH THE INSTRUMENT CAN BE
ESTABLISHED WITH SILVER PLATED COPPER
WIRES FIXED IN CONDUCTING DHESIVES.
THESE ELECTRODES ARE EXTREMELY LIGHT
WEIGHT AND DO NOT MAKE USE OF
ELECTRODE JELLY.
FACIAL ELECTRODES
• PRECORDIAL LIMB PLACEMENT
CLAMP ELECTRODES