Sales presentation
Download
Report
Transcript Sales presentation
Compact I/O Modules
XIO Family
Sales Presentation
XIO Compact I/O Family Features
• XIO Compact I/O are distributed I/O for use
with the Honeywell XL5000 product line.
- Additional I/O for XL50 or XL500 controllers
- Easy installation via LNS Plug-in
- Small profile allows for installation in
otherwise hard to reach areas
• The XIO Compact I/O family fills out
Honeywell’s already robust distributed I/O
offering
- XIO Compact I/O
- XFL Distributed I/O
- XFC Smart I/O
2
OS Number
Applications
XIO-10DI
10 Digital Inputs
XIO-4DI
4 Digital Inputs
XIO-4DO
4 Digital Outputs
XIO-8AI
8 Analog Inputs
XIO-4NTC
4 20KΩ NTC Inputs
XIO-4PT1000
4 Platinum 1000 Inputs
XIO-4AO
4 Analog Outputs
XIO-10HUB
Hub expander module
XIO Compact I/O
The XIO Compact I/O offers these distinguishable
features:
• Easy installation
- DIN rail mounting
- Only 2 twisted pair wires for up to 15 modules.
Run 24VAC and Lon Network cable to
first module then link 14 more to the first
• Easy to expand
- Pick and chose the right number of I/O for each job.
No longer have unused I/O on the
job
• Eye-pleasing form factor
- No complex buttons or switches
• Compact
- Very small profile. Install in places other modules couldn’t fit
• Save time and money
- No need to run extra wire for 24VAC and Lon network saves labor time and wire costs
• Range of input and output types and sensors
- 8 Modules: DI, DO, AI, AO and a HUB expander module
3
Opens Up New Markets
• The XIO can help you open doors with New Contractor’s:
- Bring to any open Lon system contractor
- Use as a door opener – the XIO will already work with their
system
• Start with the XIO and come back to talk about valves
and actuators
- Once you have their attention with the XIO you have a reason to
make a second call
Valves
Actuators
Building Controls
4
Nomenclature
Family Designation
XIO = Compact I/O
Number of Inputs/Outputs
4 = 4 total inputs or outputs
8 = 8 total inputs or outputs
10 = 10 total inputs or outputs
XIO - 8AI
Input/Output Type
DI = Digital Input
DO = Digital Output
AO = Analog Output
AI = Analog Input
NTC = Specific 20KΩ NTC Analog Input
PT1000 = Specific Platinum 1000 Analog Input
HUB = Free Contacts
5
Compact I/O Modules
XIO Family
Module Descriptions
XIO-10DI
• Typical Applications
- Pump Status, Power status, Freeze Status
• LON module with 10 digital inputs
• Record the status of potential free
switches (dry contacts)
- electronic limit switches at vent valves or
auxiliary contacts at power contactors
- record counted measurands at counters with
contactor.
• Terminals 1 - 10 and the C (common) input
contacts can be connected to potential free
switches (dry contacts)
• States and counted measurands are read
out by standard network variables and
bound to XL500 or XL50 controllers
• Configuration is done by LNS® Plug-in
7
XIO-4DI
• Typical Applications
- Pump Status, Power status, Freeze Status
• LON module with 4 digital inputs
• Record the status of potential free switches (dry
contacts)
- electronic limit switches at vent valves or auxiliary
-
contacts at power contactors
record counted measurands at counters with contactor
• Terminals 1 - 4 and C (common) input contacts can
be connected to potential free switches (dry
contacts)
• States and counted measurands are read out by
standard network variables and bound to XL500 or
XL50 controllers
• Configuration is done by LNS® Plug-in
8
XIO-4DO
• Typical Applications
- Start up a remote device such as packaged boiler
exhaust fans and remote pumps
• LON module with 4 digital outputs
• Switch electrical components
- motors, contactors, lamps, blinds etc.
• Relays activated by standard network
variables
• Manual control override function that is only
activated in the "Configured Mode"
• Configuration is done by LNS® Plug-in
9
XIO-8AI
• Typical Applications
- Remote sensors such as Outdoor Air Temperature,
hot water loop temps at the end of a loop, differential
pressure that is 2/3 of the way down the system,
outside humidity, enthalpy, monitor room
temperatures using 1 XIO-8AI per floor.
• LON module with 8 configurable temperature or
voltage analog inputs
• Record temperatures and voltages of passive and
active sensors
- electrical ventilation and mixing valves, valve
positions
• Different formats can be read out depending on
the setting for each input, and bound to other
LonMark® devices
- Temperature, resistance, percentage and voltage
• Supply voltage for active sensors can be provided
by the module.
• Configuration is done by LNS® Plug-in
10
XIO-4NTC
• Typical Applications
- Same as XIO-8AI but for 20K NTC sensors only
- More accurate at the normal operating range
• LON module with 4 specific analog inputs
for 20K NTC sensors
• Inputs can be scanned simultaneously by
standard network variables, SNVT
11
XIO-4PT1000
• Typical Applications
- Same as 8AI but for PT1000 sensors only
- More accurate at extreme ranges
• LON module with 4 specific analog inputs
for Platinum 1000 sensors
• Inputs can be scanned simultaneously by
standard network variables, SNVT
12
XIO-4AO
• Typical Applications
- Control a VFD for an exhaust fan. Control for a
cooling tower fan, remote pumps, and speed
control
• LON module with 4 analog outputs
• Outputs are activated proportionally by the
network variables, SNVTs
• Provide a voltage between 0 and 10 Volts
• Outputs can be set to a previously defined
value depending on a binary state
• Manual overrides included
• Configuration is done by LNS® Plug-in
13
XIO-10HUB Extension Module
• Typical Applications
- Used primarily with XIO-10DI. See figure at
right
• Provides additional potential free
contacts as supporting contacts to
connect digital outputs, analog outputs,
etc.
• Six contacts each are interconnected.
• A maximum of 60 volts can be applied
to the contacts.
• The extension module can be used as
a power on module for bus connection,
supply voltage and potential
distribution.
14
Selling Points
• Easy installation
- Small footprint
- Easily Expandable
Link up to 15 different modules together with jumper clip. No
need for extra wire for power and network
- Lower I/O count than XFL and XFC: less unused I/O on the
job
- DIN rail mounting
15
Compact I/O Modules
XIO Family
System Setup
System Setup
• The XIO do not have processing power of their own and
must be bound to one of the following controllers
XL50
XL500 Smart
17
XL500
XL50
XL50
XIO-10HUB
XIO-10DI
Lon Bus
XIO-4AO
18
XIO-4DI
XIO-4DO
XIO-4NTC
XIO-4PT1000
XIO-8AI
XL500
XL500
XIO-10HUB
XIO-10DI
Lon Bus
XIO-4AO
19
XIO-4DI
XIO-4DO
XIO-4NTC
XIO-4PT1000
XIO-8AI
XL500 Smart
XL500 Smart
XIO-10HUB
XIO-10DI
Lon Bus
XIO-4AO
20
XIO-4DI
XIO-4DO
XIO-4NTC
XIO-4PT1000
XIO-8AI
Compact I/O Modules
XIO Family
I/O Comparison and Selection Guide
I/O Comparison
Compact I/O
XIO-4DI
Digital Inputs
Digital Outputs
Analog Inputs
4
XIO-8AI
8
XIO-4AO
4
10
XIO-4PT1000
4
XIO-4NTC
4
Digital Inputs
Digital Outputs
XFC3A06001
4
4
4
2
XFC3D06001
4
4
4
2
Digital Inputs
Digital Outputs
Distributed I/O
XFL521B
XFL524B
22
Analog Inputs
Analog Inputs
Analog Outputs
Analog Outputs
8
XFL522B
XFL523B
Compact I/O are stand alone
with one type of I/O on each
module. You do not need to
purchase separate pieces to
make a working I/O module.
Provides additional free contacts
XIO-10HUB
Smart I/O
Comments
4
XIO-4DO
XIO-10DI
Analog Outputs
8
12
6
Comments
Smart I/O are stand alone.
Unlike the Compact I/O,
the Smart I/O has multiple
types of I/O on each
module.
Comments
Compact I/O are not stand
alone. They require multiple
pieces be put together to
create a working I/O module.
Please refer to the next slide
for what to purchase to
create a complete I/O
module.
XFL Distributed I/O Selection Guide
Select the type of I/O module you wish to use in the first column. Then follow that
row to the right, anything that is marked is also needed to create a fully functional I/O
module.
XFR522A
XFR524A
XSL513
XSL514
XSL511*
Manual Override Switches
for the XFL522B
Manual Override Switches
for the XFL522B
Terminal Block for XFL521B,
XFL522B, XFL523B
Terminal Block for
XFL524B
Lon Network Interface
XFL521B
Analog Input Module
X
X*
X
X*
X
X*
XFL 522B
Analog Output Module
Optional if manual
override is desired
XFL523B
Digital Input Module
XFL524B
Digital Output Module
Optional if manual
override is desired
X
X*
*If more than one Distributed I/O module is linked together than only one XSL511 is needed for that grouping
Up to 8 distributed I/O modules can be linked to one XSL511
23
Compact I/O Modules
XIO Family
Pricing
Pricing
Compact I/O
Trade Base Price
XIO-4DI
$465
XIO-4DO
$465
XIO-8AI
$705
XIO-4AO
$505
XIO-10DI
$505
XIO-4PT1000
$490
XIO-4NTC
$490
XIO-10HUB
$75
Smart I/O
XFC3A06001
$723.84
XFC3D06001
$774.33
Distributed I/O
25
Trade Base Price
Trade Base Price
XFL521B
$484.81
XFL522B
$484.81
XFL523B
$484.81
XFL524B
$484.81
XFR522A
$192.27
XFR524A
$192.27
XSL 511
$85.44
XSL513
$161.75
XSL514
$161.75
Price Per I/O
Compact I/O
I/O Count
Trade Base Price
XIO-4DI
4
$465
$116.25
XIO-4DO
4
$465
$116.25
XIO-8AI
8
$705
$88.13
XIO-4AO
4
$505
$126.25
XIO-10DI
10
$505
$50.50
XIO-4PT1000
4
$490
$122.50
XIO-4NTC
4
$490
$122.50
XIO-10HUB
Smart I/O
Provides additional Free contacts and is not an I/O module
I/O Count
Trade Base Price
Price Per I/O
XFC3A06001
14
$723.84
$51.70
XFC3D06001
14
$774.33
$55.31
Distributed I/O
26
Price Per I/O
Trade Base Price*
I/O Count
*Price includes Subbase and Network Card
Price Per I/O
XFL521B
8
$732.00
$91.50
XFL522B
8
$732.00
$91.50
XFL523B
12
$732.00
$61.00
XFL524B
6
$732.00
$122.00
Compact I/O Modules
XIO Family
Product Launch Activities
Launch Materials
• Launch date: July 17, 2006
• Collateral
- I/O Modules Quick Selection Guide
- Compact I/O Modules Brochure
- Distributed I/O Modules Brochure
- Smart I/O Modules Brochure
- I/O Module Poster
- Postcard to Contractors
• Sample unit to sales reps and
Diamond Distributors
• Webcast to Distributors and
Contractors 7/10 (with ZonePRO
Webcast)
28
Technical Literature
INSTALLATION INSTRUCTIONS
95-7720
XIO-10DI Installation Instructions
95-7717
XIO-10HUB Installation Instructions
95-7718
XIO-4AO Installation Instructions
95-7714
XIO-4DI Installation Instructions
95-7719
XIO-4DO Installation Instructions
95-7727
XIO-4NTC Installation Instructions
95-7728
XIO-4PT1000 Installation Instructions
95-7716
XIO-8AI Installation Instructions
PRODUCT DATA (Not Currently Available)
74-4043
Product Data
95-7733
Operating Guide
PRESENTATIONS
29
Sales Presentation
The one you are currently watching
Technical Presentation
Comes with Launch Materials
Compact I/O Modules
XIO Family
Operation with WEBs
Honeywell WEBS
• Currently XIO is only available to be programmed with
CARE through LNS Plug-in.
• Workbench Wizard and .lmnl files will be introduced
shortly to configure with WEBs more easily
WEBs Controller
XIO-10HUB
XIO-10DI
Lon Bus
XIO-4AO
31
XIO-4DI
XIO-4DO
XIO-4NTC
XIO-4PT1000
XIO-8AI
www.honeywell.com