GPM Power Point Presentation
Download
Report
Transcript GPM Power Point Presentation
BayTech Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Global Power Management detects BayTech SNMP devices on the local subnet or can
be given IP’s to discover remote BayTech SNMP devices.
Once discovered a status screen displays the controllers and associated RPC’s with
their receptacles.
Automatic Discovery of BayTech SNMP Devices
Discover controllers on the same subnet, or enter the IPs of remote controllers
Status Screen for Discovered BayTech Controllers
Status screen provides a snap shot of all BayTech
power solutions. Controllers, RPC’s and Outlets
are displayed. On/Off, reboot and status funtions
are supported by a simple right click of the
mouse.
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote Locations
One of the power features of GPM is the ability to group equipment in many
ways. Whether you need to view a data center server cabinet by location or
view all your Unix servers together GPM lets you group any way you need
Build Logical Views of RPC’s in Remote Locations
Tree View shows a
logical or functional
view of a data
center. Equipment
can be grouped
any way as well as
many ways.
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power Supplies
Through an easy to use drag and drop interface you can assign device
names(servers) for single or multiple receptacles. Receptacles can be assigned from
any active controller in the Power Management Network.
A single device name can support any number of receptacle so if you want to make a
group of devices which are turned off during critical power outages you can simply
do this with the click of a button.
Power sequence can be assigned to devices with multiple receptacles. This is useful
for bringing up device power supplies in a desired sequence.
Supports Equipment with Single or Redundant
Power Supplies
Supports
redundant power
sources. Assign
multiple
receptacles to
any device.
Simply drag
discovered
receptacles
from outlet list
to device name.
Power Sequence any Supplies on any Device
GPM allows you to sequence power supplies in any order.
Delays can be set between operations.
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Simply right click on any device name with an assigned receptacle and you can turn
on/off or reboot that device. The option to remove or change the name of this device
is provided at this point.
Provides easy Click Through control of RPC’s anywhere
Simply right
click on
defined
equipment
and you
have the
option(s) to
turn on/off
or reboot the
equipment
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
GPM maintains a list of all alerts received from RPC devices being monitored. A
clicked alert will trigger GPM’s tree view to drill down to the specific devices causing
the alert.
Displays Alerts for All or Individual RPC’s
The “Alerts” view displays all SNMP traps received for
all controllers monitored by GPM. Selecting the alert
automatically navigates the user to physical location
within the organization.
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
GPM allows a user to monitoring and receive alarms based on the BayTech SNMP
mib. Emails and associated messages can be sent to individuals or groups of
individuals.
The GPM configuration provides a means to pick and choose which alerts will be
flagged for notification.
Environmental Alarm Thresholds Set per RPC
Current, voltage and temperature thresholds can be set for every circuit in your in
your data center. Based on thresholds and trap settings NOC personal can be notified
via email when circuits reach capacity.
Alerts are Customized Based on Preset Conditions
Email Alerts Sent to Single or Multiple Recipients
To: [email protected]
Subject: Global Power Management Alert !!! -- Please Review Immediately
*--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--*
Baytech Power Management Message:
Subject
Sent To
Date/Time
Controller Name
Controller Ip
Power Strip Name
Location
Outlet(s) Name
:Outlet(s) turned OFF
:[email protected],[email protected]
:20020827
:NORLINX CONTROLLER IN CABINET 1
:66.83.91.37
:BT RPC4-1001092
:Raleigh Data Center
:(1) - alexnorth008329
(2) – Server 1
(3) - Server 2
(4) - Outlet 3
(5) - Outlet 4
(6) - Outlet 5
(7) - Outlet 6
(8) - Outlet 7
(9) – Outlet 8
(10) – Outlet 9
(11) – Outlet 10
(12) - Outlet 11
(13) - Outlet 12
(14) - Outlet 13
(15) - Outlet 14
(16) - Outlet 15
*--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--**--ALERT--*
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
GPM graphically displays the circuits power environment. Prior to adding devices NOC
managers can easily check the capacity of a circuit, then make an informed decision
on whether to add more equipment.
Graphically Displays Power Environment Per RPC
Power
environment is
displayed
through
graphical and
textual displays
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
GPM graphically displays the circuits power environment. Prior to adding
devices NOC managers can easily check the capacity of a circuit, then make
an informed decision on whether to add more equipment.
Global Power Management
GPM Software for BayTech Remote Power Controllers
Discovers BayTech devices on existing subnet
Build Logical and Functional Views of RPC’s in Remote
Locations
Supports Equipment with Single or Redundant Power
Supplies
Provides easy “Click Through” control of RPC’s anywhere
Displays Alerts for All or Individual RPC’s
Notification of Alert via Email
Graphically Displays Power Environment Per RPC
Provides Graphical Reporting for any segment or
organization node.
Exposes Enterprise Security Model for Access to Power
Control
Power Utilization
See power utilization in any segment of the data center by
simply clicking the segment. For example clicking on IBM
Cabinet1 would yield combined power utilization for that
cabinet. This could be extended to the entire Raleigh segment,
again by simply clicking on Raleigh.
Power Utilization over Time
Graph power, voltage, current, max current and temperature over a
specified time interval. Great for detecting power and temperature
trends within any segment of the datacenter or organization.
Expose Enterprise Security and Control Access.
WinNT/2000
Domains
exposed to the
power
infrastructure.
Administrators
can drag users
or groups to
any level
within the
organizational
structure.
User and
groups can be
assigned
specific
operations.
WinNT/2000 Login