THE X-RAY UNIT - Montgomery College

Download Report

Transcript THE X-RAY UNIT - Montgomery College

THE X-RAY UNIT
THE BASICS
WHAT FOUR COMPONENTS ARE IN
TYPICAL RADIOGRAPHIC ROOM?
1. X-RAY TUBE
2. OPERATING CONSOLE
3. HIGH VOLTAGE GENERATOR
4. X-RAY TABLE
THE X-RAY TUBE
Chapter 7 in Bushong
• OVERHEAD
Ceiling suspension
Sets of rails-controls
longitudinal/transverse
positioning
Telescoping column
for controlling vertical
distance.
• FLOOR
Tube-support column
mounted on floor
Same positioning
options as overhead
Counter weight on
back of telescoping
column. Why?
OTHER COMPONENTS ON XRAY TUBE
•
•
•
•
•
•
•
•
Collimator light
Collimator controls
Transverse lock
Horizontal lock
Longitudinal lock
Vertical lock
Tube head lock
Tape Measure
• C-arm
• Protective housing
–
–
–
–
Isotrophically
Window
Useful beam
Leakage
• Acceptable level of leakage is….?
CHAPTER 6
What is the typical voltage range?
What is the typical current range?
X-RAY TABLE
•
•
•
•
•
•
Must be radiolucent
Can be tilted
Float
Holds bucky
Has weight limit of 300lbs(Carbon-fiber)
Easily cleaned, hard to scratch and without
crevices
X-RAY CONSOLE
• Allows the radiographer to control the x-ray
tube current (mA) and the voltage (kVp) so
that a useful image is produced.
• ? Controls the quantity
• ? Controls the quality
• What does a line voltage compensator do?
AN R/F ROOM
• Contains a radiographic unit
• Contains a fluoroscopic unit
– located under radiographic table
– used in studies where it is necessary to watch a
procedure on a monitor using x-rays.
HIGH VOLTAGE
GENERATOR
Housed within the x-ray room
Mobile radiography
mAs AND THE IMAGE ON
THE FILM Fauber pgs 60-65
•
•
•
•
What is mAs?
mAs = the mA X exposure time
mAs is the quantity of x-rays
mAs produces the overall
blackening(DENSITY) on the film
kVp and the image produced on
the film (pgs 67,80-84)
• What is kVp?
• Controls the quality or penetrating quality
of the x-ray beam
• Produces the varying shades of gray on the
film.
Anatomic part and contrast
• Range of densities
• Tissue composition
• Page 88, figure 4-19, 4-20-4-21
Intro to Digital Imaging
Fauber and Carter
•
•
•
•
•
Pg 79-80- Fauber
What are some areas to be aware of?
Carter pgs 80-82
Does KVP matter anymore?
Does mAs matter anymore?
Radiographic Qualities
• Photographic
• Allow us to see image
– Density and Contrast
• Geometric
• Produce a sharp image
– Recorded detail and
distortion
Four radiographic qualities
• Density
• Contrast
-----------------------• Fauber Chapter 5
• Recorded detail
• Distortion
• Overall blackness
• Difference between
adjacent densities
----------------------• Sharpness of the lines of
an image
• Misrepresentation of the
true size or shape of image
Controlling and influencing factors
• What might control or influence the four
radiographic qualities?
• Density
• Contrast
• Recorded detail
• Distortion
• Images 4-28,4-29, 4-30, 4,31 pg 104 Fauber
• Images 5-11, 5-15, Figure 5-16, all images on pg
130-131 Fauber
Sharpness vs. Visibility
• Driving on a foggy night (visibility)
• Driving after having drops in your eyes
(Sharpness)
Good images vs Bad images
•
•
•
•
Over exposed
Over penetrated
Poor detail
distortion
HOMEWORK
REVIEW MODULES 2 AND 3
RADIOGRAPHIC DENSITY