Generator Product Overview
Download
Report
Transcript Generator Product Overview
Engineering Presentation
by
Emergency Systems Service Company
Distributor For:
Emergency Systems
Service Company
Your Partner for
Generators – Automatic Transfer Switches- Accessories
Technical Overview
Presented by Bob Hafich
President/Sales
Emergency Systems Service Company
Emergency Systems
Service Company
Your Partner for
Located in Quakertown, Pennsylvania, 40 miles Northwest of Philadelphia.
Established in 1974 by Joseph A. Hafich, we have been proudly serving the
Delaware Valley and Lehigh Valley for over 40 years.
Emergency Systems
Service Company
Your Partner for
Emergency Systems Service Company
Specializes in the Sales, Service, Rental, Planned Maintenance
Agreements, Load Bank Testing, and Replacement Parts for
Engine-Generator Sets and Automatic Transfer Switches
Company Personnel
Robert R. Hafich – President of Sales and Administration
Joseph M. Hafich – President of Service, Operations and Engineering
Along with 38 other dedicated employees who make us one of the premier
MTU Onsite Energy generator set distributors
Emergency Systems
Service Company
Your Partner for
Emergency Systems Service Company
Service
- Employs 17 Service Technicians – Fully stocked Service Vans
- Custom Tailored Maintenance Service Agreements & Scheduled Repairs
- 24/7 Emergency response Service
- Over 800 Maintenance Agreements on over 1200 units
- We service all Manufacturers such as MTU, Katolight, Kohler, Onan,
Caterpillar, Cummins, Detroit Diesel, Asco, GE/Zenith,
Cutler Hammer.
- Resistive Load Bank Testing, over 2000kw capablility.
- JCAHO and NFPA 110 Certification Testing
Parts
- Extensive Parts Inventory for numerous Manufacturers.
- Maintenance parts, Engine Parts, Control Parts, Accessories
Emergency Systems
Service Company
Your Partner for
Rental Generators
Fleet of over 40 Mobile Generators for Rental
Applications. Sizes from 22kw to 1000kw
24/7 availability
Switchable Voltages
Diesel Engines with Base Mounted Fuel Tanks and
Rupture Basin
Sound Attenuated Enclosures. Low DBA levels
Rental Cable available in multiple sizes and lengths
Rentals available for: Daily – Weekly – Monthly and
long term
Available services include Transportation, Tie-ins.
Emergency Systems
Service Company
Your Partner for
Rental Automatic Transfer Switches
200 Amp to 1600 Amp
Switchable Voltages
Nema 3R Enclosures
Equipped with time delays, Pilot lights and Exerciser
Tie in Cable available
Transportation and cable-in service
Weekly, Monthly or Long term rates available
Emergency Systems
Service Company
Your Partner for
MTU Power Generation
Tognum acquired Katolight in April 2007
Katolight Established in 1952
Manufacturing, assembly, testing location for MTU Onsite Energy
Power Generation. Located in Mankato, MN
Emergency Systems
Service Company
Your Partner for
Generator Product Overview
Diesel – 30 KW to 3250 KW (Latest EPA Tier Certified)
Natural Gas/LP – 30 KW to 400 KW (EPA Certified)
Available Voltages
120/240 Single Phase
120/240 Three Phase
120/208 three Phase
277/480 Three Phase
Medium Voltage – 5 KV and 15 KV
Prime Movers
Diesel - 30 KW to 200 KW – John Deere
Diesel - 230 KW to 3250 KW – MTU
Natural gas – 30 KW to 125 KW GM & Ford
Natural Gas – 150 KW to 400 KW - Doosan
Generators: Marathon – Newage – Leroy Somer -
Emergency Systems
Service Company
Your Partner for
Standard and Optional Accessories
Generators
Temperature Rise – 150 degree C Standard (Optional 130, 105, 80)
Oversized Generator Ends – Better performance for non-linear loads
PMG (Permanent Magnet Generator) – Better performance for motor starting.
Cooling Systems
Standard Unit Mounted Radiator with Duct Flange
Optional Remote Radiator
Optional Heat Exchanger
Governor
Isochronous (+/- ¼% voltage and frequency regulation)
Control Panel
MGC Digital Control Panels. Level 1, Level 2 and Level 3
All NFPA 110 Level 1 Compliant
Monitors all Engine and Generator Parameters plus Safety Protection
Generator Set can be Controlled and Monitored either Locally or Remotely
Communications Capability – Open Protocol, RS232, RS485
With Available Communication Options
Modbus TCP/RTU
Load Share Module for Internet Protocols
Paralleling Capable
Emergency Systems
Service Company
Your Partner for
Standard and Optional Accessories
Remote Annunciator Panel
NFPA 110 Level 1 Compliant
2 Wire Twisted Pair Communication Cable Belden Blue Hose Number 9463
DC or AC Powered
Main Line Circuit Breakers
Unit Mounted
600V Rated
80% Rated
Thermal Magnetic Trip
Battery
Sealed Lead Acid
12 VDC or 24 VDC
Polyethylene Battery Box
Battery Cables
Emergency Systems
Service Company
Available Breaker Options:
100% Rated
Digital Electronic Trip
Ground Fault, Shunt Trip, Auxiliary Contacts
Mag Amp only (Fire Pump Applications)
Unit Mounted Multiple Breakers
Battery Charger
Full Float Battery Charging
12 VDC or 24 VDC to match battery voltage
120 VAC Input (other voltages optional)
NFPA 110 Level 1 Compliant with monitoring and alarms
Loose or factory mounted and wired. (Open Power Units)
Factory mounted and wired (Enclosed Power Units)
Your Partner for
Standard and Optional Accessories
Silencers
Critical and Hospital Grade
Flexible Exhaust Connection
Silencer and Flex provided loose for contractor installation ( Open Power Unit)
Contractor provides and installs all extended piping, hangers, insulation, etc
Silencer and Flex factory mounted.(Enclosed Power Units)
Factory provides and installs all extended piping. (Enclosed Power Units)
On Enclosed Power Units, silencer can be factory insulated and mounted inside the enclosure providing better
aesthetics and sound attenuation
Block Heaters
Output - 1000 watt to 12000 watt
Input – 120 VAC Single Phase to 480 VAC Three Phase
Factory Mounted on Open Power Units
Factory Mounted and Wired on Enclosed Power Units
Enclosures (Enclosed Power Units)
Weatherproof Skin Tight
Level 1 – Standard (No Sound Attenuation)
Weatherproof and Sound Attenuated Skin Tight
Level 2 – Foam Insulation (Sound Attenuated)
Level 3 – Ultra Quiet Enclosure (Sound Attenuated)
Weatherproof and Sound Attenuated Walk-In
*Available Options on all enclosures include Aluminum Construction,
Motorized Dampeners, Lighting Packages, Distribution Panels, etc.
Emergency Systems
Service Company
Your Partner for
Standard and Optional Accessories
Fuel Systems
Diesel
Double Wall Sub-Base Fuel Tank (24, 48, or 72 Hour Capacity)
Optional Electrical Conduit Stub-Up Area Under MLCB
Double Wall Sub-Base Fuel Day Tank (Remote Pumping Capability)
Remote Day Tank (Remote Pumping Capability)
UL142 and NFPA 30 Compliant
Natural Gas, LP, LP Liquid Withdrawal
Factory provides Fuel Flex, Fuel Solenoid, Y Strainer, and Flow Regulator Valve to operate on 4 oz. to 6 oz. (7-11
inches) of gas pressure.
Vibration Isolation
Pad Style
Spring Style
Spring Seismic Style
Additional Accessories
Trailer Mounted Units for Mobile Applications
UL 2200
Optional Colors (Gold, Tan, Gray Standard)
Extended Warranties (2 year/3000 hour basic)
Emergency Systems
Service Company
Your Partner for
Load Banks
Load Banks are designed to provide electrical loads for testing
Generator Sets and Uninterruptible Power Supplies (UPS). Load
Banks are also used to reduce “Wet Stacking” problems in Diesel
Engines on Backup Generator Sets.
Load Banks are available as:
Permanent
Portable
Radiator Mounted
Reactive
Emergency Systems
Service Company
Your Partner for
Testing
Other Reasons to Test
JCAHO (Joint Commission on Accreditation of Healthcare
Organizations)
Acceptance of NFPA-99-1999 section 3-4.4.1.1(b) calls for the EPS to
be tested a minimum 12 times per year, at intervals no less than 20
days and no more than 40 days.
Emergency Systems
Service Company
Your Partner for
Emissions
All Gaseous fuel generator engines must be EPA certified. Regardless of application
All Diesel fuel generator engines regardless of application, must be EPA Certified and Tier Rated as
follows:
Emergency Standby Power (ESP) – All current Tier 2 and Tier 3 Diesel Generator Sets (in their
applicable horsepower categories) will be compliant through 2015 and beyond
ESP installations are permitted up to 100 hours running time per year for testing and
maintenance.
For applications other than (ESP), such as Load Management, Peak Shaving, Prime Power or
Mobile Rental Power – Tier 4 regulations are in effect.
In order for the engine to comply with Tier 4 regulations, advancements in engine design including
Fuel Injection Systems, Fuel Timing, Electronic Controls, Advanced Turbo Charging and Exhaust
After Treatment will be necessary.
Exhaust After Treatment major technologies include:
Selective Catalytic Reduction (SCR)
Diesel Particulate Filtering (DPF)
Exhaust Gas Recirculation (EGR)
These technologies can add up to 60% to the cost of the engine and will require some type of
maintenance by the customer.
Emergency Systems
Service Company
Your Partner for
Automatic Transfer Switches
Manufacturers:
Asco – GE/Zenith – Cutler Hammer - Russelectric
Styles:
Contactor – Circuit Breaker
Types:
Open Transition - Delayed Transition - Closed Transition
Bypass Isolation
Medium voltage
Service Entrance Rated
Paralleling Switchgear
Static Switchgear
Sizes:
30 to 4000 Amps - 120 to 4160 volts – 2,3, and 4 Pole
Enclosures:
NEMA 1, 3R, 4, 4X, 12
Standard Features:
Time Delays, In-Phase Monitors, Auxiliary Relays, Exerciser, Indicating Lights
Optional Features:
Communications and Scada Systems, Peak Shave, Area Protection,
Load Shed Controls
Emergency Systems
Service Company
Your Partner for
Sales & Technical Assistance
Generator Sizing and Specification
Budgeting
Technical Installation Assistance
- Recommended Options
- Dimensions and Weight
- Location
- Fuel
- Power requirements
- Air Flow
- Exhaust
Pre-Installation Assistance
Operating and Exercising Instruction
Proposal for Continued Planned Maintenance Contract
Thank you for you business and specifying our Generator Sets by
Emergency Systems
Service Company
Your Partner for
Anywhere Reliable Power is Required
Rely On
“Emergency Power System Specialists”
www.emergencysystems-inc.com
Emergency Systems
Service Company
Your Partner for