Privately owned shares company founded at 1972.
ISO 9001:2000 certificate.
The company is engaged in manufacturing Measurement, Monitoring and Control equipment.
Megatron's technical engineering staff has considerable experience in manufacturing, installation
and maintenance of measurement instrumentation
and process controls.
Megatron exports to Europe, North America and
Africa.
MEGATRON
Why choose MEGATRON?
High-quality products
30+ years of experience
Engineering support
Full products information on website
Commitment to ISO 9001:2000 standards
Fast delivery and shipment world wide
Easy installation and maintenance
Two years warranty
English literature
Competitive prices
MEGATRON
MEGATRON Rules
QUALITY
Always do the job on time, at the first time and
all the time.
PRODUCTION
Continually develop new and better solutions,
extensive test series and regular employee
training.
SERVICE
Provide customers with the best combination
of products and support services.
GOALS
Powerful and reliable products at a fair price.
MEGATRON
Company Products
Signal Converters
Controllers
Digital Panel
meters
Multiplexers
Simulators
Timers
Annunciators
Protection units
Set-Point units
Voltage Deviation
Detector
Level Controller
MEGATRON
Signal Converters
MTWT- I
--2Signal
wire Signal
Converters
Converters:
• Input signals:
Current DC/AC, Voltage DC/AC,
Resistance, Temp. Sensors PT-100 /
TC, Pulses etc.
• Output: 4 - 20 mA galvanic isolated.
•
•
Zero and Span calibration.
Compact , DIN rail-mounted enclosure.
Wire Transmitter
with Display
-- 22 Wire
Signal Converter
with Display
•
3.5 digits LCD display.
MITWT- LCD
MEGATRON
Signal Converters
MISCN
- 4 wire Signal Converters:
•
Input: – AC current / voltage
–
DC current / voltage
– Resistance 2 wire or 3 wire.
– Special models :
Average / Square Root / Inverse output.
•
Output: 4÷20mA or 0÷10V
- 2 wire Triple/Dual AC Converters
• include 3 (or 2) isolated channels :
– AC Current input
– Voltage input and
– Frequency of the Voltage;
MVAT
or
– Three Phase AC Current
•
Output: 4÷20mA passive
MEGATRON
Signal Converters
MIFN
- Current to Frequency Converter
• Input signals:
Current / Voltage DC, Temp. Sensor PT-100
• Output:
0-1KHz up to 0-100KHz,
Pulses at frequency proportionally to input signal
- Flow Sensor Converter
MTWT- FLS-D
MTWT- FLS-W
MTWT- H - RTD
-Temp.sensor PT-100 and 2 wire transmitter
MEGATRON
Controllers and Digital Panel Meters
MDI-H
• Input signals:
Current / Voltage AC/DC, Frequency, Resistance,
Temp. Sensor PT-100/TC, Level / Flow sensors
Line of
MDI
MEGATRON
Controllers and Digital Panel Meters
MSCI-4
MSCI-LCD
MIC-1(2)
• Input :
– Current /Voltage AC/ DC
– PT100 Temperature sensor;
– Resistance 3 wire.
• Output :
1 to 4 C/O Contact 220V/5A.
• Zero and Span Potentiometers
MEGATRON
MUX - CDC
Multiplexers
connects 8/16 active or passive analog
inputs (4-20mA or 0-10V or termistors) to
one PLC analog input.
The input is selected by 4 hexadecimal
address lines [ 3 - for 8 inputs].
• Option: – a) inverse logic
– b) input selection by pulses
CLOCK/RESET
• Input: 8/16 analog inputs 4-20mA
(active or passive) are protected against
over current.
MUX - RTD
connects 8 temperature PT-100
sensors (3 wire) to one PLC analog
input.
• The input is selected by 3 binary
address lines
• Output: active 4-20mA.
MEGATRON
MTP-6
Protection units
- Temperature Protection unit
(against overheating electrical motors).
- 6 (or 3) inputs and two output relays
(Alarm and Trip).
• Inputs. option:
RTD or 4-20 mA or 0-10V
• Display: 3.5 digits LCD size 0.5"
and 6 red LED (indicate input deviation)
- Enable a model for panel mounting.
MTP-5
MEGATRON
Protection units
Annunciators
Multi channels monitors based on
microprocessor.
Inputs: dry contact or voltage up to 220V
MMA-190
8 channels
MMA-182
16 channels
MAM-10
10 / 5 channels
Outputs:
• LED for every channel
• 75 db Buzzer and Relay contact for External Horn
MEGATRON
Set-Point units
Protection units
for Monitoring or On/Off controls
• Input:
- Current 4-20 mA DC / Voltage 0-1 VDC;
- AC Current 0-5 A
- PTC Thermistors - Temperature Alarm
• Output:
N.O. / N.C. dry contact 3 A / 220 VAC
MSP / MSP-CAC / MSP-T
The Units protect electronic Equipment
against high voltage (spikes). 2 models:
– MGDF includes 2 fuses and Varistors.
• Fuses: 160mA.
– M1DO Provides a Galvanic Isolate On
/Off signal.
• Output current max: 10mA.
MGDF / M1DO
MEGATRON
Voltage Deviation Detector
Protecting Electronic Instruments.
MVDD
Enable 3 models:
- Input voltage (power) is switched to output.
- Output is relay's contact 220VAC / 5A.
LOW and HI set-points calibration.
- Protecting for Battery loading & unloading
Level Controller for 2 or 3 Electrodes
MCL300
• Use for Pumps operations or Alarms.
• Internal Switch to select Filling or Emptying.
• Electrodes:
Common ( vassal body, if it's metal )
and ON + OFF Electrodes.
• On front Panel 2 LED's and Sensitivity Adj.Pot.
MEGATRON
Timers
Enables selection of time ranges and different
modes of operation:
A - on delay,
B -" pulse, single-shot" (time delay),
D -on delay and "pulse"(off delay),
F- Recycling timer (flasher relay).
MTWT
Simulator
2 operation modes:
• Source: – Current
0-20mA [3 fixed values 4, 12, 20mA]
– Voltage
0 - 10 V [fixed values 2, 6, 10 V]
• Measure: Current 0 - 20 mA /
Voltage 0-10 V DC
MCVS
MEGATRON
How to reach MEGATRON?
www.megatron.co.il
[email protected]
Tel. + 972 – 4 – 841 – 0704
Fax. + 972 – 4 – 841 – 0705
Thanks!