xfp 1-2 loop networkable analogue addressable fire panels
Download
Report
Transcript xfp 1-2 loop networkable analogue addressable fire panels
XFP 1-2 LOOP
NETWORKABLE
ANALOGUE ADDRESSABLE
FIRE PANELS
XFP501E 16 ZONE
1 LOOP FIRE PANEL
Attractive flush or surface
mountable plastic enclosure
No bezel required
Keypad/keyswitch entry
Optional CFP761 network
communications card
LPCB certified to EN54-2/4
Now with an improved user
interface
Easier-to-install enclosure
includes new lid-base hanging
mechanism & drill centre points
XFP501/502 32 ZONE
1/2 LOOP FIRE PANEL
XFP502 32 ZONE
2 LOOP FIRE PANEL
Supplied in a metal enclosure
Optional AFP385 flush bezel
Optional AFP711 network
communications card
Keypad/keyswitch entry
LPCB certified to EN54-2/4
Now with an improved user
interface
KEY XFP RANGE
FEATURES
Third-party certified to EN54 parts 2 & 4 by the LPCB
Compatible with Apollo’s XP95, Discovery and Xplorer protocols
The ability to connect up to 8 XFP main panels (any variant) onto a
two-wire RS485 network. Alternatively up to 8 XFP repeaters can be
connected to a non-networked XFP panel
Two independently programmable conventional sounder circuits
Two programmable inputs
A fault output relay and three programmable relay outputs with
voltage free changeover contacts
A selection of zone dependency/coincidence functions (A, B or C).
A day/night (building occupied/unoccupied) function
An investigation delay period function
Individual sensitivity settings for each device
A phased evacuation facility
An alarm counter (to meet clause 7.13 of EN54-2)
Powerful short circuit protected loop drivers, capable of supporting up
to 40 loop powered 10mA sounders
An integral EN54 switch mode PSU rated @ 185-260V a.c. 50/60Hz
(1.4A on 16 zone, 3A on 32 zone)
Adjustable contamination levels
Earth fault monitoring
Keypad or keyswitch entry to Access Levels 2 and 3
An easy to read, 80 character back-lit display
40 characters of custom text per device
999 event monitoring
Comprehensive test, maintenance & commissioning functions
(including auto-learn loops, monitor a point, test outputs, one man
walk test & loop continuity test)
An intuitive upload-download PC program
NETWORKING
FEATURES
Allows up to eight XFP panels to be interconnected over a two-wire
RS485 network (max. length 1km). Alternatively up to 8 XFP
repeaters can be connected to a non-networked XFP panel
Any variant of master panel (1 loop 16 zone and 1 or 2 loop 32
zone) can be networked together.
All master panels can accept faults, fires, disablements and control
actions from other master panels.
All master panels monitor others for network wiring faults.
Time and date common to all master panels
All master panels require a network communications card.
XFP707 PROGRAMMING
SOFTWARE
Windows 2000/XP/Vista compatible
Intuitive ‘look and learn’ approach to programming
Requires a PC with a 9-way serial port
Kit includes 2m long SAF7070000 programming lead (lead can be
purchased separately)
Comprehensive ‘Help’ files included in software
Free software updates available at www.c-tec.co.uk
Short-form programming/system capability guide included with all
panels
A typical XFP
addressable loop
A typical XFP
network
XFP501E
External View
XFP501E
Internal View
POWER
SUPPLY
PCB
OPTIONAL NETWORK
COMMUNICATION CARD
(mounts at the back of the enclosure)
MAIN CONTROL PCB
XFP501/502
External View
XFP501/502
Internal View
OPTIONAL NETWORK
COMMUNICATION CARD
SWITCH,
INDICATOR &
DISPLAY PCB
MAIN
CONTROL
PCB
POWER SUPPLY
PCB
Access levels
Access Level One - General User
Access Level Two - Authorised User
Access Level Three - Engineer
Access Level 1
General User
Display gives feedback on current system status
Priority is always given to the most important event
Typical conditions are Normal, Fire (inc. 1st-stage), Pre-Alarm
and Fault
Access Level 1
Menu options
Access Level 2
Authorised User
Passcode or keyswitch protected.
Makes active the XFP’s SILENCE/RESOUND SOUNDERS, RESET
and INVESTIGATE CONTROLS
Allows access to the XFP’s authorised user menu options.
Access Level 2
Menu Options
Access Level 3
Engineer
Passcode or keyswitch protected
Makes active the XFP’s SILENCE/RESOUND SOUNDERS,
RESET and INVESTIGATE CONTROLS
Allows access to the XFP’s engineer menu options.
Access Level 3
Menu Options
Programming
Programming
Programming
Programming
CONTACT
DETAILS
CONTEXT PLUS LIMITED
175 Mauldeth Road, Manchester M14 6SG.
Tel: +44 (0) 161 257 2541
Fax: +44 (0) 161 225 8817
E-Mail: [email protected]
Visit our website at www.xportsales.com
© XFP Presentation Rev 3. Although this presentation is current at the time of production, it may be
revised, updated or superseded at a later date. If in doubt, you are advised to check the current
revision number of the presentation by calling our sales desk on +44 (0)1942 322744.