(PowerPoint) Value Proposition for using the S4

Download Report

Transcript (PowerPoint) Value Proposition for using the S4

Enabling Niagara ® for
Legacy Metasys® Installations
Cost effective retrofits with the
S4 Open: BACnet-N2 Router
M3 / M5 Workstation
Ethernet Network
N30 / NCM
Supervisory Controller
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
A generation 2 Metasys ® system is depicted. The S4 Open: BACnet-N2 Router works with any
generation Metasys® supervisory controller that supports N2 field devices
On day one…
• Achieve BACnet compatibility
• Spread out the cost and impact of
upgrading systems over multiple
phases
• Introduce value-added applications
and services
Minimize, avoid, or defer costs
associated with
• Demolition
• New Field Bus Installation
• New Field Devices
• New Mechanical Systems
• Programming Field Devices
• Commissioning
• Construction
www.theS4group.com
©2014 The S4 Group, Inc.
─ Bring comprehensive control of existing legacy
Building Automation Systems into BACnet
─ Introduce Niagara services on day one
─ Co-exist with the legacy Metasys® head end
─ Repair or replace highest risk N2 field gear or
mechanical systems as needed
─ Phased replacement of all Metasys® products
with the field devices of your choice
─ The S4 Open Management Console provides the
user interface for all S4 Open Appliances.
www.theS4group.com
©2014 The S4 Group, Inc.
BACnet
(ETHERNET)
M3 / M5 Workstation
Ethernet Network
BACnet
(ETHERNET)
S4 Open:
BACnet-N2
Router
BACnet
(ETHERNET)
N30 / NCM
Supervisory Controller
Insert the S4 Open appliance
between the Metasys
supervisory controller and field
devices
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
The S4 Open: BACnet-N2 Router is transparent to the Metasys® head end
•
•
•
•
•
•
•
Bidirectional communication: Full read, write, override and release support for all points
The BACnet-N2 Router is transparent to the legacy Metasys® supervisory controller
The BACnet-N2 Router is independent of the Metasys® configuration database
Metasys® head end can participate in BACnet priority array mechanism
Emulates the BACnet Priority Array for N2 points
Emulates Metasys® Override & Release operations for DX-9100
Compatible with any model of the Johnson Controls, Inc. supervisory controller Companion /
Facilitator, NCM, N30, NAE, FX Series
www.theS4group.com
©2014 The S4 Group, Inc.
Auto Configure Wizard Features
• The Configure Wizard discovers all N2 field devices &
publishes points to BACnet IP
• Device Type Templates define point lists for all N2 devices
• Metasys® resource files can be converted to custom device
type templates
• Compatible with all N2 device types including N2 Open,
VND, MIG, VMA and System91
www.theS4group.com
©2014 The S4 Group, Inc.
Each discovered N2 device is
published to BACnet IP as a BACnet
device under a virtual BACnet
network
 The virtual BACnet network number is
configurable
 N2 devices are automatically assigned
BACnet device instance numbers
 All standard BACnet Data Objects are
Supported
www.theS4group.com
The BACnet-N2 Router has a
presence on the local
BACnet Network
 Device ID and Network can be
set and easily modified via the
Management Console
©2014 The S4 Group, Inc.


Performance and Error monitoring
tools are built into the S4 Open
Appliances
The N2 bus operates at 9600 baud halfduplex



This can’t be changed!
The S4 Open appliance protects the N2 bus
from becoming overwhelmed with requests
from high speed Ethernet interfaces
JCI Engineering Guidelines


N30 – 50 N2 devices
NCM – 100 N2 devices
www.theS4group.com
©2014 The S4 Group, Inc.
StruxureWare
Niagara
Environment
Environment
BACnet
(ETHERNET)
BACnet
(ETHERNET)
M3 / M5 Workstation
Ethernet Network
N30 / NCM
Supervisory Controller
BACnet
(ETHERNET)
BACnet
(ETHERNET)
Install the BACnet Operator
Workstation
S4 Open
BACnet-N2 Router
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
Migration Strategies
www.theS4group.com
©2014 The S4 Group, Inc.
 The S4 Open: BACnet N2 Router minimizes
the day one cost of doing a retrofit of legacy
Metasys® installations and facilitates the
long term migration away from legacy N2
devices.
 The S4 Open: BACnet N2 Router provides
the enabling technology to introduce
Niagara services and features to legacy
Metasys® N2 installations
 The Niagara Framework™ adds advanced
graphics, analytical, and management
capabilities on day one
 Niagara provides a unified user experience
for all building, environmental, and energy
management systems
www.theS4group.com
©2014 The S4 Group, Inc.
Phase Out Legacy Metasys© Head End
M3 / M5 Workstation
StruxureWare
Niagara
Environment
Environment
Ethernet Network
N30 / NCM
Supervisory Controller
S4 Open:
BACnet-N2
Router
N2 Protocol
(RS-485)
VMA Device
(N2B
Protocol)
DX-9100
(System 91
Protocol)
TEC2145-2
(N2 Open
Protocol)
MS-MIG3120
(Metasys
Integrator)
TCS Basys
(VND Device)
Downloadable Case Studies:
Why is it so cold in here?
Hospital integration project
The Jackson Federal Building in
Seattle, Washington
Project includes smoke control applications
FDA Validated Facility
Pharmaceutical manufacturer BMS upgrade
Additional case studies are
available here
www.theS4group.com
©2014 The S4 Group, Inc.
• Migration to a pure BACnet
environment
• Generate customer loyalty
• Low entry cost
• Flexible migration strategy
• Minimal impact on building
occupants
• Minimal downtime
• Expanded market opportunities
• Competitive edge
www.theS4group.com
©2014 The S4 Group, Inc.
For more information, please visit
our website
www.thes4group.com
Or contact Steve Jones, Managing
Partner
(801) 621-1970
[email protected]
© 2014 The S4 Group, Inc.