G4 Control and Management Solution for Data

Download Report

Transcript G4 Control and Management Solution for Data

G4
Control and Management Solution for DataCenters and Computer Rooms
The G4
•
•
Perfect “All Built In” solution for control, management and
monitoring
computer rooms and data-centers.
An unique integrated solution that ensures full control of
equipments,
real time detection of faults and immediate notifications
to users.
•
Works on LAN/WAN network,
•
Includes GSM modem
Features
• Accepts input from up to 5 temperature sensors.
• 8 inputs dry contacts.
• 4 outputs dry contacts.
• RS232 serial connection for power devices (UPS / rectifiers).
• Ethernet line interface 10/100 Base auto detect. Network protocols
:
TCP/IP, UDP/IP, HTTP, SNMP v2, DNS, PPP, SMTP,
TELNET,MODBUS client .
• Internal cellular modem support GPRS/GSM – Dual or Quad band.
•Antenna and SIM card connection.
G4 main screen
Change your point of view
Server room
Smoke detector
SNMP trap
Air condition start operation
Air Condition stop operation
GPRS/SMS Control
and Notification
Motion detector
Shutdown
Servers
AC Fail
Wake-up
Servers
AC Recovered
Alarm
Door / Window open
High temperature
Leak detection
and notification
Control and monitor of IT equipments
•
Reading and analysis information through SNMP of IT equipments like:
servers, switches, printers, …
•
Features analyzed: CPU load, virtual and physical memory used, used
and free space capacity for all SNMP (RFC2790 ) supported equipments.
•
Check Availability of equipment by ping requests.
•
Automatic shutdown up to 32 servers in UPS AC failure or a critical event
defined by user –for more than 32 need additional Gamatronic’s software
called “PSM”.
•
Wake up servers in the way of “WAKE ON LAN” - (Bios configuration) and
wake with delay availability.
•
SNMP trap to management centers use SNMP manager like:
What‘s Up, HP Open View, CA.
•
SNMP restriction to set/get by community and IP – G4 may use as a
server/client SNMP.
IT monitoring screen
IT Monitoring - Configuration Screen
Monitoring power systems
• G4 performs real time verification of
Gamatronic and other UPS’s and power
systems manufacturers.
• immediate alarm notification such as:
AC fail, Low battery, on Battery… .
•
G4 notifies and operates accordingly:
=> Shutdown server for prevent damage to
IT equipments and data bases,
=>send SMS/EMAIL/SNMP trap to relevant
users.
POWER + monitoring screen
POWER + monitoring screen
Dry contacts
•
Work with relays that define the status to normally open/close
•
G4 will detect every changes of these states and immediately notify users .
DRY IN:
•
•
8 dry contacts inputs to receive alarms from different sensors such as:
Air conditions, doors, smoke detectors, fire detector ,flood and more.
Contacts can be enable/disable in certain hour during the day according to
user preferences.
DRY OUT:
•
4 dry contacts outputs for remote activation of different devices like:
Back up air condition, lamp, alarm, gates and more.
•
Contacts can be activated automatically in one of following cases:
1) status’ change of a certain dry contact IN.
2) High temperature alarm.
3) IT alarm.
4) UPS alarm.
Dry contacts screens
Environment Temperature
•
•
G4 can monitor up to 5 temperature measurements sensors (one
is
provided by default).
All sensors can be configured with high/low limit ,description name
and
Hysteresis that prevent falsehood notifications when the sensor is
in the
limit between the normal and critical temperature.
Environment temperature – main screen
Control via SMS
•
The G4 can send notifications up to 10 mobile phone numbers. These numbers may also
have a full control on the unit.
•
A “status” SMS command reply a short answer of Fail/OK on following parameters:
IT monitoring, environment, dry contacts, UPS .
•
All critical commands will require SMS password and a flag authorization in the WEB
interface – near all phone number ,
•
user can mark the number he wants to authorize full control option.
•
User can choose to receive a status notification from G4 from time to time.
Critical commands example:
•
Shutdown server, wake up server, change dry contact status (open, close, pulse),
get the G4’s IP.
The Control via SMS
Additional features
•
Hardware is not dependent to an external server.
•
Built- In AJAX based web interface - enables accessibility thru every remote
internet browser.
•
Event group- user can define a group of events he wants and refer them to
a particular phone target.
•
Internal 256 event log available through web server or SNMP.
•
GPRS communication: where the LAN/WAN network isn’t accessible.
•
Can operates with the Gamatronic “PSM AC UNIVERSAL” software to
increase the shutdown target to more than 32 devices.
•
Can operates with Gamatronic “GEMSI software” for monitoring several G4
units and other UPS models.
GeMSi Software - Main screen
GeMSi main
screen, shows
real time
status of all
regions and
sites, alarm
counter and
direct
connection to
alarmed unit.