EX-PRESS® Device

Download Report

Transcript EX-PRESS® Device

Glaucoma Surgery 2011:
Why am I Still Doing a
Trabeculectomy?
Garry P Condon, MD
Associate Professor Ophthalmology
Drexel University College of Medicine
Chairman Dept Ophthalmology
Allegheny General Hospital
Pittsburgh PA
EXP11749SK
EX-PRESS® Device Brief Statement
CAUTION: Federal law restricts this device to sale by or on the order of a physician.
INDICATION: The EX-PRESS® Glaucoma Filtration Device is intended to reduce intraocular pressure in glaucoma patients
where medical and conventional surgical treatments have failed.
GUIDANCE REGARDING THE SELECTION OF THE APPROPRIATE VERSION: Prior clinical studies were not designed to
compare between the various versions of the EX-PRESS® Glaucoma Filtration Device. The selection of the appropriate
version is according to the doctor's discretion.
CONTRAINDICATIONS: The use of this device is contraindicated if one or more of the following conditions exist:
· Presence of ocular disease such as uveitis, ocular infection, severe dry eye, severe blepharitis.
· Pre-existing ocular or systemic pathology that, in the opinion of the surgeon, is likely to cause postoperative
complications following implantation of the device.
· Patients diagnosed with angle closure glaucoma.
WARNINGS/PRECAUTIONS:
· The surgeon should be familiar with the instructions for use.
· The integrity of the package should be examined prior to use and the device should not be used if the package is
damaged and sterility is compromised.
· This device is for single use only.
· MRI of the head is permitted, however not recommended, in the first two weeks post implantation.
ATTENTION: Reference the Directions for Use labeling for a complete listing of indications, warnings, precautions,
complications and adverse events.
EXP11749SK
Why do I still do some form of
Trabeculectomy?
Experience
…stood the test of time
It works
Can repeat it
Doing it better
EXP11749SK
Collaborative Initial Glaucoma Treatment
Study (CIGTS)
• 465 trabeculectomies (300 patients)
• Pre-op IOP: 27 mmHg
• Post-op IOP: 15 mmHg
– 44% reduction
• 5 years follow-up
Lichter PR, Musch DC, Gillespie BW, et al; CIGTS Study Group. Ophthalmology. 2001;
EXP11749SK
What counts in glaucoma
surgery…
“Is Scoring With Efficacy”
IOP Reduction of
30% and More…
EXP11749SK
Trab: Nothing else stacks up!
Failed Contenders
Viscocanalostomy
Deep sclerectomy
Deep sclerectomy with
Aquaflow
Sinusotomy
Thermal sclerostomy
Iridencleisis
Laser sclerostomy
Internal sclerectomy
Cyclodialysis
Trabeculotomy
Goniotomy
Cyclophotocoagulation
Transscleral
Endoscopic
EXP11749SK
Trab’s Two Biggest Contenders:
Tube Shunts
Canaloplasty
EXP11749SK
Trabeculectomy
…a life after TVT?
Tube vs Trab Study
A new Star?
Or tubes just on a Power Play?
EXP11749SK
Trabeculectomy
…a life after TVT?
• Study limitations
– Preliminary data
– More data being published
• 5yr results presented at AGS
EXP11749SK
TUBE VS TRAB:
SOME BOOTH COMMENTARY…
Listen to me...
I’m a Canadian!
EXP11749SK
TVT Probability of Failure
30.7%
p=
0.010
15.1%
Gedde SJ et al. TVT 3 yr follow up, AJO 2009
EXP11749SK
TVT Probability of Failure
30.7%
p=
0.010
15.1%
Gedde SJ et al. TVT 3 yr follow up, AJO 2009
EXP11749SK
The Fight Wasn’t Fair!
While all eyes were good candidates for a tube
….Failed trab eyes not good cases for another
trab
EXP11749SK
And yet…The Overtime Period!
Trab was ‘effective’ in 70% of cases
And on fewer meds!
… available options down the road
Needling / revision
Trab again!
Gedde SJ et al. TVT 3 yr follow up, AJO 2009
EXP11749SK
TVT: The Off Sides
Tube first … Big Bloody Operation
One Good Shot
Trab after a tube??
EXP11749SK
TVT: The Penalty Box!
New motility problems in tube group 10%
Gedde SJ et al. TVT 3 yr follow up, AJO 2009
EXP11749SK
Replay… what can we say?
• Do TVT results to date favor tubes?
• Yes – In patients with previous conj surgery
But…
• In Clear corneal pseudophakes?
• In Primary glaucoma surgery??
We just don’t know.
EXP11749SK
Canaloplasty?
Best study: 89 patients 3-year F/U
Pre-op IOP: 23.5 mmHg
Post-op IOP:15.5 mmHg
34% reduction
Lewis, RA, et al, Canaloplasty: 3 yr results, Journal of Cataract and Refractive Surgery 2011
EXP11749SK
Canaloplasty: Problems
No independent data…
Uncontrolled, non-randomized study
from i-Science
And…
15% of cases surgeons couldn’t
complete the operation!!
Find the canal
Pass the Microcatheter
Lewis, RA, et al, Canaloplasty: 3 yr results, Journal of Cataract and Refractive Surgery 2011
EXP11749SK
Canaloplasty vs Trabeculectomy
Sponsor
Patients
(#)
F/U (yrs)
i-Science CIGTS
NIH
89
465
3
IOP
34%
reduction
5
44%
Lewis, RA, et al, Canaloplasty: 3 yr results, Journal of Cataract and Refractive Surgery 2011
Lichter PR, Musch DC, Gillespie BW, et al; CIGTS Study Group. Ophthalmology. 2001;
EXP11749SK
So for that super-LOW IOP
In Primary Virgin Eyes
For now…
EXP11749SK
Trabeculectomy is the Gold Standard!
Trab…
The
Winning
play!!!
EXP11749SK
…but live with this!?
EXP11749SK
…and this
EXP11749SK
… We CAN DO IT BETTER!
Surgery 1 year apart
OS limbal based
OD fornix based
Fornix based flap
Broader MM-C application
Bullet-proof Conj closure
EXP11749SK
Mastering water-tight closure
Condon Conj Closure video: Eyetube.net
EXP11749SK
EX-PRESS® Device Indication
The EX-PRESS® Glaucoma Filtration Device
is intended to reduce intraocular pressure in
glaucoma patients where medical and
conventional surgical treatments (SLT/ALT)
have failed.
EXP11749SK
More precision?
More control?
EX-PRESS® device under scleral flap
Maris, Ishida and Netland. J Glaucoma, Jan 2007
Hearndon and Marzette. AGS 2008
EXP11749SK
Trab-what I hated
EXP11749SK
EX-PRESS® device titled 220
EXP11749SK
EX-PRESS® Device: P-50
EXP11749SK
EX-PRESS® device P-50 DETAIL
EXP11749SK
My Flap Technique
Conj flap technique:
LimbusBased
<2001
FornixBased
>2001
Number of consec eyes:
(min 4 wk f/up)
107
199
wound leaks req surg repair:
2
2
wound leaks req surg repair %
1.9
1.0
Video:
‘Closing the Conjunctival Flap’
www.Eyetube.net
EXP11749SK
1 mo
1 yr
EXP11749SK
Assessment of Bleb Morphology and Postoperative Outcomes After
EX-PRESS® device Versus Trabeculectomy
(Good & Kahook, AJO 2011)
• Retrospective Consecutive Case Control
Series
• Seventy Patients (n=35 each group) with
Mean of ~28 months of follow up
• Also assessed time to visual recovery
EXP11749SK
Post-operative Outcomes After
EX-PRESS® device Versus Trabeculectomy
Final IOP decreased by 45.15% and 48.45% from baseline
in the EX-PRESS® device and Trabeculectomy groups respectively
(p=0.209)
EXP11749SK
Assessment of Visual Recovery
EX-PRESS® device Versus Trabeculectomy
* Best Corrected
EXP11749SK
EX-PRESS® Glaucoma
Filtration Device
Remarkably Biocompatible
A Nyska, Y. Glovinsky, M. Belkin, and Y. Epstein. Biocompatibility of
the EX-PRESS® miniature glaucoma drainage implant. J Glaucoma.
2003 Jun; 12(3):275-80
EXP11749SK
De Feo etal. 2009
• 2 yr postop EX-PRESS® device in one eye
(postmortem)
• No difference in corneal endothelial cell density
between the two eyes
F. De Feo, S. Jacobson, A Nyska, P. Pagani, C.E Traverso. Histological Biocompatibility of a Stainless Steel Miniature
Glaucoma Drainage Device in Humans: A Case Report. Toxicologic Pathology, 37: 512-516, 2009
EXP11749SK
We can do BETTER than this!
EXP11749SK
And this…
EXP11749SK
Let’s raise the bar…
No… Let’s Raise a Glass at the Bar!
More correct and effective standard surgery
New approaches to enhance current techniques
Smoother more favorable outcomes
EXP11749SK
Thank-you
EXP11749SK