Transcript Document

AK
AK
IRRInet-M
IRRInet-ACE
Product Introduction
Presented By: AK
Updated: Dec 2, 2007
AK
AK
Upon completion of this presentation,
you should be able to:
Understand all HW options
Understand all Configuration options
Understand Migration of new HW into
legacy systems
Understand all Models and Options
Understand all about on-site
programming tool (Pocket-PC)
AK
AK
IRRInet-M - General View
IRRInet-M AC
Commonality
24VAC Power In (AC)
Inputs/Outputs
- 12 Outputs, 4 DI on the Basic
board
- 12 Outputs, 4 DI on the Expansion
board
12VDC Power In
Relay outputs for
Solenoids: 24V AC or,
External power
connection
Communication Ports:
- RS232/485
- RS232
- Radio/Line
IRRInet-M DC
Power:
- 12V DC in
- 5, 7.5, 9.5, 12V DC (2Amp) Power
out for portable radio
12VDC Power In
20 LED for Status display
DC Latch Solenoids
activated by 3300 µF
35 VDC capacitor
1 Push button (various functions)
AK
AK
IRRInet-M – Master/Slave configuration (1)
IRRInet-M supports 3 modes of operations
RTU (loaded with IRRI 7.0 Master)
Performing all irrigation functions (IRRIV Capabilities)
Reporting to the ICC, Via the MDLC Cloud
Stand Alone (loaded with IRRI 7.0 Master)
Performing all irrigation functions as a stand-alone unit
when the system is installed without an ICC
Remote I/O (loaded with IRRI 7.0 Slave)
Serving as a Distributed I/O for another unit (the Master)
Please note!
In the PAST whenever using
SCORPIO or IRRIcom, it was
ALWAYS as a Remote I/O to a
Master IRRInet
This is NOT a MUST
anymore!
Use the Slave option
only when needed!!
AK
AK
IRRInet-M – Master/Slave configuration (2)
ICC
MDLC
FIU
Master
Slave
Master
Loaded with IRRIV 7.0 Slave
Master
Slave
Loaded with IRRIV 7.0 Master
AK
IRRInet-M – RS485 Port Options
AK
MDLC
ICC
FIU
D
RS485
Master
MDLC Connection to ICC
Master
RS485
RS485
A
Slave
RS485
C
B
Remote I/O (Slave) to
IRRInet-ACE Master
Master
Slave
Operating Piccolo XR’s
Remote I/O (Slave) to
IRRInet-M Master
PIU
AK
IRRInet-M – RS232 Port Options
AK
Pocket PC (ARM)
F
RS232
MDLC
RS232
ICC
A
IRRInet-M
FIU
E
RS232
Master
MDLC Connection to ICC
Master
RS232
RS232
B
Slave
RS232
D
C
Remote I/O (Slave) to
IRRInet-ACE Master
Master
Slave
Operating Piccolo XR’s
Remote I/O (Slave) to
IRRInet-M Master
PIU
AK
IRRInet-M – Radio Port Options (it is Radio or Line, Configurable)
C and D may not coexist with the same
unit
MDLC
RS232
AK
ICC
IRRInet-M
FIU
A
E
Master
Radio Link, MDLC Cloud
Master/Slave Connection to
New and/or Old remotes
Master
B
Slave
D
C
Remote I/O (Slave) to
IRRInet-ACE Master
Remote I/O (Slave) to
IRRInet-M Master
Slave
You may configure
the IRRInet-M
To “Talk” PRIS
Legacy
Scorpio/IRRIcom
Impact
AK
IRRInet-M – Line Port Options (it is Radio or Line, Configurable)
AK
Line
MDLC
RS232
ICC
IRRInet-M
FIU
A
C
Master
Line Link, MDLC Cloud
Line
Line
Master/Slave Connection to
another IRRInet-M
B
Master
Master to ICC
Slave
Remote I/O (Slave) to
IRRInet-M Master
AK
AK
Q: I need to add a new device to a network that already has Scorpio(s) or
IRRIcom(s). What do I do?
A: Below…
FIU
ICC
MDLC
Please note!
IRRInet
XL/XM
Load IRRIV Master for direct
connection to ICC or,
Load IRRIV Slave with PRIS
protocol to report to the legacy
IRRInet-XL/XM
IRRIcom
Scorpio
IRRInet-M
AK
AK
Q: When should I use IRRInet-M and when should I use IRRInet-ACE?
A: Below…
MDLC
?
FIU
IRRInet-ACE
IRRInet-M
ICC
This release will deliver the following for the IRRInet-ACE
•
•
•
IRRIV 7.X (Master) running on the IRRInet-ACE
Usage of current released I/O Modules
Support on-site programming, using Pocket PC machine (ARM based)
It takes a whole System Planner to explain all considerations: but…)
•
Communication Media
•
•
•
•
Number of needed Ports (only 3 on IRRInet-M, 5 on IRRInet-ACE
I/O specification
•
•
•
DC solenoids, only on IRRInet-M
Analog I/O only on IRRInet-ACE
I/O count
•
•
larger variety on IRRInet-ACE
Line needed? only on IRRInet-M
Up to 24 Outputs and 8 inputs on IRRInet-M, up to 8 Modules on IRRInet-ACE
RUNGS needed? Only on IRRInet-ACE
AK
AK
Q: I have an IRRInet XL/XM I need to replace, or add. What do I do?
A: Below…
FIU
ICC
MDLC
Option B
IRRInet-ACE
IRRInet
XL/XM
Master
IRRInet-M
Option A
AK
Q: I need to add IRRInet-ACE, but this unit MUST operate the legacy Scorpio,
IRRIcom or Impact. What do I do?
A: Below…
AK
Please note!
MDLC
The IRRInet-M will route the PRIS
commands to the legacy units.
It may serve, at the same time, as
a slave as well.
FIU
ICC
IRRInet-ACE
RS485
IRRInet
XL/XM
IRRInet-M
Router
Slave
Impact
Scorpio
IRRIcom
AK
Q: In fact, the IRRInet-ACE does not have dedicated Modules for Irrigation, So…?
A: Below…
FIU
MDLC
ICC
IRRInet-ACE
RS485
IRRInet-M
A. Connect IRRInet-M to the
IRRInet-ACE to serve as its I/O
board
(AC and/or DC)
B. Use the ACE’s Relay I/O
Module for AC solenoids,
or any other ACE original
I/O Module
AK
AK
AK
IRRInet-M AC User’s Connections
Please note!
The relays may operate the
solenoids using external WET
Power (programmable).
Up to 60 VDC or 30 VAC
1A per output, 6 Amp Total
Over Current Detection
(10A)
1
DO1
1
DO13
2
DO2
2
DO14
3
DO3
3
DO15
4
DO4
4
DO16
5
DO5
5
DO17
6
DO6
6
DO18
7
DO7
7
DO19
8
DO8
8
DO20
9
DO9
9
DO21
10
DO10
10
DO22
1
DO11
1
DO23
2
DO12
2
DO24
3
COM
OUT
3
COM
OUT
4
DO
WET
4
DO
WET
5
USER
PGND
5
USER
PGND
6
DI1
6
DI5
7
DI2
7
DI6
8
DI3
8
DI7
9
DI4
9
DI8
10
COM
DI
10
COM
DI
For Radio Communication
For Radio Power: 5, 7.5, 9.5,
12 VDC, 2 Amp
Programmable
Port 3 for Line
Communication
12 V DC (Optional): To
operate the Logic Board
24 VAC for Logic Board
and I/O operation
AK
AK
IRRInet-M DC User’s Connections
1
DO1
1
DO13
2
DO2
2
DO14
Capacitor- 3300 µF 35 VDC
3
DO3
3
DO15
Discharge Voltage – 4 to 35
VDC (Configurable)
4
DO4
4
DO16
5
DO5
5
DO17
6
DO6
6
DO18
7
COM
OUT
7
COM
OUT
8
DO7
8
DO19
9
DO8
9
DO20
10
DO9
10
DO21
1
DO10
1
DO22
2
DO11
2
DO23
3
DO12
3
DO24
4
COM
OUT
4
COM
OUT
5
USER
PGND
5
USER
PGND
6
DI1
6
DI5
7
DI2
7
DI6
8
DI3
8
DI7
9
DI4
9
DI8
10
COM
DI
10
COM
DI
Pulse Width: up to
120mSec
Open Loop and Short
Detection
For Radio Communication
For Radio Power: 5, 7.5, 9.5,
12 VDC, 2 Amp
Programmable
Port 3 for Line
Communication
12 V DC for Logic board
and Solenoids operation
AK
AK
IRRInet-M – New Front Label
• New Design
• 20 LED's for: (detailed explanation in the Manual)
• CPU Status
• I/O Status
• Error Logger Status
AK
AK
IRRInet-M – Push Button
• Various Functions
• Reset (and download SW)
• Test
• Scroll Page for LED Display
AK
AK
SW Features
IRRInet-M supports 3 modes of operations
RTU (loaded with IRRI 7.0 Master)
Performing all irrigation functions (IRRIV Capabilities)
Reporting to the ICC, Via the MDLC Cloud
Stand Alone (loaded with IRRI 7.0 Master)
Performing all irrigation functions as a stand-alone unit
when the system is installed without an ICC
Remote I/O (loaded with IRRI 7.0 Slave)
Serving as a Distributed I/O for another unit (the Master)
Capacity
250 Outputs
250 Inputs
125 Main Lines
200 Programs
200 Groups
50 Fertilizer Pumps
50 Filter Batteries
User Configuration
Solenoid Operation Voltage (IRRInet-M DC)
Radio Operation Power (AC and DC)
External/Internal Relay’s Power Switching (IRRInet-M AC)
AK
2 Modes of operation:
Terminal
On-Site Programming SW
(Pocket PC Connectivity (ARM Only)
Stand-Alone
Windows Mobile 5.X compatible
Product
IRRIcom
IRRInetXM
IRRInetXL
IRRInet-M
IRRInet-ACE
Pocket PC
Connection
to…
NO
Running
IRRIV
5.X
Running
IRRIV
5.X
Running
IRRIV
7.X (Master only)
Running
IRRIV
7.X (Master)
Please
note!
F4050A – on-site
Programming SW, for
Pocket PC.
AK
AK
AK
Configuration Tool
STS
The new STS (ACE3600 Configuration Tool), will be used to configure the IRRInet-M and the IRRInet-ACE
STS Software
AK
IRRInet-M Models and Options (1)
IRRInet-M DC
F4960A
IRRInet-M DC no Radio
F4964A
IRRInet-M DC with UHF Portable Radio
F4963A
IRRInet-M DC with VHF Portable Radio
IRRInet-M AC
F4860A
IRRInet-M AC no Radio
F4864A
IRRInet-M AC with UHF portable Radio
F4863A
IRRInet-M AC with VHF Portable Radio
AK
Please note!
Entering Frequency is
Mandatory for models
W/Radio
AK
IRRInet-M Models and Options (2)
For VHF Radio
V951AM VHF Radio for N.A (HT750)
For UHF Radio
V951AN UHF Radio for N.A (HT750)
V803
V314AR
Add DC 4/12 I/O Expansion
V260AM
Add AC 4/12 I/O Expansion
V020AC
DIN Rail Installation Kit
Please
note!
The AC Expansion fits
both the IRRInet-M AC
and DC main boards
Load IRRIV 7.0 Master
Application
V804
Load IRRIV 7.0 Slave
Application
AK
AK
IRRInet-ACE Models and Options
For IRRInet-ACE use ACE3600 catalog pages, and…
V450 to order IRRInet-ACE 3610 CPU (this CPU is identified with the Irrigation)
V451 to order IRRInet-ACE 3640 CPU (this CPU is identified with the Irrigation)
V805 ask factory to load IRRIV 7.X application (Master) into the CPU
AK
AK
New deliverables summary
IRRInet-M
IRRInet-M AC
IRRInet-M DC
IRRInet-M AC Expansion Board
IRRInet-M DC Expansion Board
IRRIV 7.X for IRRInet-M Master
IRRIV 7.X for IRRInet-M Slave
IRRInet-ACE
IRRIV 7.X for IRRInet-ACE Master
STS – New version supporting Irrigation
ICC – New version 14.X (supporting new deliverables)
On-Site Programming SW (for Pocket PC)
AK
AK
AK
END
Thank YOU!