Transcript GS3055-I

GS3055-I Installation
Process
GS3055-I Overview
The GS3055-I is:
1.
A universal wireless alarm communicator that can be used in a backup or
primary role.
2.
A device which connects the alarm control panel to the GSM network and reports
alarm signals directly to a monitoring central station receiver (Sur-Gard System
III/ System II).
3.
A digital transmitter which provides full reporting from any control panel that
communicates using Contact ID format.
CONFIDENTIAL
GS3055-I Service Provider
What is CONNECT 24?
•
CONNECT 24 is the GS3055-I service provider
•
CONNECT 24 provides the automated telephone activation system for the activation of GS3055-I units
(GVRU, Voice Response Unit)
•
CONNECT 24 provides web-user interface support for the programming of GS3055-I units
•
CONNECT 24 provides account administration, billing and rate plans to GS3055-I customers
CONFIDENTIAL
GS3055-I Enrolment Steps
In order to properly enrol a GS3055-I unit you must follow these steps :
STEP 1 – Activate your SIM card with Connect 24*
STEP 2 – Initialize the GS3055-I with Connect 24
STEP 3 – Determine best signal strength location
STEP 4 - Connect the GS3055-I to the control panel
STEP 5 - Program the control panel to use Contact ID format
STEP 6 – Test the GS3055-I
Note: GS3055-I unit must be powered down for STEPS 1 and 2
CONFIDENTIAL
GS3055-I SIM Card Activation (GVRU)
SIM Card Activations must be activated with Connect 24 prior to use. Please call the
VRU at least 24 hours prior to installation. To activate a SIM Card, you will need the
following information:
1.
Installer’s ID Number: It identifies each installer listed on the Dealer Enrolment Form
2.
Installer’s PIN Number: It identifies each installer with a 4 digit PIN number
3.
The SIM Card Number: (Subscriber Identity Module), 19-20 digits located on SIM Card
Note: Only authorized dealers can activate a SIM Card with CONNECT 24
CONFIDENTIAL
GS3055-I Initialization (GVRU)
To initialize a GS3055-I unit, you will need the following information:
1.
Profile Number: It represents the Central Station Receiver IP address and Rate Plan
2.
Installer’s ID Number: It identifies each installer listed on the Dealer Enrolment Form
3.
Installer’s PIN Number: it identifies each installer with a 4 digit PIN number
4.
The Central Station Account Number: Account number to be transmitted to the Central
Station Receiver
5.
The SIM Card Number: (Subscriber Identity Module), 19-20 digits located on SIM Card
6.
The DNIS Number: (Dialled Number Information Service), Check your work order
•
Test transmission selection: daily, weekly or monthly
•
Determine if GS3055-I unit is the primary or backup communicator
•
Determine the type of installation Residential or Commercial
Note: Only authorized dealers can initialize a GS3055-I with CONNECT 24
CONFIDENTIAL
GS3055-I Signal Strength Test
To test the signal strength of a GS3055-I, you need:
1.
The antenna must be connected to the GS3055-I
2.
The SIM Card must be inserted into the GS3055-I
3.
The Battery must be connected to the GS3055-I
The Signal Strength levels on GS3055-I are:
1.
Excellent Signal Strength = GREEN LEDS 3 and 4
2.
Good Signal Strength = GREEN LED 4
3.
Poor Signal Strength = GREEN LED 4 (Flashing)
4.
No signal Strength = OFF
For a proper installation, the GS3055-I must have
a Good Signal Strength
CONFIDENTIAL
GS3055-I – Telephone Wiring (Back-up Mode)
To Power Supply
From RJ-31X
Demarcation
To Premise
Telephones
CONFIDENTIAL
GS3055-I Control Panel Programming
Panel programming consist of:





Program any phone number (at least 1 digit)
Program the corresponding account number
Program the panel’s format as Contact ID
Program Reporting codes or activate automatic reporting
option
Enable the phone line communicator
CONFIDENTIAL
GS3055-I Testing
To test a GS3055-I unit, follow the next steps:
1.
Disconnect the telephone line from the TIP and RING terminals on the GS3055-I unit
2.
Verify that LED 2 (YELLOW) is ON. This indicates that the unit is in GSM mode
3.
Connect a voltmeter to R1 and T1 on the GS3055-I unit, the voltage reading should be around
34.5Vdc (dial tone)
4.
Arm the control panel and violate a zone, so that the panel attempts to report the event
5.
Connect a butset to RING and TIP on the control panel to verify that the control panel is
communicating
CONFIDENTIAL
GS3055-I – Testing
To Power Supply
To Premise
Telephones
CONFIDENTIAL
GS3055-I
Questions?
CONFIDENTIAL